layout title
documentation
GE 28169 / Jasco 28168 - ZWave

{% include base.html %}

GE 28169 / Jasco 28168 Plug in Smart Switch

This describes the Z-Wave device GE 28169 / Jasco 28168, manufactured by Jasco Products with the thing type UID of ge_28169_00_000. This version of the device is limited to firmware versions below 4.9

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

GE 28169 / Jasco 28168 product image

The GE 28169 / Jasco 28168 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-wave controlled AC outlet for standard incandescent lighting, CFL/LEDs, fans or small appliances.
Must not exceed 600 watts (Incandescent); 1800W (15A) Resistive or ½ HP Motor

Inclusion Information

Put controller into inclusion mode, single press and release the manual/program button on the smart switch to include it in the network

Exclusion Information

Put controller into exclusion mode, single press and release the manual/program button on the smart switch to exclude it from the network

Channels

The following table summarises the channels available for the GE 28169 / Jasco 28168 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the GE 28169 / Jasco 28168. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 LED Light Set the state of the LED Light
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: LED Light

Set the state of the LED Light

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 LED Light on when Z-Wave turned OFF (Default)
1 LED Light on when Z-Wave turned On
2 LED Light Always Off

The manufacturer defined default value is 0 (LED Light on when Z-Wave turned OFF (Default)).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The GE 28169 / Jasco 28168 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links