QoS recipe

This recipe describes how to set different QoS limits on an exposed virtio-bk device.

For this recipe, two physical machines are required. They are referred to as storage-target-platform and ipu-storage-container-platform. The containers running on those platforms are named storage-target and ipu-storage-container respectively.

To apply this scenario the following steps need to be applied:

  1. Perform all steps described in environment setup

  2. Run fio scenario to observe device throughput. In the fio command rw field can be replaced with randread or randwrite to exercise device only with reads or writes.

  3. Set required QoS limits. IPDK Storage Solution leverages SPDK SMA to get supported QoS capabilities and set required QoS limits.

To request supported virtio-blk capabilities, execute the following cmd from cmd-sender:

$ get_virtio_blk_qos_capabilities <ipu_storage_container_platform_ip> 8080

and expected output for KVM case is

{"max_device_caps": {"rw_iops": true, "rd_bandwidth": true, "wr_bandwidth": true, "rw_bandwidth": true}, "max_volume_caps": {"rw_iops": true, "rd_bandwidth": true, "wr_bandwidth": true, "rw_bandwidth": true}}

which says that for this device type per-volume and per-device QoS maximum limits are supported and we can set the following limits:

  • rw_iops - maximum Read/write kIOPS
  • rd_bandwidth - read bandwidth (MB/s)
  • wr_bandwidth - write bandwidth (MB/s)
  • rw_bandwidth - read/write bandwidth (MB/s)

to set QoS limit, run the command bellow replacing limit values in <> with required values from the supported capabilities. If a limit is not reported as supported in the capabilities, it must be set as 0

$ set_max_qos_limits <ipu_storage_container_platform_ip> 8080 $virtio_blk0 <volume_id> <rd_iops> <wr_iops> <rw_iops> <rd_bandwidth> <wr_bandwidth> <rw_bandwidth>

since virtio-blk devices support device level capabilities, so volume_id can be left empty.

$ set_max_qos_limits <ipu_storage_container_platform_ip> 8080 $virtio_blk0 "" <rd_iops> <wr_iops> <rw_iops> <rd_bandwidth> <wr_bandwidth> <rw_bandwidth>

This is an exemplary command to set the read bandwidth to 16MB/s on malloc0 volume.

$ set_max_qos_limits <ipu_storage_container_platform_ip> 8080 $virtio_blk0 $malloc0 0 0 0 16 0 0

or for device level

$ set_max_qos_limits <ipu_storage_container_platform_ip> 8080 $virtio_blk0 "" 0 0 0 16 0 0
  1. Check if the limit was applied Re-run fio cmd from the fio scenario and observe if QoS settings were applied to virtio-blk device.