a 30706 DAKAE.MAC

PDP-10 KA10 Basic Instruction Diagnostic #5

The PDP-10 KA10 Basic Instruction Diagnostic #5 (MAINDEC-10-DAKAE) test code has been extracted from DAKAEM.MAC [original] for use with the PDP-10 Test Machine with Debugger below.

This diagnostic "TESTS THE FWT, ADD/SUB, PC CHANGE AND COMPARE INSTRUCTIONS."

Resources for this diagnostic include:

{% include machine.html id="testka10" %}

The Debugger's assemble ("a") command can be used to test the new built-in MACRO-10 Mini-Assembler, which supports a subset of the MACRO-10 assembly language.

This command:

a 30706 DAKAE.MAC

will automatically read the DAKAE.MAC source file (a slightly modified copy of DAKAEM.MAC), assemble it, and then load the binary output at the specified address.


DAKAE.TXT

				IDENTIFICATION
				--------------

	PRODUCT CODE:       AH-6859C-DD

	DIAGNOSTIC CODE:    DAKAE

	PRODUCT NAME:       DAKAEC0 DECSYSTEM10 PDP-10 KA10 BASIC
	                    INSTRUCTION DIAGNOSTIC (5)

	VERSION:            0.3

	DATE RELEASED:      JANUARY 1979

	MAINTAINED BY:      DIAGNOSTIC ENGINEERING

	AUTHOR:             BILL SCORZELLI

		        COPYRIGHT (C) 1967, 1979

	        DIGITAL EQUIPMENT CORPORATION, MAYNARD, MASS.

	THIS SOFTWARE IS FURNISHED UNDER A LICENSE FOR  USE  ONLY  ON  A
	SINGLE COMPUTER SYSTEM AND MAY BE COPIED ONLY WITH THE INCLUSION
	OF THE ABOVE COPYRIGHT NOTICE.   THIS  SOFTWARE,  OR  ANY  OTHER
	COPIES  THEREOF, MAY NOT BE PROVIDED OR OTHERWISE MADE AVAILABLE
	TO ANY OTHER PERSON EXCEPT FOR USE ON SUCH SYSTEM AND TO ONE WHO
	AGREES  TO  THESE  LICENSE TERMS.  TITLE TO AND OWNERSHIP OF THE
	SOFTWARE  SHALL  AT   ALL  TIMES  REMAIN  IN  DIGITAL  EQUIPMENT
	CORPORATION.

	THE INFORMATION IN THIS DOCUMENT IS SUBJECT  TO  CHANGE  WITHOUT
	NOTICE  AND  SHOULD  NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL
	EQUIPMENT CORPORATION.

	DIGITAL EQUIPMENT CORPORATION ASSUMES NO  RESPONSIBILITY FOR THE
	USE  OR  RELIABILITY  OF  ITS SOFTWARE IN EQUIPMENT WHICH IS NOT
	SUPPLIED BY DIGITAL EQUIPMENT CORPORATION.
	
							MAINDEC-10-DAKAE.TXT
							PAGE 2


			TABLE OF CONTENTS
			-----------------

1.0	ABSTRACT

2.0	REQUIREMENTS

2.1	EQUIPMENT

2.2	STORAGE

2.3	PRELIMINARY PROGRAMS

3.0	PROGRAM PROCEDURES

3.1	LOADING PROCEDURE

3.2	STARTING PROCEDURE

3.3	OPERATING PROCEDURE

4.0	ERRORS

5.0	ITERATION COUNTER

6.0	CYCLE TIME

7.0	OPERATIONAL VARIATIONS

8.0	MISCELLANEOUS

9.0	LISTING

							MAINDEC-10-DAKAE.TXT
							PAGE 3


1.0	ABSTRACT

	THIS PDP-10 KA10 BASIC INSTRUCTION DIAGNOSTIC IS THE
	FIFTH IN A SERIES OF PDP-10 KA10 PROCESSOR DIAGNOSTICS.
	THE DIAGNOSTIC TESTS THE FWT, ADD/SUB, PC CHANGE
	AND COMPARE INSTRUCTIONS.

2.0	REQUIREMENTS

2.1	EQUIPMENT

	A PDP-10 KA10 WITH A MINIMUM OF 32K OF MEMORY

	PAPER TAPE READER
	DECTAPE (OPTIONAL)
	CONSOLE TELETYPE

2.2	STORAGE

	THE PROGRAM RUNS WITHIN 32K OF MEMORY.

