Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathB1035.051.json
233 lines (233 loc) · 11.6 KB
/
B1035.051.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
{
"UniqueID": "55badc64-f473-4a64-9bd9-f94e659430bb",
"ID": "B1035.051",
"Description": "Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost.",
"BasicUnit": "Each",
"Name": "Pre-Northridge WUF-B beam-column joint, beam both sides of column, beam depth <= W27",
"Author": "Greg Deierlein",
"Correlation": 0,
"Directional": true,
"EDPType": {
"Dimension": "NumLevels",
"TypeName": "Story Drift Ratio",
"DefaultUnits": "Radian",
"UserDefined": false
},
"Ratings": {
"DataQuality": "Average",
"DataRelevance": "Average",
"Documentation": "Superior",
"Rationality": "Superior"
},
"Official": true,
"DateCreated": "2012-10-12T16:47:42.5525683-07:00",
"Approved": true,
"Incomplete": false,
"Notes": "None",
"UseEDPValueOfFloorAbove": false,
"DamageStates": {
"DSGroupType": "Sequential",
"DamageState": [
{
"Name": null,
"Description": "Fracture of lower beam flange weld and failure of web bolts (shear tab connection), with fractures confined to the weld region. ",
"DamageImageName": "B1035.041-DS1-1.JPG",
"DamageStates": {
"DSGroupType": "MutuallyExclusive",
"DamageState": [
{
"Name": null,
"Description": "Fracture of lower beam flange weld and failure of web bolts (shear tab connection), with fractures confined to the weld region. ",
"DamageImageName": "B1035.041-DS1-1.JPG",
"ConsequenceGroup": {
"RepairMeasures": "Repair will typically require gouging out and re-welding of the beam flange weld, repair of shear tab, and replacing shear bolts.",
"TagState": "Red",
"UseCasualty": false,
"LongLeadFlag": false,
"AffectedFloorArea": null,
"AffectedDeathRate": 0,
"AffectedInjuryRate": 0,
"AffectedDeathRateBeta": 0,
"AffectedInjuryRateBeta": 0,
"RedTagMedian": 0.5,
"RedTagBeta": 0.5,
"CostConsequence": {
"LowerQuantity": 10,
"MaxAmount": 21096,
"UpperQuantity": 30,
"MinAmount": 14064,
"Uncertainty": 0.3584,
"CurveType": "Normal"
},
"TimeConsequence": {
"LowerQuantity": 10,
"MaxAmount": 57.9118,
"UpperQuantity": 30,
"MinAmount": 38.6082,
"Uncertainty": 0.3585,
"CurveType": "Normal"
}
},
"Percent": 0.75
},
{
"Name": null,
"Description": "Similar to DS1, except that fracture propagates into column flanges.",
"DamageImageName": "B1035.041-DS2-1.JPG",
"ConsequenceGroup": {
"RepairMeasures": "DESCRIPTION IS NOT COMPLETE: In addition to column measures for DS1, repairs to column will be necessary that will involve replacing a portion of the \u2026.",
"TagState": "Red",
"UseCasualty": false,
"LongLeadFlag": false,
"AffectedFloorArea": null,
"AffectedDeathRate": 0,
"AffectedInjuryRate": 0,
"AffectedDeathRateBeta": 0,
"AffectedInjuryRateBeta": 0,
"RedTagMedian": 0.5,
"RedTagBeta": 0.5,
"CostConsequence": {
"LowerQuantity": 10,
"MaxAmount": 22896,
"UpperQuantity": 30,
"MinAmount": 15264,
"Uncertainty": 0.3578,
"CurveType": "Normal"
},
"TimeConsequence": {
"LowerQuantity": 10,
"MaxAmount": 62.8553,
"UpperQuantity": 30,
"MinAmount": 41.9047,
"Uncertainty": 0.3578,
"CurveType": "Normal"
}
},
"Percent": 0.25
}
]
},
"Median": 0.017,
"Beta": 0.4
},
{
"Name": null,
"Description": "Fracture of upper beam flange weld, without DS1 type damage. Fracture is confined to beam flange region. ",
"DamageImageName": null,
"DamageStates": {
"DSGroupType": "MutuallyExclusive",
"DamageState": [
{
"Name": null,
"Description": "Fracture of upper beam flange weld, without DS1 type damage. Fracture is confined to beam flange region. ",
"DamageImageName": null,
"ConsequenceGroup": {
"RepairMeasures": "Repairs will be similar to those required for DS1, except that access to weld will likely require removal of a portion of the floor slab above the weld.",
"TagState": "Red",
"UseCasualty": false,
"LongLeadFlag": false,
"AffectedFloorArea": null,
"AffectedDeathRate": 0,
"AffectedInjuryRate": 0,
"AffectedDeathRateBeta": 0,
"AffectedInjuryRateBeta": 0,
"RedTagMedian": 0.5,
"RedTagBeta": 0.5,
"CostConsequence": {
"LowerQuantity": 10,
"MaxAmount": 29496,
"UpperQuantity": 30,
"MinAmount": 19664,
"Uncertainty": 0.3041,
"CurveType": "Normal"
},
"TimeConsequence": {
"LowerQuantity": 10,
"MaxAmount": 80.9649,
"UpperQuantity": 30,
"MinAmount": 53.9751,
"Uncertainty": 0.3041,
"CurveType": "Normal"
}
},
"Percent": 0.75
},
{
"Name": null,
"Description": "Similar to DS3, except that fracture propagates into column flanges.",
"DamageImageName": null,
"ConsequenceGroup": {
"RepairMeasures": "In addition to column measures for DS3, repairs to column will be necessary that will involve replacing a portion of the column flange.",
"TagState": "Red",
"UseCasualty": false,
"LongLeadFlag": false,
"AffectedFloorArea": null,
"AffectedDeathRate": 0,
"AffectedInjuryRate": 0,
"AffectedDeathRateBeta": 0,
"AffectedInjuryRateBeta": 0,
"RedTagMedian": 0.5,
"RedTagBeta": 0.5,
"CostConsequence": {
"LowerQuantity": 10,
"MaxAmount": 28944,
"UpperQuantity": 30,
"MinAmount": 19296,
"Uncertainty": 0.318,
"CurveType": "Normal"
},
"TimeConsequence": {
"LowerQuantity": 10,
"MaxAmount": 79.4524,
"UpperQuantity": 30,
"MinAmount": 52.9676,
"Uncertainty": 0.318,
"CurveType": "Normal"
}
},
"Percent": 0.25
}
]
},
"Median": 0.025,
"Beta": 0.4
},
{
"Name": null,
"Description": "Fracture initiating at weld access hole and propagating through beam flange, possibly accompanied by local buckling deformations of web and flange. ",
"DamageImageName": null,
"ConsequenceGroup": {
"RepairMeasures": "Repair is similar to that for DS1 except that a portion of the beam web and flange may need to be heat straightened or replaced.",
"TagState": "Red",
"UseCasualty": false,
"LongLeadFlag": false,
"AffectedFloorArea": null,
"AffectedDeathRate": 0,
"AffectedInjuryRate": 0,
"AffectedDeathRateBeta": 0,
"AffectedInjuryRateBeta": 0,
"RedTagMedian": 0.5,
"RedTagBeta": 0.5,
"CostConsequence": {
"LowerQuantity": 10,
"MaxAmount": 22656,
"UpperQuantity": 30,
"MinAmount": 15104,
"Uncertainty": 0.3264,
"CurveType": "Normal"
},
"TimeConsequence": {
"LowerQuantity": 10,
"MaxAmount": 62.2,
"UpperQuantity": 30,
"MinAmount": 41.5,
"Uncertainty": 0.326,
"CurveType": "Normal"
}
},
"Median": 0.03,
"Beta": 0.4
}
]
}
}