{% include base.html %}

009402 10 Year Smoke Detector with Siren Function

This describes the Z-Wave device 009402, manufactured by Popp & Co with the thing type UID of popp_009402_01_014. This version of the device is limited to firmware versions above 1.14

The device is in the category of Smoke Detector, defining Smoke detectors.

009402 product image

The 009402 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

This product combines a certified '10 year' stand-alone smoke detector with a plug-in Z-Wave module to form a wirelessly reporting automatically meshing smoke sensor plus wirelessly controllable indoor siren. The smoke detector’s sensor head is certified with the Q quality label, conforms DIN EN 14604 and satisfies all contemporary legal requirements.

The High-End 10-years smoke detector offers a large test button conveniently accessible even with a broomstick when mounted on the sealing. The smoke chamber is monitored electronically to avoid any malfunction and wrong alerts. The device will also report its end of life to make sure it is getting replaced on time.

Furthermore, the device can be used as an independent indoor siren within the Z-Wave network, which can alarm in case of detected flood or burglary. Please consider that the additional siren function will influence battery lifetime!

The smoke sensor and the Z-Wave controller communicate via a secure protocol to prevent manipulation.

Inclusion Information

  • Pressing the Z-Wave button includes the device.
  • If the button is pressed for at least 3 seconds, the inclusion will be done without the Security Command Class.

Exclusion Information

 A single click on the  Z-Wave button will exclude the device. 

Channels

The following table summarises the channels available for the 009402 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Binary Sensor sensor_binary sensor_binary Switch
Alarm (system) alarm_system alarm_system Switch
Alarm (smoke) alarm_smoke alarm_smoke Smoke Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Battery Level battery-level system.battery_level Battery Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Alarm (system)

Indicates if a system alarm is triggered.

The alarm_system channel is of type alarm_system and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (smoke)

Indicates if a smoke is triggered.

The alarm_smoke channel is of type alarm_smoke and supports the Switch item and is in the Smoke category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the 009402. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Siren alarm sequence interval Siren alarm sequence interval
2 Siren alarm tone length Siren alarm tone length
3 Value of On-Command
4 Value of Off-Command
10 Auto Report Battery Time Auto Report Battery Time

Parameter 1: Siren alarm sequence interval

Siren alarm sequence interval The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly  off.

This parameter defines the total length of the interval in seconds. Values in the range 3 to 129 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Siren alarm tone length

Siren alarm tone length The  additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly  off.

This parameter defines the total  length of the sound versus silence within this interval. Values in the range 1 to 99 may be set.

The manufacturer defined default value is 8.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Value of On-Command

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Value of Off-Command

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 10: Auto Report Battery Time

Auto Report Battery Time The interval time for auto report the battery level. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 127.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 009402 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 4 nodes.

Group 2: Alarm Reports

Association group 2 supports 4 nodes.

Group 3: Switching Command when Alarm

Association group 3 supports 4 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V5
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.