-
Notifications
You must be signed in to change notification settings - Fork 0
tmpbci/jBMM
Folders and files
Name | Name | Last commit message | Last commit date | |
---|---|---|---|---|
Repository files navigation
jBMM by Samneurohack samneurohack @ gmail com http://www.tmplab.org/wiki/index.php/Brain_Computer_Interface Source code of "Basic Mind Music", the musical part of a tmpbci/La paillasse installation at Macval (museum of contemporary art in France) on May 22nd 2011. High Gamma Brainwaves values are converted to sound spectrum thanks to a generative Pure Data Patch. jBMM is alpha state, working correctly but definately not bulletproof : follow the instructions. Next versions won't need PureData and will be simplier to work with. REQUIREMENTS INSTALL USAGE DISPLAYED MESSAGES REQUIREMENTS Rebol language (around 1 Mo) and ThinkGearconnector, MacOS or Windows. INSTALL Install Rebol view 2.7.x, *note that rebol 3 is not supported* : http://www.rebol.com/download-view.html OS X: you may want to copy rebol in your PATH : cd youreboldownloadirectory sudo cp rebol /usr/local/bin/ Install Thinkgear Connector program from Mindset Developper Tools : http://store.neurosky.com/collections/development The Mindset headset must be paired via bluetooth utility. The correct Mindset bluetooth serial port must be configured in Thinkgear connector (usually in OS X: /dev/tty.Mindset-DevB). USAGE To improve control capabilties : do not move and the frontal electrode should be one finger width above left eyebrow. OS X: switch on and wear Mindset start Thinkgear connector (TGC) The headset should connect to TGC. If not : check headset or TGC parameters : usually /dev/tty.MindSet-DevB as port. Double click Startup Icon Double Click jBMM Icon, assuming rebol is in the PATH. Otherwise the terminal command is yourreboldirectory/rebol jbmm.r Windows: switch on and wear Mindset start Thinkgear connector (TGC) connect TGC to headset Doubleclick on jbmm.r Initializing: When the pure data patch is correctly loaded, click on highGam checkbox : to be validated. On jBMM UI click on pDATA to initiate the link with the Pure Data patch. Run: Start and Stop are obvious on jBMM User Interface. The user interface has a built in display line, that guide through the calibration process. VirtualLED is shown on top right and switch Green or Red according to the last 5 seconds average of High gamma wave value (high level mental task). The switching value can be changed : VirtualLED lvl. This value can be saved as preferences, using save button. DISPLAYED MESSAGES "Connected. Improve signal to calibrate" : One of 4 the electrodes is not correctly contacting skin -> move the headset / remove hairs on hears ... "Calibrated" : all is fine, EEG data are processed. "Send Data ON" : sending data to Pure Data patch is switched ON "Send Data OFF" : sending data to Pure Data patch is switched OFF "WRONG SIGNALS" : EEG datas are not correct, is the headset correctly wear ? "TGC connexion error" : ThinkGear Connector provides buggy values, quit and restart Thinkgear Connector.
About
Basic Mind Music Player : alpha release. Work with Mindsets, not tested with Neurosky Mindwave.
Resources
Stars
Watchers
Forks
Releases
No releases published
Packages 0
No packages published