JTB-1007 Curtain motor

This describes the Z-Wave device JTB-1007, manufactured by UFairy G.R. Tech with the thing type UID of ufairy_curtainmotor_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

JTB-1007 product image

The JTB-1007 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

JTB-1007 is a Z-Wave enabled curtain motor.

Inclusion Information

Click the PB-button once, located near by motor power socket.

Exclusion Information

Click the PB-button once, located near by motor power socket.

Channels

The following table summarises the channels available for the JTB-1007 -:

Channel Name Channel ID Channel Type Category Item Type
Blinds Control blinds_control blinds_control Blinds Rollershutter

Blinds Control

Provides start / stop control of blinds.

The blinds_control channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the JTB-1007. Detailed information on each parameter can be found in the sections below.

Param Name Description
17 Motor Open, Go to Direction B Motor Open, Go to Direction B
18 Motor Stop Motor Stop
19 Motor Close, Go to Direction A Motor Close, Go to Direction A
20 Motor Position Return motor current position
22 Motor revert direction Motor revert direction
23 Clear motor lead tail endpoint setting Clear motor lead tail endpoint setting
32 Return motor status flag Return motor status flag
33 Enable manual pulling function Enable manual pulling function
34 Disable manual pulling function Disable manual pulling function
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 17: Motor Open, Go to Direction B

Motor Open, Go to Direction B Set only, any value possible Values in the range 0 to 4294967295 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_17_4_wo and is of type INTEGER. This is a write only parameter.

Parameter 18: Motor Stop

Motor Stop

Values in the range 0 to 4294967295 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_18_4_wo and is of type INTEGER. This is a write only parameter.

Parameter 19: Motor Close, Go to Direction A

Motor Close, Go to Direction A

Values in the range 0 to 4294967295 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_19_4_wo and is of type INTEGER. This is a write only parameter.

Parameter 20: Motor Position

Return motor current position

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_20_2 and is of type INTEGER. This is a read only parameter.

Parameter 22: Motor revert direction

Motor revert direction

Values in the range 0 to 4294967295 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_22_4_wo and is of type INTEGER. This is a write only parameter.

Parameter 23: Clear motor lead tail endpoint setting

Clear motor lead tail endpoint setting

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_23_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 32: Return motor status flag

Return motor status flag

<td>
    ->  
</td>

<td>
  motor is closing, go to direction A
</td>
<td>
    ->  
</td>

<td>
  motor is opening, go to direction B
</td>
<td>
    ->  
</td>

<td>
  motor endpoint A has setting
</td>
<td>
    ->  
</td>

<td>
  motor endpoint B has setting
</td>
<td>
    ->  
</td>

<td>
  (Reserved)
</td>
<td>
    ->  
</td>

<td>
  (Reserved)
</td>
<td>
    ->  
</td>

<td>
  (Reserved)
</td>
<td>
    ->  
</td>

<td>
  direction revert
</td>
1
2
3
4
5
6
7
This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_32_1 and is of type INTEGER. This is a read only parameter.

Parameter 33: Enable manual pulling function

Enable manual pulling function

Values in the range 0 to 4294967295 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_33_4_wo and is of type INTEGER. This is a write only parameter.

Parameter 34: Disable manual pulling function

Disable manual pulling function

Values in the range 0 to 4294967295 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_34_4_wo and is of type INTEGER. This is a write only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The JTB-1007 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. lifeline group

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2