You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I have calibrated several times the Mynteye Camera using the Kalibr package as recommended. Upon completion of the calibration I obtain a delay of 5ms between the camera measurements and the imu measurements. Is this not somewhat to large to be used with visual inertial odometry estimation?
What time delay should I expect with the MyntEye Camera? I have build my own Stereo Camera with IMU and external Hardware trigger and I obtained delays below 1ms....
Could you please share your experience?
Kind regards,
Nicolas
The text was updated successfully, but these errors were encountered:
Hi,
I have calibrated several times the Mynteye Camera using the Kalibr package as recommended. Upon completion of the calibration I obtain a delay of 5ms between the camera measurements and the imu measurements. Is this not somewhat to large to be used with visual inertial odometry estimation?
What time delay should I expect with the MyntEye Camera? I have build my own Stereo Camera with IMU and external Hardware trigger and I obtained delays below 1ms....
Could you please share your experience?
Kind regards,
Nicolas
The text was updated successfully, but these errors were encountered: