700854 Solar Powered Outdoor Siren

This describes the Z-Wave device 700854, manufactured by Popp & Co with the thing type UID of popp_700854_02_004. This version of the device is limited to firmware versions above 2.4

The device is in the category of Battery, defining Batteries, Energy Storages.

700854 product image

The 700854 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

This solar powered outdoor siren can be used without any additional power supply or batteries. It can be installed on any place on the outside of the house and can be controlled using Z-Wave. The device will issue a very loud sound (105 dBm) and in parallel some stroboscope light as well. The siren is self-protecting. Removing the main device from the mounting unit immediately starts the siren and also reports the tamper attempt to the ZWave central controller. All communication between the Z-Wave controller and the siren is encrypted and secured to protect against manipulation.

Thanks to the large solar panel, the siren can be mounted on nearly every place outside the house where it"s recommended to place it in indirect sun light to prevent strong heating-up the housing. The siren is maintenance-free and water-proofed (IP56). The average solar energy of one day keeps the device alive for up to 50 days (without using the siren). Additionally, an internal temperature sensor reports the temperature inside the siren’s enclosure.

Inclusion Information

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

  1. Open the case and turn on the power switch 
  2. Remove the metal mounting plate from the device. 
  3. Turn your controller into inclusion mode with a short single click on the internal inclusion button.

Exclusion Information

  1. Open the case and turn on the power switch 
  2. Remove the metal mounting plate from the device. 
  3. Turn your controller into inclusion mode with a short single click on the internal inclusion button.

General Usage Information

The siren can be turned on and off using wireless commands. To protect this communication from misuse is strongly recommended to operate the siren in secure communication mode. The secure communication is activated on default during inclusion unless explicitly suppressed. When activated the siren will generate a 105 dB alarm sound and a flash light. This behavior can be configured as well using configuration parameter 5. Make sure to deactivate the tamper protection before removing an included siren from the mounting plate.

It is possible to power the Siren from an external power supply. Please use any 12 V DC power with minimum of 1 W output. The terminals marked with E ( see ill1 for more details) allows to connect the power source to the device. its recommended ot detach the cables to the solar cell in this operating mode.

Channels

The following table summarises the channels available for the 700854 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
TAMPER sensor_binary sensor_binary Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Alarm alarm_general alarm_general Alarm Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Battery Level battery-level system.battery_level Battery Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

TAMPER

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the 700854. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Siren Tamper Mode Sets the tamper triggering mode when removed from the holder
5 Siren mode Determines how the Siren shall react on alarm
6 Auto Off If the value is set, the siren will be switched off automatically.

Parameter 1: Siren Tamper Mode

Sets the tamper triggering mode when removed from the holder

The following option values may be configured -:

Value Description
0 Trigger, when removed from holder
1 Triggers automatically
2 not trigger

The manufacturer defined default value is 0 (Trigger, when removed from holder).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 5: Siren mode

Determines how the Siren shall react on alarm

The following option values may be configured -:

Value Description
0 Siren Only
1 Flash Only
2 Flash plus Siren

The manufacturer defined default value is 2 (Flash plus Siren).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Auto Off

If the value is set, the siren will be switched off automatically.

<td>
  No Auto Off
</td>
<td>
  after X Minutes
</td>
1 - 127
Values in the range 0 to 127 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 700854 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association - one device controls an other device Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Documentation Links