document generated automatically
Global description: Data model for Horizon Europe FORTESIES project
version: 2.0.0
[*] If there is not a type in an attribute is because it could have several types or different formats/patterns
-
activePower[object]
: Active power consumed per phase. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/StructuredValueL1[number]
: Property. Value for phase 1 of the active powerL2[number]
: Property. Value for phase 2 of the active powerL3[number]
: Property. Value for phase 3 of the active power
-
address[object]
: The mailing address . Model: https://schema.org/addressaddressCountry[string]
: Property. The country. For example, Spain. Model:'https://schema.org/addressCountry'addressLocality[string]
: Property. The locality in which the street address is, and which is in the region. Model:'https://schema.org/addressLocality'addressRegion[string]
: Property. The region in which the locality is, and which is in the country. Model:'https://schema.org/addressRegion'district[string]
: Property. A district is a type of administrative division that, in some countries, is managed by the local governmentpostOfficeBoxNumber[string]
: Property. The post office box number for PO box addresses. For example, 03578. Model:'https://schema.org/postOfficeBoxNumber'postalCode[string]
: Property. The postal code. For example, 24004. Model:'https://schema.org/https://schema.org/postalCode'streetAddress[string]
: Property. The street address. Model:'https://schema.org/streetAddress'streetNr[string]
: Property. Number identifying a specific property on a public street
-
agreedSavings[number]
: Percentage of savings agreed by the contract. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
alternateName[string]
: An alternative name for this item -
apparentPower[object]
: Apparent power consumed per phase. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/StructuredValueL1[number]
: Property. Value for phase 1 of the apparent powerL2[number]
: Property. Value for phase 2 of the apparent powerL3[number]
: Property. Value for phase 3 of the apparent power
-
areaServed[string]
: The geographic area where a service or offered item is provided . Model: https://schema.org/Text -
challengeRewardValue[number]
: The green euros the user won from the challenge (if applicable). . Model: https://schema.org/Number -
co2[number]
: Carbon Dioxide detected -
constantTerm[number]
: Real consumption of energy in the period to be evaluated for the calculation of the EPC. . Model: https://schema.org/Number -
consumerBonusPercentage[number]
: Percentage of the bonus which is given to the Consumer. This percentage can be for the whole contract or different for each year. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
consumerMalusPercentage[number]
: Percentage of the malus which is given to the Consumer. This percentage can be for the whole contract or different for each year. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
contactStatus[boolean]
: The contact indication, true = broken (open), false = in place (closed) -
coolingDegreeDays[number]
: Cooling degree days are calculated based on the number of degrees that the average outdoor temperature rises above a specified baseline temperature over a given period of a day. . Model: https://schema.org/Number -
current[object]
: Electrical current. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/StructuredValueL1[number]
: Property. Value for phase 1 of the currentL2[number]
: Property. Value for phase 2 of the currentL3[number]
: Property. Value for phase 3 of the currentN[number]
: Property. Value for phase neutral of the current
-
dataProvider[string]
: A sequence of characters identifying the provider of the harmonised data entity -
dateCreated[date-time]
: Entity creation timestamp. This will usually be allocated by the storage platform -
dateModified[date-time]
: Timestamp of the last modification of the entity. This will usually be allocated by the storage platform -
description[string]
: A description of this item -
energyPrice[number]
: Energy price for each month, needed for the calculation of the savings and billed price. . Model: https://schema.org/Number -
escoBonusPercentage[number]
: Percentage of the bonus which is given to the ESCO. This percentage can be for the whole contract or different for each year. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
escoMalusPercentage[number]
: Percentage of the malus which is given to the ESCO. This percentage can be for the whole contract or different for each year. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
excludedConsumption[number]
: Consumptions that are excluded from the EPC due to various reasons. For example sanitary water consumption is excluded from savings calculations in most EPCs because renovations doesn’t affect them. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
excludedSavings[number]
: Savings that are excluded from the EPC due to various reasons. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
fixedPrice[number]
: Fixed price of the contract charged to the consumer each month. . Model: https://schema.org/Number -
frequency[number]
: The frequency of the circuit. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
gasConsumption[number]
: Gas consumed. The unit code (text) is given using the UN/CEFACT Common Codes.' . Model: https://schema.org/Number -
greenEuroBalance[number]
: . Model: https://schema.org/Number. -
heatingDegreeDays[number]
: . Model: [https://schema.org/Number.Heating degree days are calculated based on the number of degrees that the average outdoor temperature falls below a specified baseline temperature over a given period of a day](https://schema.org/Number.Heating degree days are calculated based on the number of degrees that the average outdoor temperature falls below a specified baseline temperature over a given period of a day) -
id[*]
: Unique identifier of the entity -
illuminance[number]
: . Model: https://schema.org/Number -
location[*]
: GeoProperty. Geojson reference to the item. It can be Point, LineString, Polygon, MultiPoint, MultiLineString or MultiPolygon -
name[string]
: The name of this item -
nominalReturnWaterTemperatureHeating[number]
: Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement -
nominalSupplyWaterTemperatureHeating[number]
: Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement -
nominalWaterFlowCooling[number]
: Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement -
nominalWaterFlowHeating[number]
: Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement -
owner[array]
: A List containing a JSON encoded sequence of characters referencing the unique Ids of the owner(s) -
phaseToPhaseVoltage[object]
: Voltage between phases. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/StructuredValueL12[number]
: Property. Value for phase 1 to phase 2 voltageL23[number]
: Property. Value for phase 2 to phase 3 voltageL31[number]
: Property. Value for phase 3 to phase 1 voltage
-
phaseVoltage[object]
: The voltage between each phase and neutral conductor. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/StructuredValueL1[number]
: Property. Value for phase 1 of the voltageL2[number]
: Property. Value for phase 2 of the voltageL3[number]
: Property. Value for phase 3 of the voltage
-
pm25[number]
: Particulate matter 2.5 micrometers or less in diameter -
volatileOrganicCompoundsTotal[number]
: Alkanes <C10, ketones <C6, aldehydes <C10, carboxylic acids <C5, aspirits<C7, Alkenes <C8, Aromatics -
powerFactor[object]
: Power factor for each phase . Model: https://schema.org/StructuredValueL1[number]
: Property. Value for phase 1 of the power factorL2[number]
: Property. Value for phase 2 of the power factorL3[number]
: Property. Value for phase 3 of the power factor
-
precipitation[number]
: Amount of water rain registered . Model: https://schema.org/Number -
reactivePower[object]
: Fundamental frequency reactive power. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/StructuredValueL1[number]
: Property. Value for phase 1 of the reactive powerL2[number]
: Property. Value for phase 2 of the reactive powerL3[number]
: Property. Value for phase 3 of the reactive power
-
recommendationEngineChallengeStatus[string]
: The status of the challenge WON, FAILED . Model: https://schema.org/TEXT -
recommendationEngineMessageAppartmentId[string]
: Check Google sheet fortesie-demo-endpoint. . Model: [https://schema.org/TEXT.Apartment ID for the specific apartment](https://schema.org/TEXT.Apartment ID for the specific apartment) -
recommendationEngineMessageCorrectResponse[string]
: Correct answer for a recommendationEngineMessageResponse entity. . Model: https://schema.org/TEXT -
recommendationEngineMessageId[string]
: The unique id of the recommendation for reference. . Model: https://schema.org/StructuredValue -
recommendationEngineMessagePeriod[string]
: Period of time the challenge is covering (note. same challenge cannot be realised twice within the same period). . Model: https://schema.org/StructuredValue -
recommendationEngineMessageResponse[string]
: Question or other response text that require user input. . Model: https://schema.org/TEXT -
recommendationEngineMessageText[string]
: recommendation_message . Model: https://schema.org/TEXT -
recommendationEngineMessageTimeToShow[date]
: The time in ISO 8601 UTC mobile app will show the recommendation_engine_message_text entity . Model: https://schema.org/Number -
recommendationEngineMessageType[string]
: . Model: [https://schema.org/StructuredValue.Recommendation type](https://schema.org/StructuredValue.Recommendation type) -
referenceCoolingDegreeDays[number]
: Reference heating degree days are calculated based on the number of degrees that the average outdoor temperature falls below a specified baseline temperature over a given period of a day used for the definition of the contact ESCO and customer. . Model: https://schema.org/Number -
referenceElectricalConsumption[number]
: Reference electrical energy consumption used for the calculation of the baseline consumption. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
referenceHeatingDegreeDays[number]
: . Model: [https://schema.org/Number.Reference heating degree days are calculated based on the number of degrees that the average outdoor temperature falls below a specified baseline temperature over a given period of a day used for the definition of the contact ESCO and customer.](https://schema.org/Number.Reference heating degree days are calculated based on the number of degrees that the average outdoor temperature falls below a specified baseline temperature over a given period of a day used for the definition of the contact ESCO and customer.) -
referenceThermalConsumption[number]
: The unit code (text) is given using the UN/CEFACT Common Codes . Model: [https://schema.org/Number.Reference thermal energy consumption used for the calculation of the baseline consumption](https://schema.org/Number.Reference thermal energy consumption used for the calculation of the baseline consumption) -
relativeHumidity[number]
: Relative Humidity of the air (a number between 0 and 1 representing the range of 0% to 100%) -
seeAlso[*]
: list of uri pointing to additional resources about the item -
source[string]
: A sequence of characters giving the original source of the entity data as a URL. Recommended to be the fully qualified domain name of the source provider, or the URL to the source object -
