Module for H300 VFD

Manufacturer: Forin.sk Model: H300-OD75S2G Module type (code): VFD_H300 Protocol: Modbus-RTU Author: Martin Stradiot

Address format: Modbus-RTU address: number 1 to 255

Datapoints:

Datapoint name Datapoint code Units Writable Description Value example
Speed SPEED % true Read/Write datapoint used to set frequency in percentage (single decimal precision) of set frequency (SET_FREQ). Possible values: <0.0,100.0>. 50.0
Motion setting SET_MOTION - true Write-only datapoint used to control motor motion. Possible values: "FWD" - forward, "REV" - reverse, "FWD_JOG" - forward jogging, "REV_JOG" - reverse jogging, "STOP" - break-free stop, "BREAK" - stop using breaks FWD
Motion state GET_MOTION - false Used to get motion state. Possible values: "FWD" - running forward, "REV" - running reverse, "STOP" - stop REV
Status STATE - false Used to determine error state of VFD. Possible values: "OK" - no error, "ERROR %N" - error code, where %N id number. ERROR 1
Actual frequency GET_FREQ Hz false Actual output frequency. Two decimal precision. 12.34
Frequency setpoint SET_FREQ Hz true Read/Write datapoint used to set output frequency (at 100% SPEED). Two decimal precision. Possible values: <0.00,500> 30.00
Acceleration time ACCEL_TIME s true Read/Write datapoint used to set accceleration time in seconds. Time to reach set SPEED from stop position. Integer numbers only. 10
Deceleration time DECEL_TIME s true Read/Write datapoint used to set decceleration time in seconds. Time for to reach zero SPEED using breaking. Integer numbers only. 20
Actual remaining running time GET_TIMER min false Remaining time until the motor starts slowing down until fully stopped. Timer starts immediately after SET_MOTION. ACCEL_TIME is included in this timer, DECEL_TIME is not. Single decimal precision (6s). 2.5
Timer setpoint SET_TIMER min true Read/Write datapoint used to set the timer. This is the max value for GET_TIMER. Value 0 menas no timer - endless operation until stopped manually. Unlike GET_TIMER, this value does not represent actual remaining time, but rather the setpoint and does not change itself automatically. Single decimal precision (6s). 2.5
Actual RPM RPM rpm false Used to get actual motor rpm (rounds per minute). This datapoint is calculated and represents value in ideal conditions with no load attached to the motor. 420

Wiring scheme: Wiring scheme