[Producer.ni_mimosa]
NiIPaddr = 192.168.22.2
[Producer.aida_tlu]
# you can use this to track your changes, e.g. using the date
initid = 20180925
TLUmod= "1e"
# Path on the PC with TLU Producer and relative path is starting path euRun!
ConnectionFile = "file:///opt/eudaq2/user/eudet/misc/hw_conf/aida_tlu/aida_tlu_connection.xml"
# relative path from execution directory
#ConnectionFile = "file://../hw_conf/aida_tlu/aida_tlu_connection.xml"
# ControlHub is recommended for Ubuntu, the name is the name in the conncetion file
DeviceName = "aida_tlu.controlhub"
#DeviceName = "aida_tlu.udp"
# Set CONFCLOCK to 1 to configure clock, which is necessary after a power cycle
CONFCLOCK = 1
# Path to clock file
CLOCK_CFG_FILE = "/opt/eudaq2/user/eudet/misc/hw_conf/aida_tlu/aida_tlu_clk_config.txt"
# Set skipini to 1, if you want to skip the init-step
skipini = 0
# further expert setting, do not change
nDUTs = 4 # number of HDMI inputs, leave 4 even if you only use fewer inputs
nTrgIn = 6
intRefOn = 0 # 0 = False (Internal Reference OFF), 1 = True
VRefInt = 2.5
VRefExt = 1.3
I2C_COREEXP_Addr = 0x21 # I2C address of the bus expander on Enclustra FPGA
I2C_CLK_Addr = 0x68 # I2C address of the Si5345
I2C_DAC1_Addr = 0x13 # I2C address of 1st AD5665R
I2C_DAC2_Addr = 0x1F # I2C address of 2nd AD5665R
I2C_ID_Addr = 0x50 # I2C address of unique Id number EEPROM
I2C_EXP1_Addr = 0x74 # I2C address of 1st expander PCA9539PW
I2C_EXP2_Addr = 0x75 # I2C address of 2nd expander PCA9539PW
[LogCollector.log]
# Currently, all LogCollectors have a hardcoded runtime name: log
# the $12D will be converted a data/time string with 12 digits.
EULOG_GUI_LOG_FILE_PATTERN = /opt/eudaq2/log/log_$12D.log
[DataCollector.one_dc]
# nothing
[Monitor.my_mon]
# nothinga
[Producer.USBpixI4]
# name hardcoded, this is for version 5.3, this happens all in the ini step
#[Producer.USBpix] # name hardcoded, this is for version 6.2
# config file with proper paths for TB22
config_file = /opt/eudaq2/user/eudet/misc/hw_conf/fei4_stcontrol/180924_fei4b_desy_system_5.3.cfg.root
# see in OnlineMonitor distribution, adjusted to mean - maybe right, maybe not
lvl1_delay = 21
SRAM_READOUT_AT = 10
SWAP_XY = 1