temperature[number]
: Temperature of the item -
thermalEnergyExport[number]
: Thermal energy exported i.e. generated. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
thermalEnergyImport[number]
: Thermal energy imported i.e. consumed. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
thresholdSavings[number]
: Percentage of savings that determines the interval in which the EPC bonus or malus is applied. For example a +-5% range, in which neither a bonus or malus is applied. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalActiveEnergyExport[number]
: Total energy imported i.e. consumed . The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalActiveEnergyImport[number]
: Total energy imported i.e. consumed. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalActivePowerExport[number]
: Total Active Power consumed. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalActivePowerImport[number]
: Total Active Power generated. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalApparentEnergyExport[number]
: Total energy exported (with regards to apparent power). The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/StructuredValue -
totalApparentEnergyImport[number]
: Total energy imported i.e. consumed (with regards to apparent power). The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalApparentPowerExport[number]
: Total Apparent Power consumed. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalApparentPowerImport[number]
: Total Apparent Power generated. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalReactiveEnergyExport[number]
: Total fundamental frequency reactive energy exported. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/StructuredValue -
totalReactiveEnergyImport[number]
: Total energy imported i.e. consumed (with regards to fundamental frequency reactive power). The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalReactivePowerExport[number]
: Total Reactive Power consumed. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
totalReactivePowerImport[number]
: Total Reactive Power generated. The unit code (text) is given using the UN/CEFACT Common Codes . Model: https://schema.org/Number -
type[string]
: NGSI Entity type. It has to be fortesie -
userEmail[string]
: The email of the user of the mobile & green euro apps. . Model: https://schema.org/StructuredValue -
variableTerm[number]
: Variable term of the equation (varaibleTerm*X+constantTerm) for the calculation of the baseline consumption. . Model: https://schema.org/Number -
verifiedEnergySavings[number]
: output of the M&V components after the correction with the dependent variables (ie temperature) . Model: https://schema.org/Number -
windDirection[number]
: Direction of the wind bet . Model: http://schema.org/Number -
windSpeed[number]
: Intensity of the wind . Model: http//schema.org/Number
Required properties
id
type
Sorted alphabetically (click for details)
full yaml details
fortesie_data_model:
description: Data model for Horizon Europe FORTESIES project
properties:
activePower:
description: Active power consumed per phase. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
properties:
L1:
description: Property. Value for phase 1 of the active power
minimum: 0
type: number
L2:
description: Property. Value for phase 2 of the active power
minimum: 0
type: number
L3:
description: Property. Value for phase 3 of the active power
minimum: 0
type: number
type: object
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
units: Watt
address:
description: The mailing address
properties:
addressCountry:
description: Property. The country. For example, Spain. Model:'https://schema.org/addressCountry'
type: string
addressLocality:
description: Property. The locality in which the street address is, and which is in the region. Model:'https://schema.org/addressLocality'
type: string
addressRegion:
description: Property. The region in which the locality is, and which is in the country. Model:'https://schema.org/addressRegion'
type: string
district:
description: Property. A district is a type of administrative division that, in some countries, is managed by the local government
type: string
postOfficeBoxNumber:
description: Property. The post office box number for PO box addresses. For example, 03578. Model:'https://schema.org/postOfficeBoxNumber'
type: string
postalCode:
description: Property. The postal code. For example, 24004. Model:'https://schema.org/https://schema.org/postalCode'
type: string
streetAddress:
description: Property. The street address. Model:'https://schema.org/streetAddress'
type: string
streetNr:
description: Property. Number identifying a specific property on a public street
type: string
type: object
x-ngsi:
model: https://schema.org/address
type: Property
agreedSavings:
description: Percentage of savings agreed by the contract. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: '%'
alternateName:
description: An alternative name for this item
type: string
x-ngsi:
type: Property
apparentPower:
description: Apparent power consumed per phase. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
properties:
L1:
description: Property. Value for phase 1 of the apparent power
minimum: 0
type: number
L2:
description: Property. Value for phase 2 of the apparent power
minimum: 0
type: number
L3:
description: Property. Value for phase 3 of the apparent power
minimum: 0
type: number
type: object
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
units: Watt
areaServed:
description: The geographic area where a service or offered item is provided
type: string
x-ngsi:
model: https://schema.org/Text
type: Property
challengeRewardValue:
description: The green euros the user won from the challenge (if applicable).
