This describes the Z-Wave device JTB-1007, manufactured by UFairy G.R. Tech with the thing type UID of ufairy_curtainmotor_00_000
.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The JTB-1007 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
JTB-1007 is a Z-Wave enabled curtain motor.
Click the PB-button once, located near by motor power socket.
Click the PB-button once, located near by motor power socket.
The following table summarises the channels available for the JTB-1007 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Blinds Control | blinds_control | blinds_control | Blinds | Rollershutter |
Provides start / stop control of blinds.
The blinds_control
channel is of type blinds_control
and supports the Rollershutter
item and is in the Blinds
category.
The following table provides a summary of the 9 configuration parameters available in the JTB-1007. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
17 | Motor Open, Go to Direction B | Motor Open, Go to Direction B |
18 | Motor Stop | Motor Stop |
19 | Motor Close, Go to Direction A | Motor Close, Go to Direction A |
20 | Motor Position | Return motor current position |
22 | Motor revert direction | Motor revert direction |
23 | Clear motor lead tail endpoint setting | Clear motor lead tail endpoint setting |
32 | Return motor status flag | Return motor status flag |
33 | Enable manual pulling function | Enable manual pulling function |
34 | Disable manual pulling function | Disable manual pulling function |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Motor Open, Go to Direction B Set only, any value possible Values in the range 0 to 4294967295 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_17_4_wo
and is of type INTEGER
.
This is a write only parameter.
Motor Stop
Values in the range 0 to 4294967295 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_18_4_wo
and is of type INTEGER
.
This is a write only parameter.
Motor Close, Go to Direction A
Values in the range 0 to 4294967295 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_19_4_wo
and is of type INTEGER
.
This is a write only parameter.
Return motor current position
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_20_2
and is of type INTEGER
.
This is a read only parameter.
Motor revert direction
Values in the range 0 to 4294967295 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_22_4_wo
and is of type INTEGER
.
This is a write only parameter.
Clear motor lead tail endpoint setting
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_23_1_wo
and is of type INTEGER
.
This is a write only parameter.
Return motor status flag
<td>
->
</td>
<td>
motor is closing, go to direction A
</td>
<td>
->
</td>
<td>
motor is opening, go to direction B
</td>
<td>
->
</td>
<td>
motor endpoint A has setting
</td>
<td>
->
</td>
<td>
motor endpoint B has setting
</td>
<td>
->
</td>
<td>
(Reserved)
</td>
<td>
->
</td>
<td>
(Reserved)
</td>
<td>
->
</td>
<td>
(Reserved)
</td>
<td>
->
</td>
<td>
direction revert
</td>
1 |
2 |
3 |
4 |
5 |
6 |
7 |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
This is a read only parameter.
Enable manual pulling function
Values in the range 0 to 4294967295 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_33_4_wo
and is of type INTEGER
.
This is a write only parameter.
Disable manual pulling function
Values in the range 0 to 4294967295 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_34_4_wo
and is of type INTEGER
.
This is a write only parameter.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The JTB-1007 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. lifeline group
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.