Skip to content
ChrstphrR edited this page Jul 3, 2023 · 1 revision

Note: All commands are CaseSensitive.

Commands to use with kw1281test:

  • ActuatorTest

  • AdaptationRead CHANNEL [LOGIN]

    • CHANNEL = Channel number (0-99)
    • LOGIN = Optional login (0-65535)
  • AdaptationSave CHANNEL VALUE [LOGIN]

    • CHANNEL = Channel number (0-99)
    • VALUE = Channel value (0-65535)
    • LOGIN = Optional login (0-65535)
  • AdaptationTest CHANNEL VALUE [LOGIN]

    • CHANNEL = Channel number (0-99)
    • VALUE = Channel value (0-65535)
    • LOGIN = Optional login (0-65535)
  • BasicSetting GROUP

    • GROUP = Group number (0-255)
    • (Group 0: Raw controller data)
  • ClarionVWPremium4SafeCode

  • ClearFaultCodes

  • DelcoVWPremium5SafeCode

  • DumpEdc15Eeprom [FILENAME]

    • FILENAME = Optional filename
  • DumpEeprom START LENGTH [FILENAME]

    • START = Start address in decimal (e.g. 0) or hex (e.g. $0)
    • LENGTH = Number of bytes in decimal (e.g. 2048) or hex (e.g. $800)
    • FILENAME = Optional filename
  • DumpMarelliMem START LENGTH [FILENAME]

    • START = Start address in decimal (e.g. 3072) or hex (e.g. $C00)
    • LENGTH = Number of bytes in decimal (e.g. 1024) or hex (e.g. $400)
    • FILENAME = Optional filename
  • DumpMem START LENGTH [FILENAME]

    • START = Start address in decimal (e.g. 8192) or hex (e.g. $2000)
    • LENGTH = Number of bytes in decimal (e.g. 65536) or hex (e.g. $10000)
    • FILENAME = Optional filename
  • DumpRBxMem START LENGTH [FILENAME]

    • START = Start address in decimal (e.g. 66560) or hex (e.g. $10400)
    • LENGTH = Number of bytes in decimal (e.g. 1024) or hex (e.g. $400)
    • FILENAME = Optional filename
  • FindLogins LOGIN

    • LOGIN = Known good login (0-65535)
  • GetSKC

  • GroupRead GROUP

    • GROUP = Group number (0-255)
    • (Group 0: Raw controller data)
  • LoadEeprom START FILENAME

    • START = Start address in decimal (e.g. 0) or hex (e.g. $0)
    • FILENAME = Name of file containing binary data to load into EEPROM
  • MapEeprom

  • ReadFaultCodes

  • ReadIdent

  • ReadEeprom ADDRESS

    • ADDRESS = Address in decimal (e.g. 4361) or hex (e.g. $1109)
  • ReadRAM ADDRESS

    • ADDRESS = Address in decimal (e.g. 4361) or hex (e.g. $1109)
  • ReadROM ADDRESS

    • ADDRESS = Address in decimal (e.g. 4361) or hex (e.g. $1109)
  • ReadSoftwareVersion

  • Reset

  • SetSoftwareCoding CODING WORKSHOP

    • CODING = Software coding in decimal (e.g. 4361) or hex (e.g. $1109)
    • WORKSHOP = Workshop code in decimal (e.g. 4361) or hex (e.g. $1109)
  • ToggleRB4Mode

  • WriteEeprom ADDRESS VALUE

    • ADDRESS = Address in decimal (e.g. 4361) or hex (e.g. $1109)
    • VALUE = Value in decimal (e.g. 138) or hex (e.g. $8A)