Skip to content
This repository has been archived by the owner on Apr 1, 2024. It is now read-only.

More than 4 RPDOs and 4 TPDOs #58

Closed
ryanpdx opened this issue May 3, 2021 · 1 comment
Closed

More than 4 RPDOs and 4 TPDOs #58

ryanpdx opened this issue May 3, 2021 · 1 comment
Assignees

Comments

@ryanpdx
Copy link
Member

ryanpdx commented May 3, 2021

On OreSat, more than 4 RPDOs and 4 TPDOs are need by a device.

How the OreSat device software handles it:
Every device is given the space for 4 NODE-IDs. So if a boards is given NODE-ID 0x12, nodes 0x13, 0x14, & 0x15 will never exist and their TPDOs and TPDOs will be use by the 0x12 node. There for all devices on OreSat have up to 16 RPDOs and 16 TPDOs.

All COB-ID in the OD for the PDOs will be the COB-ID for node 0x00 (0x180, 0x280, etc) and the device software will add the NODE-ID and a offset to the COB-ID from the OD, unless a specific COB-ID is wanted. So if the COB-ID is NOT 0x180, 0x280, etc the device software will NOT add the NODE-ID and a offset to the COB-ID from the OD. The offset it the difference between the NODE-ID of the device and the default NODE-ID for that specific RPDO/TPDO.

Example with NODE-ID 0x11 and 6 TPDOs:
COB-ID from OD: 0x180, 0x284, 0x380, 0x480, 0x180, & 0x280
COB-ID with changes: 0x191, 0x284, 0x391, 0x491, 0x192, & 0x292

Notes

  • This doesn't really follow a standard.
  • May be good to not expect exactly 16 RPDOs and 16 TPDOs in OD (make it more generalized)
  • How this works may change if OreSat swaps to using Lely-CANopen instead of CANopenNode.

Example DCF file: battery.txt

@dmitri-mcguckin dmitri-mcguckin added the awaiting dependency Waiting for something else to be done before this can be acomplished. label May 24, 2021
@dmitri-mcguckin
Copy link
Member

Will complete as a part of Feature #67.