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
co2:
description: Carbon Dioxide detected
minimum: 0
type: number
x-ngsi:
type: Property
constantTerm:
description: 'Real consumption of energy in the period to be evaluated for the calculation of the EPC. '
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
consumerBonusPercentage:
description: Percentage of the bonus which is given to the Consumer. This percentage can be for the whole contract or different for each year. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: '%'
consumerMalusPercentage:
description: Percentage of the malus which is given to the Consumer. This percentage can be for the whole contract or different for each year. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: '%'
contactStatus:
description: The contact indication, true = broken (open), false = in place (closed)
readOnly: yes
type: boolean
x-ngsi:
type: Property
coolingDegreeDays:
description: Cooling degree days are calculated based on the number of degrees that the average outdoor temperature rises above a specified baseline temperature over a given period of a day.
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
current:
description: Electrical current. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
properties:
L1:
description: Property. Value for phase 1 of the current
type: number
L2:
description: Property. Value for phase 2 of the current
type: number
L3:
description: Property. Value for phase 3 of the current
type: number
N:
description: Property. Value for phase neutral of the current
type: number
type: object
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
units: Ampere
dataProvider:
description: A sequence of characters identifying the provider of the harmonised data entity
type: string
x-ngsi:
type: Property
dateCreated:
description: Entity creation timestamp. This will usually be allocated by the storage platform
format: date-time
type: string
x-ngsi:
type: Property
dateModified:
description: Timestamp of the last modification of the entity. This will usually be allocated by the storage platform
format: date-time
type: string
x-ngsi:
type: Property
description:
description: A description of this item
type: string
x-ngsi:
type: Property
energyPrice:
description: Energy price for each month, needed for the calculation of the savings and billed price.
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
escoBonusPercentage:
description: Percentage of the bonus which is given to the ESCO. This percentage can be for the whole contract or different for each year. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: '%'
escoMalusPercentage:
description: Percentage of the malus which is given to the ESCO. This percentage can be for the whole contract or different for each year. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: '%'
excludedConsumption:
description: Consumptions that are excluded from the EPC due to various reasons. For example sanitary water consumption is excluded from savings calculations in most EPCs because renovations doesn’t affect them. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: kilovolt-ampere-hour
excludedSavings:
description: Savings that are excluded from the EPC due to various reasons. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: kilovolt-ampere-hour
fixedPrice:
description: Fixed price of the contract charged to the consumer each month.
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
frequency:
description: The frequency of the circuit. The unit code (text) is given using the [UN/CEFACT Common Codes](http://wiki.goodrelations-vocabulary.org/Documentation/UN/CEFACT_Common_Codes)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: Hertz
gasConsumption:
description: Gas consumed. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20).'
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
greenEuroBalance:
description: ''
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number.
type: Property
heatingDegreeDays:
description: ''
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number.Heating degree days are calculated based on the number of degrees that the average outdoor temperature falls below a specified baseline temperature over a given period of a day
type: Property
id:
anyOf:
- description: Property. Identifier format of any NGSI entity
maxLength: 256
minLength: 1
pattern: ^[\w\-\.\{\}\$\+\*\[\]`|~^@!,:\\]+$
type: string
- description: Property. Identifier format of any NGSI entity
format: uri
type: string
description: Unique identifier of the entity
x-ngsi:
type: Relationship
illuminance:
description: ''
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: Measured illuminance LUX.
location:
description: GeoProperty. Geojson reference to the item. It can be Point, LineString, Polygon, MultiPoint, MultiLineString or MultiPolygon
oneOf:
- description: GeoProperty. Geojson reference to the item. Point
properties:
bbox:
items:
type: number
minItems: 4
type: array
coordinates:
items:
type: number
minItems: 2
type: array
type:
enum:
- Point
type: string
required:
- type
- coordinates
title: GeoJSON Point
type: object
- description: GeoProperty. Geojson reference to the item. LineString
properties:
bbox:
items:
type: number
minItems: 4
type: array
coordinates:
items:
items:
type: number
minItems: 2
type: array
minItems: 2
type: array
type:
enum:
- LineString
type: string
required:
- type
- coordinates
title: GeoJSON LineString
type: object
- description: GeoProperty. Geojson reference to the item. Polygon
properties:
bbox:
items:
type: number
minItems: 4
type: array
coordinates:
items:
items:
items:
type: number
minItems: 2
type: array
minItems: 4
type: array
type: array
type:
enum:
- Polygon
type: string
required:
- type
- coordinates
title: GeoJSON Polygon
type: object
- description: GeoProperty. Geojson reference to the item. MultiPoint
properties:
bbox:
items:
type: number
minItems: 4
type: array
coordinates:
items:
items:
type: number
minItems: 2
type: array
type: array
type:
enum:
- MultiPoint
type: string
required:
