iCubErzelli01 S/N:032 – Left thumb tendon broken #1976

Closed
ddetommaso opened this issue Nov 28, 2024 · 8 comments
Closed

iCubErzelli01 S/N:032 – Left thumb tendon broken #1976

ddetommaso opened this issue Nov 28, 2024 · 8 comments
Assignees
Labels
iCubErzelli01 S/N:032 pinned This label prevents an issue from being closed automatically

Comments

@ddetommaso
Copy link

ddetommaso commented Nov 28, 2024

Robot Name πŸ€–

iCubErzelli01 S/N:032

Request/Failure description

One of the tendon of the left thumb seems to be broken.

Detailed context

While playing arm movements the thumb just broke.
log_icub-head_yarprobotinterface_2133.txt

Additional context

Image
Image

How does it affect you?

It is not causing severe impact on data collection for the current experiment, but it might create it for the following one.

@github-actions github-actions bot changed the title Right thumb tendon broken iCubErzelli01 S/N:032 – Right thumb tendon broken Nov 28, 2024
Copy link

This issue has been automatically marked as stale because it did not have recent activity. It will be closed if no further activity occurs.

@github-actions github-actions bot added the stale This issue will be soon closed automatically label Jan 28, 2025
@AntonioConsilvio AntonioConsilvio added pinned This label prevents an issue from being closed automatically and removed stale This issue will be soon closed automatically labels Jan 28, 2025
@ddetommaso
Copy link
Author

Hi @AntonioConsilvio

let me update this about the impact because, after two months we open the issue, it became quite urgent since we will need to start experiment in the next couple of weeks.

@filippoborgogni
Copy link

Hi @ddetommaso , tomorrow @edersonferrante and I will come to work on the robot to try to solve this issue and this one #1942

@ddetommaso
Copy link
Author

Hi @filippoborgogni,

thank you for taking care of this. As previously mentioned to @AntonioConsilvio, tomorrow I will be out of the office to follow another activity, but he ensured me that you can fix the issue autonomously. Please, after the fix, ensure that the robot is fully functional.

Thank you

@filippoborgogni
Copy link

Hi @ddetommaso , yesterday @edersonferrante and I replaced the left thumb proximal that was broken. We tried it mechanically, with the JOGGER board and with the yarprobotinterface we tested all the joints of the left thumb.
In the video below you can see that it worked properly.

MicrosoftTeams-video.mp4

We wait your feedback to close this issue. Thanks!

cc @AntonioConsilvio

@filippoborgogni filippoborgogni moved this from Triage to Review/QA in iCub Tech Support Feb 6, 2025
@ddetommaso
Copy link
Author

Hi @filippoborgogni

unfortunately we cannot still close this issue because after the fixing it seems that now the left wrist is not calibrating.
It was enough to do a few rounds of complete calibration of the robot to notice this problem.

log_icub-head_yarprobotinterface_1148.txt

We would need the robot functioning for the school day happening next Tuesday, could you please come in the next following days to finalize this?

Thank you

cc @AntonioConsilvio @maggia80

@filippoborgogni
Copy link

Today @edersonferrante and I went back to fix this issue.
We found a couple of unsoldered cables from the AEA board, we reconnected the cables and we verified that the wrist is working correctly (as you can see in the video below).
We also found a problem on the encoder (hall sensor) of the proximal index tendon: so we found some unsoldered cables on the MAIS board, we fixed it and we verified that the sensor was reading correctly (the video shows the correct reading).

video.polso.mov
hall.sensor.mov

After that, with @ddetommaso , we tested the robot and it worked properly.
Closing! πŸš€

cc @AntonioConsilvio

@github-project-automation github-project-automation bot moved this from Review/QA to Done in iCub Tech Support Feb 7, 2025
@maggia80 maggia80 changed the title iCubErzelli01 S/N:032 – Right thumb tendon broken iCubErzelli01 S/N:032 – Left thumb tendon broken Feb 8, 2025
@maggia80
Copy link
Contributor

maggia80 commented Feb 8, 2025

edited since it was left thumb

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
iCubErzelli01 S/N:032 pinned This label prevents an issue from being closed automatically
Projects
Status: Done
Development

No branches or pull requests

4 participants