Skip to content

Commit

Permalink
fix the oidc instructions to update deprecated MS Entra steps (#4887)
Browse files Browse the repository at this point in the history
* fix the oidc instructions to remove deprecated entra steps

* update attribute link
  • Loading branch information
conceptualshark authored Jan 23, 2025
1 parent e7ae027 commit a93b34e
Show file tree
Hide file tree
Showing 4 changed files with 8 additions and 8 deletions.
4 changes: 2 additions & 2 deletions docs/self-managed/setup/guides/connect-to-an-oidc-provider.md
Original file line number Diff line number Diff line change
Expand Up @@ -232,10 +232,10 @@ The client should be configured to support `grant_type`:
To successfully authenticate with Entra ID, you should use the `v2.0` API. This means that
the `CAMUNDA_IDENTITY_ISSUER_BACKEND_URL` value should end with `/v2.0`.

It's also important to follow the [steps described here](https://learn.microsoft.com/en-us/entra/identity-platform/reference-app-manifest#configure-the-app-manifest) to configure the app manifest and set the [accesstokenAcceptedVersion](https://learn.microsoft.com/en-us/entra/identity-platform/reference-app-manifest#accesstokenacceptedversion-attribute) to `2` like so:
Follow the [Microsoft Entra instructions](https://learn.microsoft.com/en-us/entra/identity-platform/reference-microsoft-graph-app-manifest#configure-the-app-manifest-in-the-microsoft-entra-admin-center) to configure the app manifest, and set the [requestedAccessTokenVersion](https://learn.microsoft.com/en-us/entra/identity-platform/reference-microsoft-graph-app-manifest#api-attribute) under `Api:` to `2`:

```json
"accessTokenAcceptedVersion": 2,
"requestedAccessTokenVersion": 2,
```

</TabItem>
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -204,10 +204,10 @@ The client should be configured to support `grant_type`:
To successfully authenticate with Entra ID, you should use the `v2.0` API. This means that
the `CAMUNDA_IDENTITY_ISSUER_BACKEND_URL` value should end with `/v2.0`.

It's also important to follow the [steps described here](https://learn.microsoft.com/en-us/entra/identity-platform/reference-app-manifest#configure-the-app-manifest) to configure the app manifest and set the [accesstokenAcceptedVersion](https://learn.microsoft.com/en-us/entra/identity-platform/reference-app-manifest#accesstokenacceptedversion-attribute) to `2` like so:
Follow the [Microsoft Entra instructions](https://learn.microsoft.com/en-us/entra/identity-platform/reference-microsoft-graph-app-manifest#configure-the-app-manifest-in-the-microsoft-entra-admin-center) to configure the app manifest, and set the [requestedAccessTokenVersion](https://learn.microsoft.com/en-us/entra/identity-platform/reference-microsoft-graph-app-manifest#api-attribute) under `Api:` to `2`:

```json
"accessTokenAcceptedVersion": 2,
"requestedAccessTokenVersion": 2,
```

</TabItem>
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -225,10 +225,10 @@ The client should be configured to support `grant_type`:
To successfully authenticate with Entra ID, you should use the `v2.0` API. This means that
the `CAMUNDA_IDENTITY_ISSUER_BACKEND_URL` value should end with `/v2.0`.

It's also important to follow the [steps described here](https://learn.microsoft.com/en-us/entra/identity-platform/reference-app-manifest#configure-the-app-manifest) to configure the app manifest and set the [accesstokenAcceptedVersion](https://learn.microsoft.com/en-us/entra/identity-platform/reference-app-manifest#accesstokenacceptedversion-attribute) to `2` like so:
Follow the [Microsoft Entra instructions](https://learn.microsoft.com/en-us/entra/identity-platform/reference-microsoft-graph-app-manifest#configure-the-app-manifest-in-the-microsoft-entra-admin-center) to configure the app manifest, and set the [requestedAccessTokenVersion](https://learn.microsoft.com/en-us/entra/identity-platform/reference-microsoft-graph-app-manifest#api-attribute) under `Api:` to `2`:

```json
"accessTokenAcceptedVersion": 2,
"requestedAccessTokenVersion": 2,
```

</TabItem>
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -232,10 +232,10 @@ The client should be configured to support `grant_type`:
To successfully authenticate with Entra ID, you should use the `v2.0` API. This means that
the `CAMUNDA_IDENTITY_ISSUER_BACKEND_URL` value should end with `/v2.0`.

It's also important to follow the [steps described here](https://learn.microsoft.com/en-us/entra/identity-platform/reference-app-manifest#configure-the-app-manifest) to configure the app manifest and set the [accesstokenAcceptedVersion](https://learn.microsoft.com/en-us/entra/identity-platform/reference-app-manifest#accesstokenacceptedversion-attribute) to `2` like so:
Follow the [Microsoft Entra instructions](https://learn.microsoft.com/en-us/entra/identity-platform/reference-microsoft-graph-app-manifest#configure-the-app-manifest-in-the-microsoft-entra-admin-center) to configure the app manifest, and set the [requestedAccessTokenVersion](https://learn.microsoft.com/en-us/entra/identity-platform/reference-microsoft-graph-app-manifest#api-attribute) under `Api:` to `2`:

```json
"accessTokenAcceptedVersion": 2,
"requestedAccessTokenVersion": 2,
```

</TabItem>
Expand Down

0 comments on commit a93b34e