IMOS Toolbox v2.5.7 - 26 Apr 2016
Changes from 2.5.6:
-Add support for average and burst data from Signature .mat files. a36719a
-Revert modification on time stamping for RDI ADCPs and RBR CTDs processed Windows v6.13. Time stamp is left untouched at the start of the measurement. Global attribute instrument_average_interval, TIME variable attributes comment and seconds_to_middle_of_measurement have been added and documented accordingly for both velocity and wave dataset. Nortek ADCPs have been treated similarly (except Signature, not clear). 696cd32
-Add support for user magnetic declination applied on Nortek Signature ADCPs. a86e515
-Fix depthPP when 2 nearest below P sensors are at the same nominal_depth (stuck in while loop). Fix depthPP when using height above bottom instead of nominal depth convention, would look for 2 nearest above while should only do so for 2 nearest below. Cleaned a bit logic and comments. 3f6fe48
-Scatter plots from menu can also work when there is no depth but nominal depth information. Marker style updated to remove non easily visible ones. 4850cd1
-Fix imosTiltVelocitySetQC in case ADCP does not output WCUR. 616a383
-Increment toolbox version 2.5.7. Update binaries accordingly. bc84d02
Changes from 2.4:
imos-toolbox-2.5.7_changes_from_2.4.txt
See branch 2.5 for access to critical fix.