- type
- coordinates
title: GeoJSON MultiPoint
type: object
- description: GeoProperty. Geojson reference to the item. MultiLineString
properties:
bbox:
items:
type: number
minItems: 4
type: array
coordinates:
items:
items:
items:
type: number
minItems: 2
type: array
minItems: 2
type: array
type: array
type:
enum:
- MultiLineString
type: string
required:
- type
- coordinates
title: GeoJSON MultiLineString
type: object
- description: GeoProperty. Geojson reference to the item. MultiLineString
properties:
bbox:
items:
type: number
minItems: 4
type: array
coordinates:
items:
items:
items:
items:
type: number
minItems: 2
type: array
minItems: 4
type: array
type: array
type: array
type:
enum:
- MultiPolygon
type: string
required:
- type
- coordinates
title: GeoJSON MultiPolygon
type: object
name:
description: The name of this item
type: string
x-ngsi:
type: Property
nominalReturnWaterTemperatureHeating:
description: Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement
type: number
x-ngsi:
type: Property
nominalSupplyWaterTemperatureHeating:
description: Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement
type: number
x-ngsi:
type: Property
nominalWaterFlowCooling:
description: Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement
type: number
x-ngsi:
type: Property
nominalWaterFlowHeating:
description: Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement
type: number
x-ngsi:
type: Property
owner:
description: A List containing a JSON encoded sequence of characters referencing the unique Ids of the owner(s)
items:
anyOf:
- description: Property. Identifier format of any NGSI entity
maxLength: 256
minLength: 1
pattern: ^[\w\-\.\{\}\$\+\*\[\]`|~^@!,:\\]+$
type: string
- description: Property. Identifier format of any NGSI entity
format: uri
type: string
description: Relationship. Unique identifier of the entity
type: array
x-ngsi:
type: Property
phaseToPhaseVoltage:
description: Voltage between phases. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
properties:
L12:
description: Property. Value for phase 1 to phase 2 voltage
minimum: 0
type: number
L23:
description: Property. Value for phase 2 to phase 3 voltage
minimum: 0
type: number
L31:
description: Property. Value for phase 3 to phase 1 voltage
minimum: 0
type: number
type: object
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
units: Volts
phaseVoltage:
description: The voltage between each phase and neutral conductor. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
properties:
L1:
description: Property. Value for phase 1 of the voltage
minimum: 0
type: number
L2:
description: Property. Value for phase 2 of the voltage
minimum: 0
type: number
L3:
description: Property. Value for phase 3 of the voltage
minimum: 0
type: number
type: object
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
units: Volts
pm25:
description: Particulate matter 2.5 micrometers or less in diameter
minimum: 0
type: number
x-ngsi:
type: Property
powerFactor:
description: Power factor for each phase
properties:
L1:
description: Property. Value for phase 1 of the power factor
maximum: 1
minimum: -1
type: number
L2:
description: Property. Value for phase 2 of the power factor
maximum: 1
minimum: -1
type: number
L3:
description: Property. Value for phase 3 of the power factor
maximum: 1
minimum: -1
type: number
type: object
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
precipitation:
description: Amount of water rain registered
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: Liters per square meter.
reactivePower:
description: Fundamental frequency reactive power. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
properties:
L1:
description: Property. Value for phase 1 of the reactive power
type: number
L2:
description: Property. Value for phase 2 of the reactive power
type: number
L3:
description: Property. Value for phase 3 of the reactive power
type: number
type: object
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
units: volts-ampere-reactive
recommendationEngineChallengeStatus:
description: The status of the challenge WON, FAILED
enum:
- WON
- FAILED
type: string
x-ngsi:
model: https://schema.org/TEXT
type: Property
recommendationEngineMessageAppartmentId:
description: Check Google sheet fortesie-demo-endpoint.
type: string
x-ngsi:
model: https://schema.org/TEXT.Apartment ID for the specific apartment
type: Property
recommendationEngineMessageCorrectResponse:
description: Correct answer for a recommendationEngineMessageResponse entity.
type: string
x-ngsi:
model: https://schema.org/TEXT
type: Property
recommendationEngineMessageId:
description: The unique id of the recommendation for reference.
type: string
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
recommendationEngineMessagePeriod:
description: Period of time the challenge is covering (note. same challenge cannot be realised twice within the same period).
enum:
- DAY
- MONTH
- WEEK
- YEAR
- ALL
type: string
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
recommendationEngineMessageResponse:
description: Question or other response text that require user input.
type: string
x-ngsi:
model: https://schema.org/TEXT
type: Property
recommendationEngineMessageText:
description: recommendation_message
type: string
x-ngsi:
model: https://schema.org/TEXT
type: Property
recommendationEngineMessageTimeToShow:
description: 'The time in ISO 8601 UTC mobile app will show the recommendation_engine_message_text entity '
minimum: 0
type: date
x-ngsi:
model: https://schema.org/Number
type: Property
recommendationEngineMessageType:
description: ''
enum:
- MONTHLY_CHALLENGE
- QUIZ
- ENERGY_SAVING_RECOMMENDATION
- RENOVATION_RECOMMENDATION
- WARNING
type: string
x-ngsi:
model: https://schema.org/StructuredValue.Recommendation type
type: Property
referenceCoolingDegreeDays:
description: Reference heating degree days are calculated based on the number of degrees that the average outdoor temperature falls below a specified baseline temperature over a given period of a day used for the definition of the contact ESCO and customer.
