Expand Up @@ -11,11 +11,12 @@ Overview

Schematic of the custom-built sEQE setup used in this work. White light from a tungsten-halogen light source is directed into a monochromator and split by wavelength. The monochromatic light is subsequently modulated by a chopper wheel and focused onto the device under testing (i.e. a solar cell or reference photodiode). When measuring OSCs, the devices are either loaded into a standard sample holder for room temperature measurements or connected inside a cryostat to perform temperature-dependent sEQE measurements. The resulting photocurrent is pre-amplified and converted to a voltage, before being analyzed further by a Lock-In amplifier

.. image:: ../_static/sEQE_setup_without_cryo_Labelled.png
.. image:: ../_static/Photo-EQE-Setup-Labelled.png
:width: 700
:alt: Photograph of the sEQE setup from above.
:alt: Photograph of the sEQE setup without cryostate from above.

Photo of the custom-built sensitive EQE setup used in this work. The individual components are numbered as (1) tungsten-halogen light source, (2) light source power supply, (3) monochromator, (4) filter wheels, (5) chopper wheel, (6) chopper wheel power supply, (7) focusing lenses, (8) sample holder stage, (9) custom-built sample holder, (10) BNC cables with crocodile clips, (11) preamplifier, (12) Lock-In amplifier, and (13) measurement computer.
Photo of the custom-built sensitive EQE setup used in this work. The individual components are numbered as (1a) tungsten-halogen light source, (1b) light source power supply, (2) monochromator, (3a) monochromator filter wheel, (3b) long-pass filter wheel, (4a) chopper wheel, (4b) chopper wheel power supply, (5) focusing lenses, (6) rail, (7) custom-built sample holder, (8) sample holder stage, (9) BNC cables with crocodile clips, (10) preamplifier, (11) Lock-In amplifier, (12) measurement computer and (13) black encasing.


Individual parts
----------------
Expand Down Expand Up @@ -47,6 +48,9 @@ The sEQE setup's sample holder is custom design by Grey and the 3D printed parts
Cryostate
---------



.. image:: ../_static/Photo-EQE-Setup-Labelled-With-Cryostat.png
:width: 700
:alt: Photograph of the sEQE setup with cryostate from above.

Photo of the custom-built sensitive EQE setup used in this work. The individual components are numbered as (1a) tungsten-halogen light source, (1b) light source power supply, (2) monochromator, (3a) monochromator filter wheel, (3b) long-pass filter wheel, (4a) chopper wheel, (4b) chopper wheel power supply, (5) focusing lenses, (6) rail, (7a) croystat chamber - sample holder, (7b) liquid nitrogen dewar, (7c) liquid nitrogen pump, (7d) cryostate control, (8) sample holder stage, (9) BNC cables, (10) preamplifier, (11) Lock-In amplifier, (12) measurement computer and (13) black encasing.