{% include base.html %}

ZV9001T3-RGBW RGBW 3-Zone Wall Mount Touch Panel

This describes the Z-Wave device ZV9001T3-RGBW, manufactured by Sunricher with the thing type UID of sunricher_zv9001t3rgbw_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZV9001T3-RGBW product image

The ZV9001T3-RGBW supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Product Description

The Wall controller is a Security Enabled Z-Wave Plus device that can both control other Z-Wave devices and activate scenes in Gateways. The wall controller can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Although it is controlling other devices, the device cannot act as Z-Wave network controller (primary or secondary), so a security enabled controller is needed for take full advantage of all functionally for the device. It also supports the Over The Air (OTA) feature for the product’s firmware upgrade. The wall controller has following functions:

  1. Control of groups of other Z-Wave devices using 'ON', 'OFF', Dim and Color Control commands.
  2. Activation of scenes in Gateways.

The encryption modes that the wall controller supports are S0, S2 Unauthenticated. When the wall controller is being included into a Z-Wave network, you can use your primary controller/gateway to enable one encryption mode or disable encryption. (The primary controller/gateway shall support encryption mode configuration).

Product Data

<td>
  908.42 MHz (US)
</td>
<td>
  100-240VAC, 50/60Hz
</td>
<td>
  < 0.5W
</td>
<td>
  0 to 40°C
</td>
<td>
  8% to 80%
</td>
<td>
  75mm x 120mm x 29.1mm
</td>
<td>
  Tempered glass panel with capacitive touch buttons 
</td>
Z-Wave Frequency
Power Supply
Power Consumption
Operating temperature
Relative humidity
Dimensions
Material

Installation Guide

Please read carefully the enclosed user manual before installation of wall controller, in order to ensure an error-free functioning.

The wall controller unit supplied as complete set for flush mounting in the standard US size wall boxes.

ATTENTION: Only authorized technicians under consideration of the country specific installation guidelines/norms may do works with 100-240V mains power. Prior to the assembly of the product, the voltage network has to be switched OFF and ensured against re-switching.

Inclusion Information

Inclusion (Add the device to a Z-Wave network)

  1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).
  2. Make sure the wall controller does not belong to any Z-Wave network (please refer to the part “How to check whether the wall controller included to a network” of this manual).
  3. Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” button for over 3 seconds, the wall controller will be set to inclusion mode, and waiting to be included, then LED indicator turns on and blinks 6 times quickly to indicate successful inclusion.

Once the wall controller quits “inclusion mode”, the LED indicator will turns off. There are 3 ways for wall controller to complete “inclusion mode”:

  1. Automatically quits after successful inclusion.
  2. Quits after 25 seconds timeout.
  3. Press and hold down “ALL ON/OFF” button for over 3 seconds, or short press the “inclusion/exclusion” button to quit.

Exclusion Information

Exclusion (Remove the device from a Z-Wave network)

There are two exclusion methods:

Method 1: Exclusion from the primary controller/gateway:

  1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).
  2. Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” button for over 3 seconds, the wall controller will be set to exclusion mode, and waiting to be excluded, then LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful exclusion.

Once the wall controller quits “exclusion mode”, the LED indicator will turns off.

There are 3 ways for the wall controller to quit “exclusion mode”:

  1. Automatically quits after successful exclusion.
  2. Quits after 25 seconds timeout.
  3. Press and hold down “ALL ON/OFF” button for over 3 seconds, or short press the “inclusion/exclusion” button to quit.

Method 2: Factory reset the wall controller will force the wall controller to be excluded from a network. (please refer to the part “Factory Reset” of this manual)

Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable.

Channels

The following table summarises the channels available for the ZV9001T3-RGBW -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Color Control color_color color_color ColorLight Color
Color Temperature color_temperature color_temperature ColorLight Dimmer
Scene ID scene_number scene_number Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Color Control

The color channel allows to control the color of a light. It is also possible to dim values and switch the light on and off.

The color_color channel is of type color_color and supports the Color item and is in the ColorLight category.

Color Temperature

The color temperature channel allows to set the color temperature of a light from 0 (cold) to 100 (warm).

The color_temperature channel is of type color_temperature and supports the Dimmer item and is in the ColorLight category.

Scene ID

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZV9001T3-RGBW supports 4 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group for commands to Z-Wave network controller

  1. Send “Command Class Device Reset Locally” to associated devices of this group to report factory reset information when factory reset the wall controller.
  2. Double click a group number of the wall controller to send command to associated devices of this group using “Command Class Central Scene”.

Association group 1 supports 1 node.

Group 2: Launch 1

Association group for nodes in zone 1

Press button "1" to activate group.

  1. Press and hold down button "1" to switch the associated devices with a Basic Set commands.
  2. Press PWM1-PWM4 buttons, direct control of associated devices using Color Switch Set commands.
  3. Press and hold down PWM1-PWM4 buttons, direct control of associated devices using Color Switch Start Level Change commands.
  4. Short touch or slide touch the “Color Wheel”, direct control of associated devices using Color Switch Set commands.
  5. Press and hold down brightness button, direct control of associated devices using Multilevel Switch Start Level Change commands.
  6. Short press "play/pause" button, direct control of associated devices using Configuration Set commands with Parameter Number = 5, Size = 1, toggling through values (1-0-2-0-3-0-4-0-5-0-6-0-1-...).
  7. Press and hold down "play/pause" button direct control of associated devices using Configuration Set commands with Parameter Number = 6, Size = 1 with varying values

Association group 2 supports 12 nodes.

Group 3: Launch 2

Association group for nodes in zone 2

Press button "2" to activate group.

  1. Press and hold down button "2" to switch the associated devices with a Basic Set commands.
  2. Press PWM1-PWM4 buttons, direct control of associated devices using Color Switch Set commands.
  3. Press and hold down PWM1-PWM4 buttons, direct control of associated devices using Color Switch Start Level Change commands.
  4. Short touch or slide touch the “Color Wheel”, direct control of associated devices using Color Switch Set commands.
  5. Press and hold down brightness button, direct control of associated devices using Multilevel Switch Start Level Change commands.
  6. Short press "play/pause" button, direct control of associated devices using Configuration Set commands with Parameter Number = 5, Size = 1, toggling through values (1-0-2-0-3-0-4-0-5-0-6-0-1-...).
  7. Press and hold down "play/pause" button direct control of associated devices using Configuration Set commands with Parameter Number = 6, Size = 1 with varying values

Association group 3 supports 12 nodes.

Group 4: Launch 3

Association group for nodes in zone 3

Press button "3" to activate group.

  1. Press and hold down button "3" to switch the associated devices with a Basic Set commands.
  2. Press PWM1-PWM4 buttons, direct control of associated devices using Color Switch Set commands.
  3. Press and hold down PWM1-PWM4 buttons, direct control of associated devices using Color Switch Start Level Change commands.
  4. Short touch or slide touch the “Color Wheel”, direct control of associated devices using Color Switch Set commands.
  5. Press and hold down brightness button, direct control of associated devices using Multilevel Switch Start Level Change commands.
  6. Short press "play/pause" button, direct control of associated devices using Configuration Set commands with Parameter Number = 5, Size = 1, toggling through values (1-0-2-0-3-0-4-0-5-0-6-0-1-...).
  7. Press and hold down "play/pause" button direct control of associated devices using Configuration Set commands with Parameter Number = 6, Size = 1 with varying values

Association group 4 supports 12 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SWITCH_COLOR_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1