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
referenceElectricalConsumption:
description: Reference electrical energy consumption used for the calculation of the baseline consumption. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: kilovolt-ampere-hour
referenceHeatingDegreeDays:
description: ''
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number.Reference heating degree days are calculated based on the number of degrees that the average outdoor temperature falls below a specified baseline temperature over a given period of a day used for the definition of the contact ESCO and customer.
type: Property
referenceThermalConsumption:
description: The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number.Reference thermal energy consumption used for the calculation of the baseline consumption
type: Property
units: kilovolt-ampere-hour
relativeHumidity:
description: Relative Humidity of the air (a number between 0 and 1 representing the range of 0% to 100%)
maximum: 1
minimum: 0
type: number
x-ngsi:
type: Property
seeAlso:
description: list of uri pointing to additional resources about the item
oneOf:
- items:
format: uri
type: string
minItems: 1
type: array
- format: uri
type: string
x-ngsi:
type: Property
source:
description: A sequence of characters giving the original source of the entity data as a URL. Recommended to be the fully qualified domain name of the source provider, or the URL to the source object
type: string
x-ngsi:
type: Property
temperature:
description: Temperature of the item
type: number
x-ngsi:
type: Property
thermalEnergyExport:
description: Thermal energy exported i.e. generated. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: kilovolt-ampere-hour
thermalEnergyImport:
description: Thermal energy imported i.e. consumed. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: kilovolt-ampere-hour
thresholdSavings:
description: Percentage of savings that determines the interval in which the EPC bonus or malus is applied. For example a +-5% range, in which neither a bonus or malus is applied. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: '%'
totalActiveEnergyExport:
description: Total energy imported i.e. consumed . The unit code (text) is given using the [UN/CEFACT Common Codes](http://wiki.goodrelations-vocabulary.org/Documentation/UN/CEFACT_Common_Codes)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: kilowatt hour
totalActiveEnergyImport:
description: Total energy imported i.e. consumed. The unit code (text) is given using the [UN/CEFACT Common Codes](http://wiki.goodrelations-vocabulary.org/Documentation/UN/CEFACT_Common_Codes)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: kilowatt hour
totalActivePowerExport:
description: Total Active Power consumed. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: Watt
totalActivePowerImport:
description: Total Active Power generated. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: Watt
totalApparentEnergyExport:
description: Total energy exported (with regards to apparent power). The unit code (text) is given using the [UN/CEFACT Common Codes](http://wiki.goodrelations-vocabulary.org/Documentation/UN/CEFACT_Common_Codes)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
units: kilovolt-ampere-hour
totalApparentEnergyImport:
description: Total energy imported i.e. consumed (with regards to apparent power). The unit code (text) is given using the [UN/CEFACT Common Codes](http://wiki.goodrelations-vocabulary.org/Documentation/UN/CEFACT_Common_Codes)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: kilovolt-ampere-hour.
totalApparentPowerExport:
description: Total Apparent Power consumed. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: volt-ampere
totalApparentPowerImport:
description: Total Apparent Power generated. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: volt-ampere
totalReactiveEnergyExport:
description: Total fundamental frequency reactive energy exported. The unit code (text) is given using the [UN/CEFACT Common Codes](http://wiki.goodrelations-vocabulary.org/Documentation/UN/CEFACT_Common_Codes)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
units: kilovolt-ampere-reactive-hour
totalReactiveEnergyImport:
description: Total energy imported i.e. consumed (with regards to fundamental frequency reactive power). The unit code (text) is given using the [UN/CEFACT Common Codes](http://wiki.goodrelations-vocabulary.org/Documentation/UN/CEFACT_Common_Codes)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: kilovolt-ampere-reactive-hour.
totalReactivePowerExport:
description: Total Reactive Power consumed. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: volt-ampere-reactive
totalReactivePowerImport:
description: Total Reactive Power generated. The unit code (text) is given using the [UN/CEFACT Common Codes](https://docs.peppol.eu/poacc/billing/3.0/codelist/UNECERec20)
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
units: volt-ampere-reactive
type:
description: NGSI Entity type. It has to be fortesie
enum:
- fortesie
type: string
x-ngsi:
type: Property
userEmail:
description: The email of the user of the mobile & green euro apps.
type: string
x-ngsi:
model: https://schema.org/StructuredValue
type: Property
variableTerm:
description: Variable term of the equation (varaibleTerm*X+constantTerm) for the calculation of the baseline consumption.
