This describes the Z-Wave device RFTR9505, manufactured by Cooper Wiring Devices with the thing type UID of cooper_rftr9505_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The RFTR9505 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The Aspire RF 15A split receptacle replaces regular receptacles to provide local and remote RF ON/OFF control of a single outlet. Moreover, the Aspire RF receptacle provides other programmable functions (scenes, events, association, child lockout, etc.) when used with Aspire RF or other Z-Wave® compliant controllers*. The receptacle can be manually and remotely controlled by commands sent from an Aspire RF controller (RFHDCSG, RFTDCSG, RFTCP, RFUSB-PRO) or other Z-Wave compatible controllers or programs. An Aspire RF receptacle utilizes existing 120 V/AC 60Hz standard house wiring and fits into a standard wallbox. No new wiring needed.*Note: some specific Aspire RF features may not be programmable
Press the Install button
Press the Install button
The following table summarises the channels available for the RFTR9505 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 4 configuration parameters available in the RFTR9505. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | Panic ON time | Panic ON time |
3 | Panic OFF time | Panic OFF time |
5 | Power Up State | Power up state of the device after power loss |
6 | Panic mode enable | Enables this device to participate in panic mode |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Panic ON time The amount of time in seconds the switch will turn on for when panic mode is triggered.
<td>
<strong>Time</strong>
</td>
<td>
0 to 127 seconds
</td>
<td>
128 to 255 seconds
</td>
Value |
0 to 127 |
-128 to -1 |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Panic OFF time The amount of time in seconds the switch will turn off when panic mode is triggered.
<td>
<strong>Time</strong>
</td>
<td>
0 to 127 seconds
</td>
<td>
128 to 255 seconds
</td>
Value |
0 to 127 |
-128 to -1 |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Power up state of the device after power loss
The following option values may be configured -:
Value | Description |
---|---|
1 | Off |
2 | On |
3 | Last state |
The manufacturer defined default value is 3
(Last state).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Enables this device to participate in panic mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 0
(OFF).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The RFTR9505 supports 1 association group.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_HAIL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |