The goal of this project is to implement a network slicing approach to enable dynamic activation and deactivation of network slicing via CLI/GUI commands. To achieve this goal, five scenarios are proposed, each with the same network topology. The goal is to observe how the network responds to small or large changes in the different elements of the network.
The network topology is organized as follow:
- A SDN controller,
c1
. - Four OpenFlow switches
s1-s4
with a fixed bandwidth of 100 Mbits/sec. - Four slices, each containing two hosts for a total of eight,
h1-h8
. Two of these slices are common and require 20% of the available bandwidth, while the others are considered critical. This means that when these slices are activated and their hosts are connected, they require 80% of the available bandwidth. The slices are coupled based on the number. Therefore, slices 1 will communicate with switches s1, s2, and s4, while slices 2 will communicate with switches s1, s3, and s4. Of course, this is the normal operation of the network. In case of variations (e.g., a switch failure as happens in scenario 5), they can lead to changes in the packet flow.
In this scenario, there are four hosts and four switches. The two common slices are activated, which means that they are able to use the maximum bandwidth available of 100 Mbits/sec.
By running pingall
command, it will show which hosts can be reached by a single host and this output will reflect the network structure described above. If you would like more information about how packets sent by the hosts are forwarded through the network, you can execute dpctl dump-flows
to view the flow table.
In addition, to verify the accuracy of the network bandwidth, you can check the bandwidth between two hosts via iperf <host1> <host2>
command.
Note: the real bandwidth may vary from the theoretical bandwidth.
In this scenario, there are six hosts and four switches. The two common slices and the critical slice 1 have been activated. However, only common slice 1 is able to use the maximum bandwidth of 100 Mbits/sec. This is because the bandwidth available to common slice 1 has been reduced due to the activation of critical slice 1. Therefore, common slice 1 can only access a bandwidth of 20 Mbits/sec (20%), while critical slice 1 has access to 80 Mbits/sec (80%).
By running pingall
command, it will show which hosts can be reached by a single host and this output will reflect the network structure described above. If you would like more information about how packets sent by the hosts are forwarded through the network, you can execute dpctl dump-flows
to view the flow table.
In addition, to verify the accuracy of the network bandwidth, you can check the bandwidth between two hosts via iperf <host1> <host2>
command.
Note: the real bandwidth may vary from the theoretical bandwidth.
This scenario is similar to the previous one, except that in this case, the bandwidth reduction has affected common slice 2 instead of common slice 1. This reduction is due to the activation of critical slice 2.
By running pingall
command, it will show which hosts can be reached by a single host and this output will reflect the network structure described above. If you would like more information about how packets sent by the hosts are forwarded through the network, you can execute dpctl dump-flows
to view the flow table.
In addition, to verify the accuracy of the network bandwidth, you can check the bandwidth between two hosts via iperf <host1> <host2>
command.
Note: the real bandwidth may vary from the theoretical bandwidth.
This scenario combines the Upper and the Lower ones. In fact, this time the bandwidth reduction affects both common slices due to the activation of both critical slices.
By running pingall
command, it will show which hosts can be reached by a single host and this output will reflect the network structure described above. If you would like more information about how packets sent by the hosts are forwarded through the network, you can execute dpctl dump-flows
to view the flow table.
In addition, to verify the accuracy of the network bandwidth, you can check the bandwidth between two hosts via iperf <host1> <host2>
command.
Note: the real bandwidth may vary from the theoretical bandwidth.
In this scenario, switch 3 breaks, and as a result, all network traffic needs to be routed through switch 2. This will result in a reduction of available bandwidth for all four slices, with critical slices having a bandwidth of 40 Mbits/sec (40%) and common slices having a bandwidth of 10 Mbits/sec (10%).
By running pingall
command, it will show which hosts can be reached by a single host and this output will reflect the network structure described above. If you would like more information about how packets sent by the hosts are forwarded through the network, you can execute dpctl dump-flows
to view the flow table.
In addition, to verify the accuracy of the network bandwidth, you can check the bandwidth between two hosts via iperf <host1> <host2>
command.
Note: the real bandwidth may vary from the theoretical bandwidth.
Follow the instruction available at this link. Once installed, you will need to follow these additional steps:
-
Locate the newly installed VM labeled "Comnetsemu Ubuntu Stand alone". Click on the Settings button for this VM, and then navigate to the Network tab. Once there, select Adapter 1 and click on the Advanced button. From the dropdown menu, select Port Forwarding. Next, add the following two rules:
Name: SSH, Protocol: TCP, Host Port: 2222, Guest Port 22
.Name: SOCKET, Protocol: TCP, Host IP: 127.0.0.1, Host Port: 2223, Guest Port: 2223
.
The first one is used to allow the Web Application on the host machine to connect via ssh to the VM. The second one is used for the socket used for the communication between the Mininet network and the Web Application.
You should get something like this:
- Copy the OnDemandSDNSlices folder inside the VM or, alternatively, you can copy and paste this command to do it automatically:
git clone https://github.com/christiansassi/networking-2-project.git && cd networking-2-project && mv OnDemandSDNSlices .. && cd .. && sudo rm -r networking-2-project && cd OnDemandSDNSlices
. - Go to scenarios folder and type
chmod +x *.sh
.
Note: the VM must be ON during the entire utilization of the Web Application.
- Copy the WebApp folder inside the VM.
- Install the required python packages by running
pip install -r requirements.txt
inside the WebApp folder. - Put the path of the launcher.py script (which is in the VM) in the
LAUNCHER_PATH
variable of the master.py script.
Note: if you are logging as vagrant inside the VM, change the values of the
SSH_USERNAME
andSSH_PASSWORD
variables to "vagrant" in the master.py script.
It's possible to try and test the project via CLI. In order to do that, start the Mininet network by executing the following commands:
- Navigate to the network folder and execute
ryu-manager controller.py
. This command will start the controller. - In another terminal window, navigate to the network folder and execute
sudo python3 topology.py
and wait until you see themininet >
terminal. This command will start the Mininet network in CLI mode. - In another terminal window, navigate to the scenarios and run the scenario of your choice by executing the corresponding *.sh file. This script will setup the network to the desired scenario.
You are now free to try any command you wish. Simply type help
to see a list of all available commands. Once you are done, digit exit
in the mininet terminal.
Note: if you encounter any issues while running
topology.py
, try clearing everything by executingsudo mn -c
. Additionally, ensure that the controller is running before starting Mininet.
Alternatively, instead of using the CLI interface, you can test the Mininet network by connecting to the Web Application and using the provided GUI. In order to do that, start the Web Application by following these steps:
- Navigate to the WebApp folder and execute
python WebApp.py
orpython2 WebApp.py
orpython3 WebApp.py
depending on your python version and operating system. - Now, open your browser and navigate to http://127.0.0.1:5000.
Note: the port may vary depending on the processes running on your system.
The Web Application provides the ability to perform the following operations:
- Turn the Mininet network ON/OFF by clicking the switch button located in the top left corner of the page.
- Change the scenario. The Mininet network loads the default scenario when started. Clicking on the other buttons allows you to load one of the previously described scenarios.
Moreover, you can view the following informations:
- The color of the circle in the last column of the table indicates the currently active host or switch.
- Theoretical and real bandwidth. These informations can provide insights into how the network operates. It's important to note that the two bandwidth types aren't always equal.
- The diagram of the current scenario.