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
verifiedEnergySavings:
description: output of the M&V components after the correction with the dependent variables (ie temperature)
minimum: 0
type: number
x-ngsi:
model: https://schema.org/Number
type: Property
volatileOrganicCompoundsTotal:
description: Alkanes <C10, ketones <C6, aldehydes <C10, carboxylic acids <C5, aspirits<C7, Alkenes <C8, Aromatics
minimum: 0
type: number
x-ngsi:
type: Property
windDirection:
description: Direction of the wind bet
maximum: 360
minimum: 0
type: number
x-ngsi:
model: http://schema.org/Number
type: Property
windSpeed:
description: Intensity of the wind
minimum: 0
type: number
x-ngsi:
model: http//schema.org/Number
type: Property
required:
- id
- type
type: object
x-derived-from: ''
x-disclaimer: Redistribution and use in source and binary forms, with or without modification, are permitted provided that the license conditions are met. Copyleft (c) 2021 Contributors to Smart Data Models Program
x-license-url: https://github.com/smart-data-models/fortesie_data_model/blob/master/fortesie_data_model/LICENSE.md
x-model-schema: https://raw.githubusercontent.com/konstantinosGombakis/fortesie_data_model/main/FORTESIES_data_model/schema.json
x-model-tags: ''
x-version: 2.0.0
Not available the example of a fortesie_data_model in JSON-LD format as key-values. This is compatible with NGSI-LD when using options=keyValues
and returns the context data of an individual entity.
Here is an example of a fortesie_data_model in JSON-LD format as normalized. This is compatible with NGSI-LD when not using options and returns the context data of an individual entity.
show/hide example
{
"id": "urn:ngsi-ld:FORTESIE:DEMO-1:device-id-001",
"type": "fortesie",
"@context": [
"http://forteseie-ld-context/fortesie-context.jsonld"
],
"phaseVoltage": {
"type": "Property",
"value": 223.6,
"unitCode": "2G",
"observedAt": "2023-09-15T16:04:49Z"
},
"phaseToPhaseVoltage": {
"type": "Property",
"value": [
252.2,
223,
224.3
],
"unitCode": "2G",
"observedAt": "2023-09-15T16:04:49Z"
},
"current": {
"type": "Property",
"value": 2.7,
"unitCode": "AMP",
"observedAt": "2023-09-15T16:04:49Z"
},
"totalActivePower": {
"type": "Property",
"value": 344.8,
"unitCode": "K1",
"observedAt": "2023-09-15T16:04:49Z"
},
"totalReactivePower": {
"type": "Property",
"value": 54.7,
"unitCode": "K2",
"observedAt": "2023-09-15T16:04:49Z"
},
"totalApparentPower": {
"type": "Property",
"value": 45.7,
"unitCode": "K1",
"observedAt": "2023-09-15T16:04:49Z"
},
"powerFactor": {
"type": "Property",
"value": 98.2,
"unitCode": "P1",
"observedAt": "2023-09-15T16:04:49Z"
},
"activePower": {
"type": "Property",
"value": 56.2,
"unitCode": "K1",
"observedAt": "2023-09-15T16:04:49Z"
},
"reactivePower": {
"type": "Property",
"value": 32.3,
"unitCode": "K2",
"observedAt": "2023-09-15T16:04:49Z"
},
"apparentPower": {
"type": "Property",
"value": 45.8,
"unitCode": "P1",
"observedAt": "2023-09-15T16:04:49Z"
},
"totalActiveEnergyImport": {
"type": "Property",
"value": 32.2,
"unitCode": "KWH",
"observedAt": "2023-09-15T16:04:49.000Z"
},
"totalActiveEnergyExport": {
"type": "Property",
"value": 1.2,
"unitCode": "KWH",
"observedAt": "2023-09-15T16:04:49.000Z"
},
"totalReactiveEnergyImport": {
"type": "Property",
"value": 6.2,
"unitCode": "KWH",
"observedAt": "2023-09-15T16:04:49.000Z"
},
"totalReactiveEnergyExport": {
"type": "Property",
"value": 1.2,
"unitCode": "KWH",
"observedAt": "2023-09-15T16:04:49.000Z"
},
