This describes the Z-Wave device SK-3007-05, manufactured by Shenzhen Saykey Technology with the thing type UID of saykey_sk300705_00_000
.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The SK-3007-05 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The SK-3007-05 external module extends traditional curtain motors with zwave capability.
- Connect power supply to motor and connect the external module to motor external connector, and Make sure the module is located within direct range of the Z-Wave controller.
- Set the controller into the inclusion/add mode (refer to controller’s operating manual).
- Click the PB-button triple times in 1.5 second, located left side of the motor external box.
- Curtain motor will be detected and included in the Z-Wave network.
- Connect power supply to motor and connect the external module to motor external connector, and Make sure the module is located within direct range of the Z-Wave controller.
- Set the controller into the exclusion/remove mode (refer to controller’s operating manual).
- Click the PB-button triple times in 1.5 second, located left side of the motor external box.
- Curtain motor will be detected and excluded from the Z-Wave network.
The following table summarises the channels available for the SK-3007-05 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Blinds Control | blinds_control | blinds_control | Blinds | Rollershutter |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Provides start / stop control of blinds.
The blinds_control
channel is of type blinds_control
and supports the Rollershutter
item and is in the Blinds
category.
The following table provides a summary of the 5 configuration parameters available in the SK-3007-05. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
4 | Current Motor Position | Current Motor Position |
6 | Set motor direction | Toggle motor direction between reverse and default |
7 | Clear motor lead tail endpoint setting | Clear motor lead tail endpoint setting |
8 | Enable manual pull function | Enable manual pull function |
9 | Disable manual pull function | Disable manual pull function |
Current Motor Position Support Get only, feedback motor current position(0x00-0x63, 0xFE) Values in the range -127 to 99 may be set.
The manufacturer defined default value is -127
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
This is a read only parameter.
Toggle motor direction between reverse and default Support Set only. Toggle motor direction between reverse and default as send out set command with any value (0x00-0xFF). Values in the range -128 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_6_1_wo
and is of type INTEGER
.
This is a write only parameter.
Clear motor lead tail endpoint setting Support Set only. Clear motor lead tail endpoint setting as send out set command with any value (0x00-0xFF). Values in the range -128 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_7_1_wo
and is of type INTEGER
.
This is a write only parameter.
Enable manual pull function Support Set only. Enable manual pull function as send out set command with any value (0x00-0xFF). Values in the range -128 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_1_wo
and is of type INTEGER
.
This is a write only parameter.
Disable manual pull function Support Set only. Disable manual pull function as send out set command with any value (0x00-0xFF). Values in the range -128 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_9_1_wo
and is of type INTEGER
.
This is a write only parameter.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The SK-3007-05 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline, is assigned to send motor lifeline status to associated devices, including send the multilevel report frame while window cover position, send device local reset frame while set factory default manually etc.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |