layout | title |
---|---|
documentation |
11-01-011 - ZWave |
{% include base.html %}
This describes the Z-Wave device 11-01-011, manufactured by Sensative AB with the thing type UID of sensative_1101011_00_000
.
The device is in the category of Sensor, defining Device used to measure something.
The 11-01-011 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The 11-01-011 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Strips is a Z-Wave magnet sensor that can be added to any certified Z-Wave system and operate with any brand Z-Wave device.
- Set your controller in inclusion mode (see your controller’s manual).
- Follow the instruction for Wake up.
- A long LED blink indicates that the inclusion was successful.
- Set your controller in exclusion mode (see your controller’s manual).
- Follow the instruction for Wake up.
- A long LED blink indicates that the exclusion was successful.
The 11-01-011 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Wake up Strips manually for Z-Wave communication.
- Place the round magnet at the rounded edge.
- When the LED blinks, move the magnet away.
- Repeat 3 times in total within 10 seconds.
It may be necessary to repeat this process several times to make changes take affect.
Note that wakeup period can only be set to a minimum period of 30 minutes.
The following table summarises the channels available for the 11-01-011 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Sensor | sensor_door | sensor_door | Door | Contact |
Tamper Alarm | alarm_tamper | alarm_tamper | Switch | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Indicates if the door/window is open or closed.
The sensor_door
channel is of type sensor_door
and supports the Contact
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Contact
item type -:
Value | Label |
---|---|
OPEN | Open |
CLOSED | Closed |
Indicates if the tamper alarm is triggered.
The alarm_tamper
channel is of type alarm_tamper
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 2 configuration parameters available in the 11-01-011. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Notification type | Define the notification type. |
2 | LED indication | Specify if LED should indicate special event. |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Define the notification type.
The following option values may be configured -:
Value | Description |
---|---|
0 | Binary Sensor report |
1 | Notification report |
2 | Basic report |
The manufacturer defined default value is 1
(Notification report).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Specify if LED should indicate special event.
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(On).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 11-01-011 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.