Notifications
You must be signed in to change notification settings - Fork 6
server dell idrac
- There were a number of bad firmware payloads for Dell iDRACs which caused them to lock-up after several 100 days of running. In extreme cases, the iDRAC would also prevent the server running properly. A server in this state will often show odd CPU runtimes in top; e.g.
[root@node07(tde-hpc1) ~]# top
top - 16:28:23 up 4:22, 1 user, load average: 0.03, 0.01, 0.00
Tasks: 373 total, 1 running, 372 sleeping, 0 stopped, 0 zombie
Cpu(s): 0.0%us, 0.0%sy, 0.0%ni,100.0%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
Mem: 132112272k total, 1201896k used, 130910376k free, 35908k buffers
Swap: 33554424k total, 0k used, 33554424k free, 215336k cached
PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND
8035 postfix 20 0 77684 3244 2400 S 100.0 0.0 1741127h pickup
8884 root 20 0 107m 4176 3148 S 100.0 0.0 5139105h sshd
8973 root 20 0 13436 1404 876 R 100.0 0.0 82982,17 top
1 root 20 0 25696 1636 1292 S 0.0 0.0 9256388h init
2 root 20 0 0 0 0 S 0.0 0.0 750485,50 kthreadd
The process for fixing this is as follows:
-
Disable GridEngine Queue
qmod -d *@node00
-
Wait until node responds to
power node00 status
-
Logon to node and run
shutdown -h 1
and wait. -
Node probably will not turn off by itself and will probably require the power to be forced off - use the
power node00 off
command. -
Wait 2 minutes and ensure that the node has turned off by using
power node00 status
-
Power node back on with
power node00 on
and wait for node to boot. Note that using thereset
power option will not fix the state! -
Wait for node to boot, login to the node and start a
screen
session. -
Run the BMC Firmware Update Utility - usually named something like
ESM_Firmware_3F4WV_LN_1.66.65_A00.BIN
-
Wait for update to complete
-
Reboot node
-
Connect to node serial console
console node00
-
Ensure that System Lifecycle Controller is not in "Recovery" status and causing boot errors.
-
Wait for node to restart
-
SSH to node and open
screen
session. -
Run BIOS update utility - usually named something like
BIOS-xxxxx.BIN
-
Allow system to Reboot
-
Reconnect to console after node has started rebooting
-
Ensure Flash completes
-
Ensure Lifecycle Controller is still not in Recovery status and causing boot problems.
-
Ensure BIOS & BMC revisions are correct in
dmidecode
and by starting IPMI service and runningipmitool mc info
-
Re-enable queues on node
qmod -e *@node00