layout | title |
---|---|
documentation |
YRD216 - ZWave |
{% include base.html %}
This describes the Z-Wave device YRD216, manufactured by ASSA ABLOY with the thing type UID of yale_yrd216_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The YRD216 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Yale Assure Lock
- Push Button keypad with backlit numbers that won’t wear off
- Mechanical key override
- Manage up to 25 unique codes to share with friends and family
- Weather Protection Gasket
- One-touch locking and keypad wake-up
- Privacy Mode – privacy button located on the interior side of the lock enables users to temporarily disable user codes
- Tamper Resistant Battery Cover
- Tamper Alert – audible alarm sounds if there is an attempt to forcibly remove the lock
- Automatically relocks after 30 seconds
- Simple to install on standard doors and replaces your existing deadbolt in minutes with just a screwdriver
- Certified ANSI/BHMA A156.36, Grade 2
- Lifetime limited warranty for finish and mechanical, one year electronics
To join the lock in a Z-Wave Network (taken from the installation manual)
- Enter the master pin and press #
- Press 7, then #
- Press 1, then #
The lock will now be in inclusion mode.
To exit the Z-Wave Network (taken from the installation manual)
- Enter the master pin and press #
- Press 7, then #
- Press 3, then #
The lock will now be in exclusion mode.
The following table summarises the channels available for the YRD216 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Alarm (raw) | alarm_raw | alarm_raw | String | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Provides alarm parameters as json string.
The alarm_raw
channel is of type alarm_raw
and supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 11 configuration parameters available in the YRD216. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Silent mode | Silent mode on/off |
2 | Auto Relock | Auto Relock on/off |
3 | Auto Relock Time | Auto Relock Time |
4 | Wrong code Entry Limit | Wrong code Entry Limit |
5 | Language | Language |
7 | Shut down time | Shut down time after wrong code entries |
8 | Operating mode | Operating mode |
11 | One touch locking | One touch locking |
12 | Privacy button | Privacy button |
13 | Lock status LED | Lock status LED |
15 | Reset to factory default | Reset to factory default |
Lock Timeout | Sets the time after which the door will auto lock |
Silent mode on/off Default is 1 or High Volume The following option values may be configured -:
Value | Description |
---|---|
1 | Loud |
2 | Quiet |
3 | Off |
The manufacturer defined default value is 1
(Loud).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Auto Relock on/off default is 0x00 or OFF The following option values may be configured -:
Value | Description |
---|---|
0 | Auto relock off |
255 | Auto relock on |
The manufacturer defined default value is 0
(Auto relock off).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Auto Relock Time 10 to 180 seconds (default is 30 seconds) Values in the range 10 to 180 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Wrong code Entry Limit 3 to 10 (default is 5 times) Values in the range 3 to 10 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Language 1=English, 2=Spanish, 3=French (default is 1= English) The following option values may be configured -:
Value | Description |
---|---|
1 | English |
2 | Spanish |
3 | French |
The manufacturer defined default value is 1
(English).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Shut down time after wrong code entries 10 to 180 seconds (default is 60 seconds) Values in the range 10 to 180 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Operating mode
00 = normal mode (this is the default mode)
01 = vacation mode, keypad lockout
02 = privacy mode, no keypad. RF Unlock will work
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal |
1 | Vacation |
2 | Privacy |
The manufacturer defined default value is 0
(Normal).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
One touch locking 0x00 = OFF, 0xFF = ON (default) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Privacy button 0x00 = OFF (default), 0xFF = ON Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Lock status LED 0x00 = OFF (default), 0xFF = ON Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Reset to factory default 01 = Lock will execute Reset To Factory. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The YRD216 supports 1 association group.
Lifeline
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_DOOR_LOCK_V2 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | Linked to BASIC |
COMMAND_CLASS_TIME_V2 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.