title: Data Fitting
title: T2*
subtitle: Monoexponential T2 Mapping
date: 2024-07-25
authors:
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,90 @@
---
title: Noise
subtitle: Monoexponential T2 Mapping
date: 2024-07-25
authors:
- name: Samuelle Stonge
affiliations:
- NeuroPoly Lab, Polytechnique Montreal, Quebec, Canada
numbering:
heading_2: false
figure:
template: Fig. %s
---
In MRI, noise in the data can make it harder to accurately fit the T2 decay curve, which is problematic given the necessity for highly precise T2 values in clinical contexts. This issue is particularly pronounced when using pixel-wise T2 mapping, as the signal-to-noise (SNR) is much lower compared to region-of-interest (ROI) T2 mapping approaches (Sandino et al., 2015). Figure 4 shows how varying the level of noise in the acquired data can influence the fitting of the T2 relaxation curve and the resulting T2 constant. As observed in this figure, a low SNR can have a considerable impact on the T2 fitting process.


:::{figure} #fig3p3cell
:label: t2Plot3
Impact of noise on T2 relaxometry fitting. The figure shows a single voxel fit with a true T2 relaxation time of 109 ms. As the noise level increases, the accuracy of the T2 fitting decreases, leading to deviations in the estimated T2 relaxation time from the true value. This demonstrates how higher noise levels can adversely affect the reliability of T2 measurements and may result in inaccurate representations of tissue relaxation properties.
:::


The number of echoes used in T2 relaxometry is influenced by several factors, including the need for adequate spacing between echoes, the potential risk of heating the sample, and the challenges associated with processing data from samples with low signal-to-noise ratios. Therefore, selecting an optimal number of echoes is crucial for achieving accurate and reliable results while addressing these constraints (Shrager et al., 1998). The Cramer-Rao lower-bound (CRLB) method is a statistical tool that can be used in the context of T2 relaxometry to estimate the smallest possible variance, known as the lower bound, of an unbiased estimator given the noise present in the data (Cavassila et al., 2001). Using the lower bounds, the optimal number of echoes needed to accurately fit the T2 decay curve can be determined, ensuring more robust T2 mapping (Jones et al., 1996). In their work, Shrager et al. (1998) introduced another method for optimizing the selection of echo time points to improve the accuracy of T2 value estimates based on a predetermined range of expected T2 values. Their approach demonstrated superior accuracy compared to conventional methods that use uniformly-spaced echo times, suggesting that these methods are not optimal for T2 curve fitting accuracy.


```{admonition} Click here to view the qMRLab (MATLAB/Octave) code that generated Figure 1.
:class: tip, dropdown
```matlab
%% Requirements
% qMRLab must be installed: git clone https://www.github.com/qMRLab/qMRLab.git
% The mooc chapter branch must be checked out: git checkout mooc-03-T2
% qMRLab must be added to the path inside the MATLAB session: startup
%% T2 and T2* decay curves
close all
clear all
clc
% Define model
Model = mono_t2;
params.TE = linspace(0, 300, 100); % Echo times (in ms)
% Define signal parameters for different tissues
x = struct;
x.M0 = 1000;
x.T2 = 109; % (in ms)
% Define the signal-to-noise ratio
Opt1.SNR = 10;
Opt2.SNR = 50;
Opt3.SNR = 90;
Opt4.SNR = 130;
% Run the simulation for T2 and T2* decay curves
[FitResult_SNR10, data_SNR10] = Model.Sim_Single_Voxel_Curve(x, Opt1);
[FitResult_SNR50, data_SNR50] = Model.Sim_Single_Voxel_Curve(x, Opt2);
[FitResult_SNR90, data_SNR90] = Model.Sim_Single_Voxel_Curve(x, Opt3);
[FitResult_SNR130, data_SNR130] = Model.Sim_Single_Voxel_Curve(x, Opt4);
% T2 constants
T2_SNR10 = FitResult_SNR10.T2;
T2_SNR50 = FitResult_SNR50.T2;
T2_SNR90 = FitResult_SNR90.T2;
T2_SNR130 = FitResult_SNR130.T2;
% T2 decay curves
signal_SNR10 = FitResult_SNR10.M0/1000 * exp(-params.TE / FitResult_SNR10.T2);
signal_SNR50 = FitResult_SNR50.M0/1000 * exp(-params.TE / FitResult_SNR50.T2);
signal_SNR90 = FitResult_SNR90.M0/1000 * exp(-params.TE / FitResult_SNR90.T2);
signal_SNR130 = FitResult_SNR130.M0/1000 * exp(-params.TE / FitResult_SNR130.T2);
% Noisy data points
EchoTimes = [12.8000; 25.6000; 38.4000; 51.2000; 64.0000; 76.8000; 89.6000; 102.4000; 115.2000; 128.0000; 140.8000; 153.6000; 166.4000; 179.2000; 192.0000; 204.8000; 217.6000; 230.4000; 243.2000; 256.0000; 268.8000; 281.6000; 294.4000; 307.2000; 320.0000; 332.8000; 345.6000; 358.4000; 371.2000; 384.0000];
SEdata_SNR10 = data_SNR10.SEdata/1000;
SEdata_SNR50 = data_SNR50.SEdata/1000;
SEdata_SNR90 = data_SNR90.SEdata/1000;
SEdata_SNR130 = data_SNR130.SEdata/1000;
%% Export
disp(EchoTimes)
disp(params.TE)
save("t2_noise_simulation.mat", "params", "signal_SNR10", "signal_SNR50", "signal_SNR90", "signal_SNR130", "T2_SNR10", "T2_SNR50", "T2_SNR90", "T2_SNR130", "SEdata_SNR10", "SEdata_SNR50", "SEdata_SNR90", "SEdata_SNR130", "EchoTimes")
```

```
Original file line number Diff line number Diff line change
@@ -0,0 +1,17 @@
---
title: Benefits and Pitfalls
subtitle: Monoexponential T2 Mapping
date: 2024-07-25
authors:
- name: Samuelle Stonge
affiliations:
- NeuroPoly Lab, Polytechnique Montreal, Quebec, Canada
numbering:
heading_2: false
figure:
template: Fig. %s
---

The main benefit of mono-exponential T2 mapping is its simplicity and straightforward implementation, making it a convenient and efficient method for T2 fitting. Additionally, as mentioned previously, the use of multi-echo spin echo (MESE) sequences significantly reduces the acquisition time, further enhancing its practicality (Fatemi et al., 2020, (Milford et al., 2015).

Despite these advantages, mono-exponential methods have certain drawbacks. First, by assuming a single T2 relaxation constant per voxel, the mono-exponential method tends to over-simplify the tissue microstructure, potentially leading to inaccurate T2 estimations. This limitation can be particularly problematic when studying tissues that have a complex microstructure, where a single voxel may contain components with different T2 relaxation times. Furthermore, it has been shown that MESE sequences are sensitive to imperfections in the radiofrequency pulses. For instance, factors such as B1 inhomogeneities and reduced flip angles have been shown to overestimate T2 times when using mono-exponential methods. (Fatemi et al., 2020).
2 changes: 1 addition & 1 deletion binder/data_requirement.json
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,7 @@
"dst": "../data",
"projectName": "qmrlab-t1-book"
},
"03-T2":{ "src": "https://github.com/qMRLab/mooc-data/releases/download/v0.1/03-T2.zip",
"03-T2":{ "src": "https://github.com/qMRLab/mooc-data/releases/download/v0.1.2/03-T2.zip",
"dst": "../data",
"projectName": "03-T2"
}
Expand Down
Loading

0 comments on commit 641ee5b

Please sign in to comment.