2.3	PRELIMINARY PROGRAMS

	CONSOLE FUNCTIONS WORKING PROPERLY
	PAPER-TAPE OR DECTAPE READ-IN WORKING PROPERLY
	PREVIOUS PROCESSOR DIAGNOSTICS

							MAINDEC-10-DAKAE.TXT
							PAGE 4


3.0	PROGRAM PROCEDURES

3.1	LOADING PROCEDURE

	PAPER TAPE - HARDWARE READ-IN (READER DEVICE CODE 104)
	DECTAPE - LOAD WITH DIAMON (DECTAPE DEVICE CODE 320)

3.2	STARTING PROCEDURE

	STAND-ALONE STARTING ADDRESS IS 30000.

	IF THE DIAGNOSTIC FAILS TO START CORRECTLY TRY STARTING AT THE
	FIRST TEST INSTEAD OF AT THE BEGINNING OF THE CONTROL SEQUENCE.
	(SEE LISTING).

3.3	OPERATING PROCEDURE

	ONCE STARTED THE PROGRAM WILL CYCLE CONTINUALLY UNTIL STOPPED
	OR AN ERROR OCCURS.

4.0	ERRORS

	ERRORS ARE IN THE FORM OF HALT INSTRUCTIONS.  THE LISTING
	SHOULD BE CONSULTED TO DETERMINE THE CAUSE OF THE ERROR.  A
	NO OPERATION (JUMP) INSTRUCTION FOLLOWS EACH HALT.  THIS
	MAY BE USEFUL IN CONSTRUCTING A SCOPE LOOP TO CYCLE ON THE
	FAILING INSTRUCTION.

5.0	ITERATION COUNTER

	THE ITERATION COUNT OF THE PROGRAM IS DISPLAYED IN THE MEM-
	ORY INDICATORS (MI).  THIS COUNT IS A DECREMENTING COUNT AND
	INITIALLY STARTS AT -1 IN STAND-ALONE OPERATION.

6.0	CYCLE TIME

	THE CYCLE TIME OF THE PROGRAM IS IN THE MILLISECOND RANGE AND
	IS THEREFORE SUITABLE FOR TAKING MARGINS, VIBRATION TESTS, ETC.

							MAINDEC-10-DAKAE.TXT
							PAGE 5


7.0	OPERATIONAL VARIATIONS

	A.  DIAGNOSTIC MONITOR

	    THE PROGRAM IS USABLE WITH THE DIAGNOSTIC MONITOR TO PRO-
	    VIDE RELIABILITY TESTS, ACCEPTANCE TESTS, AND/OR TO PRO-
	    VIDE A QUICK METHOD OF ISOLATION OF A FAULT TO A PARTICULAR
	    AREA OF THE PROCESSOR.  CERTAIN PROCEDURES ARE USED WHEN
	    THE PROGRAM IS USED IN THIS MANNER.  THEY ARE:

	    1.  THE DIAGNOSTIC MONITOR TRANSFERS CONTROL TO THE PRO-
		GRAM AND STARTS IT AT LOCATION 30002.

	    2.  MONCTL - LOCATION 30043 IS USED AS THE DIAGNOSTIC MON-
		ITOR CONTROL FLAG WORD.

	B.  USER MODE

	    THE PROGRAM WILL OPERATE IN USER MODE AND AS SUCH PROVIDES
	    ASSURANCE THAT THE PROCESSOR IS PERFORMING ALL FUNCTIONS
	    CORRECTLY.  USER MODE STARTING ADDRESS IS 30000.

	C.  SYSTEM EXERCISER

	    STARTING ADDRESS IS 30003.  NO DATA SWITCHES ARE USED BY
	    THIS PROGRAM.

8.0	MISCELLANEOUS

	NONE

9.0	LISTING

DAKAE.HST

    THIS IS A HISTORY OF THE DEVELOPMENT OF MAINDEC-10-DAKAE

************************************************************************

ORIGINAL VERSION:   0.1

ORIGINAL AUTHOR:    RICHARD MALISKA

ORIGINAL RELEASE:   16-MAR-72

************************************************************************

PRODUCT CODE:       MAINDEC-10-DAKAE

PRODUCT NAME:       BASIC INSTRUCTION DIAGNOSTIC #5

DATE RELEASED:      JANUARY 1977

VERSION:            0.2

UPDATE AUTHOR:      JOHN R. KIRCHOFF

CHANGES MADE:

    1. UPGRADE TO ALLOW COMPATABILITY WITH THE SUBROUTINE PACKAGE.
************************************************************************

PRODUCT CODE:       MAINDEC-10-DAKAE

PRODUCT NAME:       BASIC INSTRUCTION DIAGNOSTIC #5

DATE RELEASED:      JANUARY 1979

VERSION:            0.3

UPDATE AUTHOR:      BILL SCORZELLI

CHANGES MADE:

    1. THE COMPARE INSTRUCTION TESTS DID NOT CHECK THE COMPARE OF 2
    NEGATIVE NUMBERS WITH THE CONTENTS OF THE (AC) BEING LARGER
    THAN THE CONTENTS OF (E). ADDED TEST C52205.

************************************************************************