Skip to content

Latest commit

 

History

History
executable file
·
268 lines (162 loc) · 8.15 KB

tz66d_0_0.md

File metadata and controls

executable file
·
268 lines (162 loc) · 8.15 KB
layout title
documentation
TZ66D - ZWave

{% include base.html %}

TZ66D Dual Paddle Wall Switch

This describes the Z-Wave device TZ66D, manufactured by TKB Home with the thing type UID of tkb_tz66d_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

TZ66D product image

The TZ66D supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The TKB Z-Wave dual wall switch is switching attached loads and is controlled either by the local switching paddle or remotely via the Z-Wave wireless protocol

Inclusion Information

Tap either the top or bottom of the switch once.

Exclusion Information

Tap either the top or bottom of the switch once.

Channels

The following table summarises the channels available for the TZ66D -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the TZ66D. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Ignore start level Ignore start level when transmitting a dim command to the switch
2 Suspend Group 4 Disable transmitting commands to devices in association group 4
3 Blue LED light Behavior Blue LED light Behavior. Default is Night Light (led on when switch off)
4 Invert Switch To change the top of the switch to off and the botton to on
14 Enable Shade Control Group 2 Enable Shade Control Group 2
15 Enable Shade Control Group 3 Enable Shade Control Group 3
19 Blue LED light behavior on transmission Defines the behavior of the blue LED when transmission of data
20 Poll Group 2 Interval (minutes) Polling Interval in minutes (default 2)
22 Poll Group 2 Poll Group 2
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Ignore start level

Ignore start level when transmitting a dim command to the switch

The following option values may be configured -:

Value Description
0 Ignore
1 Don't ignore

The manufacturer defined default value is 1 (Don't ignore).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Suspend Group 4

Disable transmitting commands to devices in association group 4 Setting this parameter will disable transmitting commands to devices in association group 4 The following option values may be configured -:

Value Description
0 Transmit to group 4
1 Disable transmitting to group 4

The manufacturer defined default value is 0 (Transmit to group 4).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Blue LED light Behavior

Blue LED light Behavior. Default is Night Light (led on when switch off) Defines the behavior of the blue LED. Default is Night Light mode where LED is on when switch is off The following option values may be configured -:

Value Description
0 Led on when switch on
1 Night light

The manufacturer defined default value is 0 (Led on when switch on).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

To change the top of the switch to off and the botton to on

The following option values may be configured -:

Value Description
0 ON on top
1 OFF on top

The manufacturer defined default value is 0 (ON on top).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 14: Enable Shade Control Group 2

Enable Shade Control Group 2 Enable the control of shade devices in association group 2 when this option is activated The following option values may be configured -:

Value Description
0 Inactive
1 Shade Control

The manufacturer defined default value is 0 (Inactive).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Enable Shade Control Group 3

Enable Shade Control Group 3 Enable the control of shade devices in association group 3 when this option is activated The following option values may be configured -:

Value Description
0 Inactive
1 Shade Control

The manufacturer defined default value is 0 (Inactive).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 19: Blue LED light behavior on transmission

Defines the behavior of the blue LED when transmission of data

The following option values may be configured -:

Value Description
0 LED does not blinks on activity
1 LED blinks on activity all the time
2 LED blinks on activity 1 second

The manufacturer defined default value is 2 (LED blinks on activity 1 second).

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: Poll Group 2 Interval (minutes)

Polling Interval in minutes (default 2)

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 22: Poll Group 2

Poll Group 2 Defines if the device will poll association Group 2 at the interval defined in parameter 20 The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_22_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TZ66D supports 4 association groups.

Group 1: Group 1

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Group 3: Group 3

Association group 3 supports 5 nodes.

Group 4: Group 4

Association group 4 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.