ergoCub 1.3 S/N:002 β l_middle_oc and r_ring_pinky_oc do not move full range #2010
Comments
Now also the right middle OC gets stuck from time to time when opening |
Maintenance successfully completed IMG_5118.MOVIMG_5119.MOV |
The problem only persists in the middle, unfortunately the phalanx broke and needs to be replaced. We will update the issue when we are able to do the intervention |
Hi @S-Dafarra , after that @edersonferrante replaced the middle finger phalanx I calibrated and tested the finger. Everything seems working properly. Closing ! π |
Robot Name π€
ergoCub 1.3 S/N:002
Request/Failure description
The left middle finger reads 60deg but it is fully stretched. Then, when setting the refence to 90deg, it closes
The right pinky finger instead closes at most 22 deg and then it stops.
Detailed context
It seems that the situation got worse and worse after a few hours of usage.
Additional context
No response
How does it affect you?
No response
The text was updated successfully, but these errors were encountered: