Release 3.0.0-prerelease 1
Pre-release
Pre-release
·
51 commits
to develop-v3
since this release
Version 3.0
Date Range: 03/11/21 - 10/01/21
Category | Count |
---|---|
Controls | 0 |
Documentation | 2 |
General | 4 |
Measures | 8 |
Reports | 0 |
Systems | 5 |
Validation | 0 |
Other | 5 |
Total | 24 |
Change Type | Count |
---|---|
Breaking Change | 18 |
Non-breaking Change | 6 |
New Issues: 30 (#314, #318, #320, #321, #330, #333, #336, #337, #338, #343, #347, #356, #358, #361, #362, #370, #375, #391, #393, #397)
Closed Issues: 24
- Improved #230, Deprecate PrimaryHVACSystemType element
- Improved #233, Deprecate auc:WallID as direct child of auc:Side
- Improved #234, Deprecate auc:WindowID as direct child of auc:Side
- Improved #235, Deprecate auc:DoorID as direct child of auc:Side
- Improved #253, Deprecate OutputCapacity for HeatingSource and HeatingPlant types
- Improved #259, Deprecate auc:Delivery/auc:Capacity and auc:Delivery/auc:CapacityUnits
- Improved #264, Deprecate auc:FanSystem/auc:InstalledFlowRate
- Improved #268, Consider auc:MeasureName Refactor to minOccurs=1 maxOccurs=1
- Improved #271, Remove 'Add heat recovery' from EMCS Technology Category
- Improved #272, Redundant 'Separate SHW from heating' in Hot Water Systems and in SWH Tech Categories
- Improved #275, Remove
Energy cost reduction through rate adjustments - uncategorized
- Fixed #283, Deprecate: MORE in auc:eGRIDRegionCode enumeration
- Merged #296, DuctSystem/MaximumOAFlowRate Rename
- Improved #321, Restrict BuildingSync@version to actual version
- Improved #330, Remove redundant "Add or replace cooling tower" from Other HVAC
- Merged #333, Correct capitalization in
Convert to Cleaner Fuels
- Improved #336, Address issue using
/
with spaces - Improved #337, Redundant
Install or upgrade master venting
inChilledWaterHotWaterAndSteamDistributionSystems
andOtherHVAC
- Improved #338, Remove
FutureOtherECMs
measure category - Merged #343, Don't add future prerelease versions to official release schemas
- New Feature #347, Initial XSLT for translation between versions of BuildingSync
- New Feature #358, Primary, Secondary and Tertiary eGRID Subregion Codes
- New Feature #361, Update version translator to include all breaking changes
- New Feature #375, Create reverse translation from 3.0 to 2.4
Accepted Pull Requests: 24
- Merged #271, Remove 'Add heat recovery' from EMCS Technology Category
- Merged #272, Remove 'Separate SHW from heating’ from Hot Water Systems
- Merged #275, Remove Energy cost reduction through rate adjustments – uncategorized
- Merged #329, Remove redundant items
- Merged #331, Remove redundant "Add or replace cooling tower"
- Merged #334, Correct capitalization - change
Convert to Cleaner Fuels
toConvert to cleaner fuels
- Merged #335, Address issue using
/
with spaces - Merged #341, Refactor Measurename minOccurs maxOccurs
- Fixed #342, Deprecate MORE in eGRIDRegionCode
- Merged #345, Deprecate WallID as direct child under Side
- Merged #346, Docs/versioning v3
- Merged #348, Feat/translation
- Merged #350, Refactor/update simple types
- Merged #351, Deprecate InstalledFlowRate under FanSystem
- Merged #352, Deprecate PrimaryHVACSystemType
- Merged #353, Deprecate OutputCapacity for HeatingSource and HeatingPlant types
- Merged #354, Deprecate Capacity and CapacityUnits in Delivery
- Merged #360, Feat/v2 to v3 translation updates
- Merged #364, Deprecate DoorID and WindowID as direct Child under Side
- Merged #373, Docs/selection tool
- Merged #378, Feat/v3 to v2 translation
- Merged #389, Refactor/remove old versions
- Improved #394, Deprecate eGRIDRegionCode
- Improved #396, Deprecate MaximumOAFlowRate