Expand Up @@ -6,28 +6,56 @@ As previously mentioned, VIBSO's scope is the semantic description of vibrationa

### Questions addressing one single data set

* What kind of vibrational spectroscopy was performed (as detailed as possible: enhanced, resonant, stimulated, coherent, anti-Stokes...)?

* What kind of vibrational spectroscopy was performed (as detailed as possible: enhanced, resonant, stimulated,
coherent, anti-Stokes...)?
* In what context was it performed, e.g. as part of what study or investigation?

* What devices were used?

* What is the software version?
* Whats the instrument manufacturer?
* What is the instrument model?
* What is the instrument license number?
* Which user ID was used to operate the instrument?
* What were the protocol parameters & device configurations?

* What was the scan setting (e.g. range, CCD area x & y binninig)?
* What is the file extension of the measurement file?
* What is the unit of the measurement?
* What file output format is the measurement in?
* What is the types of acquisition for this measurement?
* What was the humidity and temperature of the collection environment?
* What are the light conditions around the sample? (closed or open space)
* Which laser wavelength was used for the measurement?
* What grating was used for the spectrum acquisition/measurement?
* What exposure time was used during the measurement?
* What detector was used for the measurement and what pixel resolution does it have?
* What lens was used for the measurement?
* What was the laser power percentage at the sample?
* How many accumulations were used?
* What was the spatial resolution of the system?
* Did you correct for the dark spectrum of the detector? (ie noise correction from detector)
* What kind of filters do you use for your measurement?
* Which slit position was used? Standard or high confocality?
* Has the autofocus been used?
* Have the data been acquired with an automatic cosmic ray removal?
* Who was involved in the assay? (identified by a PID like ORCID at best)

* What was the assayed sample, including its relevant attributes (e.g. substrate, production procedure, pre-treatment)?

* What is the dimensionality of the experiment (e.g. single spectra, line maps, surface maps, volume scans...)?

* What kind of post-processing (e.g. smoothing, baseline subtraction, band integration, peak recognition, image reconstruction) was done?
* What is the dimensionality of the experiment (e.g. single spectra/static scan, line maps, surface maps, volume scans...)?
* If the spectrum is a static scan, what is the center of the spectrum?
* What kind of preprocessing was done to the spectra?
* What kind of preprocessing was done on the sample?
* What kind of post-processing (e.g. smoothing, baseline subtraction, band integration, peak recognition, image
reconstruction) was done?
* Do you perform correction for spectral shifts?
* What were the data extraction steps that have been done on the spectra?
* For baseline correction, what are the applied baseline correction methods?
* If the cosmic ray removal was applied manually, what are the applied processing steps to do the cosmic ray
removal?
* What kind of preprocessing was done on the sample?
* Has the SNR been maintained for all measurements at expected levels?
* Were there any errors encountered during the measurement?

### Questions addressing the full database

* Find me all Raman spectra of wolfram wires on a silicium substrate covering the range 600-1800 cm^-1.

* Find me which is a safe range of incoming laser powers to perform Raman experiments at wavelength Z on sample XY.

* Find me a suitable solvent which is compatible with sample XY, i.e. which does not have any Raman peak or band between wavenumbers W1 and W2.

This list represents only a first draft and needs to be thoroughly discussed with the domain experts and the NFDI4Chem community.