docstring edits
Browse files Browse the repository at this point in the history
  • Loading branch information
cwhanse committed May 16, 2024
1 parent d0f3ebc commit 097ec36
Show file tree
Hide file tree
Showing 2 changed files with 36 additions and 35 deletions.
14 changes: 7 additions & 7 deletions docs/examples/snow-detection/snow-mode.py
Original file line number Diff line number Diff line change
Expand Up @@ -11,6 +11,12 @@
from snow-free irradiance measurements are ascribed to the effects of snow. The
effect of snow is classified into one of five categories:
* Mode -1: Indicates periods where it is unknown whether snow is impacting
system performance. This includes periods where voltage modeled with
measured irradiance assuming perfect transmission is below the inverter's
turn-on voltage, or when the same quantity is greater than the upper
bound on the inverter's MPPT range. Mode -1 also includes periods when
measured voltage exceeds the upper bound on the inverter's MPPT range.
* Mode 0: Indicates periods with enough opaque snow that the system is not
producing power. Specifically, Mode 0 is when the measured voltage is
below the inverter's turn-on voltage but the voltage modeled using
Expand All @@ -24,12 +30,6 @@
* Mode 3: Indicates periods when the operating voltage is consistent with
snow-free conditionss but current is reduced.
* Mode 4: Voltage and current are consistent with snow-free conditions.
* Mode -1: Indicates periods where it is unknown whether snow is impacting
system performance. This includes periods where voltage modeled with
measured irradiance assuming perfect transmission is below the inverter's
turn-on voltage, or when the same quantity is greater than the upper
bound on the inverter's MPPT range. Mode -1 also includes periods when
measured voltage exceeds the upper bound on the inverter's MPPT range.
Mode is None when both measured and voltage modeled from measured
irradiance are below the inverter turn-on voltage.
Expand Down Expand Up @@ -171,7 +171,7 @@
# point (MPP), and correct or mask. Conditions outside of the MPP cannot
# be accurately modeled without external information on the system's
# operating point. To allow us to make a valid comparison between system
# measurements and modeled power at MMP, we set measurements collected below
# measurements and modeled power at MPP, we set measurements collected below
# the MPPT minimum voltage to zero, which emulates the condition where the
# inverter turns off when it cannot meet the turn-on voltage.

Expand Down
57 changes: 29 additions & 28 deletions pvanalytics/features/snow.py
Original file line number Diff line number Diff line change
Expand Up @@ -8,12 +8,12 @@ def get_horizon_mask(horizon, azimuth, elevation):
Parameters
----------
horizon : pd.Series
horizon : array-like
Series with int index of 0 - 359 (represents azimuth) and float values
(represents elevation [deg] of horizon profile).
azimuth : numeric
azimuth : array-like
Solar azimuth angle. [deg]
elevation : numeric
elevation : array-like
Solar elevation angle. [deg]
Returns
Expand All @@ -35,9 +35,9 @@ def get_irradiance_sapm(temp_cell, i_mp, imp0, c0, c1, alpha_imp,
Parameters
----------
temp_cell : array
temp_cell : array-like
Temperature of cells inside module. [degrees C]
i_mp : array
i_mp : array-like
Maximum power current at the resolution of a single module. [A]
imp0 : float
Short-circuit current at reference condition. [A]
Expand All @@ -51,7 +51,7 @@ def get_irradiance_sapm(temp_cell, i_mp, imp0, c0, c1, alpha_imp,
Returns
-------
effective_irradiance : array
effective_irradiance : array-like
Effective irradiance. [W/m2]
References
Expand All @@ -78,14 +78,14 @@ def get_irradiance_imp(i_mp, imp0, irrad_ref=1000):
Parameters
----------
i_mp : array
i_mp : array-like
Maximum power current at the resolution of a single module. [A]
imp0 : float
Short-circuit current at reference condition. [A]
Returns
-------
effective_irradiance : array
effective_irradiance : array-like
Effective irradiance. [W/m2]
References
Expand All @@ -111,17 +111,17 @@ def get_transmission(measured_e_e, modeled_e_e, i_mp):
Parameters
----------
measured_e_e : array
measured_e_e : array-like
Plane-of-array irradiance absent the effect of snow. [W/m2]
modeled_e_e : array
modeled_e_e : array-like
Effective irradiance modeled from measured current at maximum power.
[W/m2]
i_mp : array
i_mp : array-like
Maximum power DC current at the resolution of a single module. [A]
Returns
-------
T : array
T : array-like
Effective transmission. [unitless] Returns NaN where measured DC
current is NaN and where measured irradiance is zero. Returns zero
where measured current is zero. Returns 1 where the ratio between
Expand Down Expand Up @@ -157,6 +157,19 @@ def categorize(transmission, measured_voltage,
Modes are defined in [1]_:
* Mode -1: Indicates periods where it is unknown if and how snow impacts
power output. Mode -1 includes periods when:
1. voltage modeled with measured irradiance is below the inverter's
turn-on voltage OR
2. voltage modeled with measured irradiance exceeds the upper bound
of the inverter's MPPT algorithm OR
3. measured voltage exceeds the upper bound of the inverter's MPPT
algorithm.
Mode -1 is added in this function to cover a case that was not addressed
in [1]_.
* Mode 0: Indicates periods with enough opaque snow that the system is not
producing power. Specifically, Mode 0 is when the measured voltage is
below the inverter's turn-on voltage but the voltage modeled using
Expand All @@ -170,25 +183,9 @@ def categorize(transmission, measured_voltage,
* Mode 3: Indicates periods when the operating voltage is consistent with
snow-free conditionss but current is reduced.
* Mode 4: Voltage and current are consistent with snow-free conditions.
* Mode is None when both measured and voltage modeled from measured
irradiance are below the inverter turn-on voltage.
An additional mode was added to cover a case that was not addressed in
[1]_:
* Mode -1: Indicates periods where it is unknown if and how snow impacts
power output. Mode -1 includes periods when
(a) voltage modeled with measured irradiance is below the inverter's
turn-on voltage OR
(b) voltage modeled with measured irradiance exceeds the upper bound of
the inverter's MPPT algorithm OR
(c) measured voltage exceeds the upper bound of the inverter's MPPT
algorithm
Parameters
----------
vmp_ratio : array-like
Ratio between measured voltage and voltage modeled using
calculated values of transmission. [dimensionless]
transmission : array-like
Fraction of plane-of-array irradiance that can reach the array's cells
through the snow cover. [dimensionless]
Expand Down Expand Up @@ -217,7 +214,11 @@ def categorize(transmission, measured_voltage,
Returns
-------
mode : int or None
``mode`` is ``None`` when any of the inputs used to determine ``mode``
is ``nan``.
References
----------
.. [1] E. C. Cooper, J. L. Braid and L. M. Burnham, "Identifying the
Electrical Signature of Snow in Photovoltaic Inverter Data," 2023 IEEE
50th Photovoltaic Specialists Conference (PVSC), San Juan, PR, USA,
Expand Down