Notifications
You must be signed in to change notification settings - Fork 12
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge pull request #12 from zsarnoczay/master
azs - add missing file to E7
- Loading branch information
Showing
1 changed file
with
174 additions
and
0 deletions.
There are no files selected for viewing
174 changes: 174 additions & 0 deletions
174
E7HurricaneWindWater/input_data/auto_pop/BuildingClassRulesets.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,174 @@ | ||
# -*- coding: utf-8 -*- | ||
# | ||
# Copyright (c) 2018 Leland Stanford Junior University | ||
# Copyright (c) 2018 The Regents of the University of California | ||
# | ||
# This file is part of the SimCenter Backend Applications | ||
# | ||
# Redistribution and use in source and binary forms, with or without | ||
# modification, are permitted provided that the following conditions are met: | ||
# | ||
# 1. Redistributions of source code must retain the above copyright notice, | ||
# this list of conditions and the following disclaimer. | ||
# | ||
# 2. Redistributions in binary form must reproduce the above copyright notice, | ||
# this list of conditions and the following disclaimer in the documentation | ||
# and/or other materials provided with the distribution. | ||
# | ||
# 3. Neither the name of the copyright holder nor the names of its contributors | ||
# may be used to endorse or promote products derived from this software without | ||
# specific prior written permission. | ||
# | ||
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" | ||
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE | ||
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE | ||
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE | ||
# LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR | ||
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF | ||
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS | ||
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN | ||
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) | ||
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE | ||
# POSSIBILITY OF SUCH DAMAGE. | ||
# | ||
# You should have received a copy of the BSD 3-Clause License along with | ||
# this file. If not, see <http://www.opensource.org/licenses/>. | ||
# | ||
# Contributors: | ||
# Adam Zsarnóczay | ||
# Kuanshi Zhong | ||
# | ||
# Based on rulesets developed by: | ||
# Karen Angeles | ||
# Meredith Lockhead | ||
# Tracy Kijewski-Correa | ||
|
||
import random | ||
import numpy as np | ||
import datetime | ||
|
||
|
||
def building_class(BIM, hazard): | ||
""" | ||
Short description | ||
Long description | ||
Parameters | ||
---------- | ||
BIM: dictionary | ||
Information about the building characteristics. | ||
Returns | ||
------- | ||
bldg_class: str | ||
One of the standard building class labels from HAZUS | ||
""" | ||
|
||
# check hazard | ||
if hazard not in ['wind', 'inundation']: | ||
print(f'WARNING: The provided hazard is not recognized: {hazard}') | ||
|
||
if hazard == 'wind': | ||
|
||
if BIM['BuildingType'] == 'Wood': | ||
if ((BIM['OccupancyClass'] == 'RES1') or | ||
((BIM['RoofShape'] != 'flt') and (BIM['OccupancyClass'] == ''))): | ||
# BuildingType = 3001 | ||
# OccupancyClass = RES1 | ||
# Wood Single-Family Homes (WSF1 or WSF2) | ||
# OR roof type = flat (HAZUS can only map flat to WSF1) | ||
# OR default (by '') | ||
if BIM['RoofShape'] == 'flt': # checking if there is a misclassication | ||
BIM['RoofShape'] = 'gab' # ensure the WSF has gab (by default, note gab is more vulneable than hip) | ||
bldg_class = 'WSF' | ||
else: | ||
# BuildingType = 3001 | ||
# OccupancyClass = RES3, RES5, RES6, or COM8 | ||
# Wood Multi-Unit Hotel (WMUH1, WMUH2, or WMUH3) | ||
bldg_class = 'WMUH' | ||
elif BIM['BuildingType'] == 'Steel': | ||
if ((BIM['DesignLevel'] == 'E') and | ||
(BIM['OccupancyClass'] in ['RES3A', 'RES3B', 'RES3C', 'RES3D', | ||
'RES3E', 'RES3F'])): | ||
# BuildingType = 3002 | ||
# Steel Engineered Residential Building (SERBL, SERBM, SERBH) | ||
bldg_class = 'SERB' | ||
elif ((BIM['DesignLevel'] == 'E') and | ||
(BIM['OccupancyClass'] in ['COM1', 'COM2', 'COM3', 'COM4', 'COM5', | ||
'COM6', 'COM7', 'COM8', 'COM9','COM10'])): | ||
# BuildingType = 3002 | ||
# Steel Engineered Commercial Building (SECBL, SECBM, SECBH) | ||
bldg_class = 'SECB' | ||
elif ((BIM['DesignLevel'] == 'PE') and | ||
(BIM['OccupancyClass'] not in ['RES3A', 'RES3B', 'RES3C', 'RES3D', | ||
'RES3E', 'RES3F'])): | ||
# BuildingType = 3002 | ||
# Steel Pre-Engineered Metal Building (SPMBS, SPMBM, SPMBL) | ||
bldg_class = 'SPMB' | ||
else: | ||
bldg_class = 'SECB' | ||
elif BIM['BuildingType'] == 'Concrete': | ||
if ((BIM['DesignLevel'] == 'E') and | ||
(BIM['OccupancyClass'] in ['RES3A', 'RES3B', 'RES3C', 'RES3D', | ||
'RES3E', 'RES3F', 'RES5', 'RES6'])): | ||
# BuildingType = 3003 | ||
# Concrete Engineered Residential Building (CERBL, CERBM, CERBH) | ||
bldg_class = 'CERB' | ||
elif ((BIM['DesignLevel'] == 'E') and | ||
(BIM['OccupancyClass'] in ['COM1', 'COM2', 'COM3', 'COM4', 'COM5', | ||
'COM6', 'COM7', 'COM8', 'COM9','COM10'])): | ||
# BuildingType = 3003 | ||
# Concrete Engineered Commercial Building (CECBL, CECBM, CECBH) | ||
bldg_class = 'CECB' | ||
else: | ||
bldg_class = 'CECB' | ||
elif BIM['BuildingType'] == 'Masonry': | ||
if BIM['OccupancyClass'] == 'RES1': | ||
# BuildingType = 3004 | ||
# OccupancyClass = RES1 | ||
# Masonry Single-Family Homes (MSF1 or MSF2) | ||
bldg_class = 'MSF' | ||
elif ((BIM['OccupancyClass'] in ['RES3A', 'RES3B', 'RES3C', 'RES3D', | ||
'RES3E', 'RES3F']) and (BIM['DesignLevel'] == 'E')): | ||
# BuildingType = 3004 | ||
# Masonry Engineered Residential Building (MERBL, MERBM, MERBH) | ||
bldg_class = 'MERB' | ||
elif ((BIM['OccupancyClass'] in ['COM1', 'COM2', 'COM3', 'COM4', | ||
'COM5', 'COM6', 'COM7', 'COM8', 'COM9', | ||
'COM10']) and (BIM['DesignLevel'] == 'E')): | ||
# BuildingType = 3004 | ||
# Masonry Engineered Commercial Building (MECBL, MECBM, MECBH) | ||
bldg_class = 'MECB' | ||
elif BIM['OccupancyClass'] in ['IND1', 'IND2', 'IND3', 'IND4', 'IND5', 'IND6']: | ||
# BuildingType = 3004 | ||
# Masonry Low-Rise Masonry Warehouse/Factory (MLRI) | ||
bldg_class = 'MLRI' | ||
elif BIM['OccupancyClass'] in ['RES3A', 'RES3B', 'RES3C', 'RES3D', | ||
'RES3E', 'RES3F', 'RES5', 'RES6', 'COM8']: | ||
# BuildingType = 3004 | ||
# OccupancyClass = RES3X or COM8 | ||
# Masonry Multi-Unit Hotel/Motel (MMUH1, MMUH2, or MMUH3) | ||
bldg_class = 'MMUH' | ||
elif ((BIM['NumberOfStories'] == 1) and | ||
(BIM['OccupancyClass'] in ['COM1', 'COM2'])): | ||
# BuildingType = 3004 | ||
# Low-Rise Masonry Strip Mall (MLRM1 or MLRM2) | ||
bldg_class = 'MLRM' | ||
else: | ||
bldg_class = 'MECB' # for others not covered by the above | ||
#elif ((BIM['OccupancyClass'] in ['RES3A', 'RES3B', 'RES3C', 'RES3D', | ||
# 'RES3E', 'RES3F', 'RES5', 'RES6', | ||
# 'COM8']) and (BIM['DesignLevel'] in ['NE', 'ME'])): | ||
# # BuildingType = 3004 | ||
# # Masonry Multi-Unit Hotel/Motel Non-Engineered | ||
# # (MMUH1NE, MMUH2NE, or MMUH3NE) | ||
# return 'MMUHNE' | ||
elif BIM['BuildingType'] == 'Manufactured': | ||
bldg_class = 'MH' | ||
|
||
else: | ||
bldg_class = 'WMUH' | ||
# if nan building type is provided, return the dominant class | ||
|
||
return bldg_class |