RFTR9505 Duplex receptacle

This describes the Z-Wave device RFTR9505, manufactured by Cooper Wiring Devices with the thing type UID of cooper_rftr9505_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

RFTR9505 product image

The RFTR9505 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The Aspire RF 15A split receptacle replaces regular receptacles to provide local and remote RF ON/OFF control of a single outlet. Moreover, the Aspire RF receptacle provides other programmable functions (scenes, events, association, child lockout, etc.) when used with Aspire RF or other Z-Wave® compliant controllers*. The receptacle can be manually and remotely controlled by commands sent from an Aspire RF controller (RFHDCSG, RFTDCSG, RFTCP, RFUSB-PRO) or other Z-Wave compatible controllers or programs. An Aspire RF receptacle utilizes existing 120 V/AC 60Hz standard house wiring and fits into a standard wallbox. No new wiring needed.*Note: some specific Aspire RF features may not be programmable

Inclusion Information

Press the Install button

Exclusion Information

Press the Install button

Channels

The following table summarises the channels available for the RFTR9505 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm alarm_general alarm_general Alarm Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the RFTR9505. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Panic ON time Panic ON time
3 Panic OFF time Panic OFF time
5 Power Up State Power up state of the device after power loss
6 Panic mode enable Enables this device to participate in panic mode
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 2: Panic ON time

Panic ON time The amount of time in seconds the switch will turn on for when panic mode is triggered. 

<td>
  <strong>Time</strong>
</td>
<td>
  0 to 127 seconds
</td>
<td>
  128 to 255 seconds
</td>
Value
0 to 127
-128 to -1
This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -128 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Panic OFF time

Panic OFF time The amount of time in seconds the switch will turn off when panic mode is triggered. 

<td>
  <strong>Time</strong>
</td>
<td>
  0 to 127 seconds
</td>
<td>
  128 to 255 seconds
</td>
Value
0 to 127
-128 to -1
This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -128 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 5: Power Up State

Power up state of the device after power loss

The following option values may be configured -:

Value Description
1 Off
2 On
3 Last state

The manufacturer defined default value is 3 (Last state).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Panic mode enable

Enables this device to participate in panic mode

The following option values may be configured -:

Value Description
0 Off
1 On

The manufacturer defined default value is 0 (OFF).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The RFTR9505 supports 1 association group.

Group 1: Group 1

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_HAIL_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_INDICATOR_V1

Documentation Links