layout | title |
---|---|
documentation |
CA8900 - ZWave |
{% include base.html %}
This describes the Z-Wave device CA8900, manufactured by Intermatic with the thing type UID of intermatic_ca8900_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The CA8900 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
ThermostatEasy energy saving buttons (NORM / SAVE)
- Easy Mode Switching Buttons (HEAT/OFF/COOL)
- Can be used with all 24VAC heating and cooling systems. It cannot be used with line voltage systems.
- Is Digital and your desired heat or cool temperatures can easily be set on the large screen with the TEMP UP (+) and TEMP DOWN (-) buttons on the front.
- A minimum 4-minute off time protects heating and cooling systems from damage.
- Uses a new technique called sequential staging for more comfort with faster reaction to requested temperature changes.
- Battery Backup with 2 x "AA" batteries (included)
Press and release the BIND button.
Press and release the BIND button.
The following table summarises the channels available for the CA8900 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.