"totalApparentEnergyImport": {
"type": "Property",
"value": 34.2,
"unitCode": "KWH",
"observedAt": "2023-09-15T16:04:49Z"
},
"totalApparentEnergyExport": {
"type": "Property",
"value": 4.2,
"unitCode": "KWH",
"observedAt": "2023-09-15T16:04:49Z"
},
"frequency": {
"type": "Property",
"value": 658.2,
"unitCode": "HTZ",
"observedAt": "2023-09-15T16:04:49Z"
},
"nominalWaterFlowHeating": {
"type": "Property",
"value": 54.1,
"unitCode": "MQS",
"observedAt": "2023-09-15T16:04:49Z"
},
"thermalEnergyImport": {
"type": "Property",
"value": 619.8,
"unitCode": "3B",
"observedAt": "2023-09-15T16:04:49Z"
},
"thermalEnergyExport": {
"type": "Property",
"value": 553.8,
"unitCode": "3B",
"observedAt": "2023-09-15T16:04:49Z"
},
"nominalSupplyWaterTemperatureHeating": {
"type": "Property",
"value": 23.8,
"unitCode": "CEL",
"observedAt": "2023-09-15T16:04:49Z"
},
"nominalWaterFlowCooling": {
"type": "Property",
"value": 936.1,
"unitCode": "MQS",
"observedAt": "2023-09-15T16:04:49Z"
},
"nominalReturnWaterTemeratureHeating": {
"type": "Propertyp",
"value": 10.3,
"unitCode": "CEL",
"observedAt": "2023-09-15T16:04:49Z"
},
"gasConsumption": {
"type": "Property",
"value": 727.0,
"unitCode": "3B",
"observedAt": "2023-09-15T16:04:49Z"
},
"temperature": {
"type": "Property",
"value": 18.4,
"unitCode": "CEL",
"observedAt": "2023-09-15T16:04:49Z"
},
"relativeHumidity": {
"type": "Property",
"value": 39.0,
"unitCode": "P1",
"observedAt": "2023-09-15T16:04:49Z"
},
"pm25": {
"type": "Property",
"value": 36.0,
"unitCode": "GQ",
"observedAt": "2023-09-15T16:04:49Z"
},
"co2": {
"type": "Property",
"value": 690.5,
"unitCode": "59",
"observedAt": "2023-09-15T16:04:49Z"
},
"windSpeed": {
"type": "Property",
"value": 2.5,
"unitCode": "KMH",
"observedAt": "2023-09-15T16:04:49Z"
},
"windDirection": {
"type": "Property",
"value": 231,
"unitCode": "DD",
"observedAt": "2023-09-15T16:04:49Z"
},
"precipitation": {
"type": "Property",
"value": 34,
"unitCode": "MMT",
"observedAt": "2023-09-15T16:04:49Z"
},
"contactStatus": {
"type": "Property",
"value": true
},
"illuminance": {
"type": "Property",
"value": 194.9,
"unitCode": "KLX",
"observedAt": "2023-09-15T16:04:49Z"
},
"heatingDegreeDays": {
"type": "Property",
"value": 676.9,
"unitCode": "CEL",
"observedAt": "2023-09-15T16:04:49Z"
},
"coolingDegreeDays": {
"type": "Property",
"value": 904.6,
"unitCode": "CEL",
"observedAt": "2023-09-15T16:04:49Z"
},
"referenceHeatingDegreeDays": {
"type": "Property",
"value": 340.5,
"unitCode": "CEL",
"observedAt": "2023-09-15T16:04:49Z"
},
"referenceCoolingDegreeDays": {
"type": "Property",
"value": 359.5,
"unitCode": "CEL",
"observedAt": "2023-09-15T16:04:49Z"
},
"referenceElectricalConsumption": {
"type": "Property",
"value": 282.1,
"unitCode": "KWH",
"observedAt": "2023-09-15T16:04:49Z"
},
"referenceThermalConsumption": {
"type": "Property",
"value": 651.4,
"unitCode": "3B",
"observedAt": "2023-09-15T16:04:49Z"
},
"variableTerm": {
"type": "Property",
"value": 974.6,
"observedAt": "2023-09-15T16:04:49Z"
},
"constantTerm": {
"type": "Property",
"value": 887.1,
"observedAt": "2023-09-15T16:04:49Z"
},
"excludedConsumption": {
"type": "Property",
"value": 896.8,
"unitCode": "KWH",
"observedAt": "2023-09-15T16:04:49Z"
},
"excludedSavings": {
"type": "Property",
"value": 116.6,
"observedAt": "2023-09-15T16:04:49Z"
},
"agreedSavings": {
"type": "Property",
"value": 407.5,
"observedAt": "2023-09-15T16:04:49Z"
},
"thresholdSavings": {
"type": "Property",
"value": 886.6,
"observedAt": "2023-09-15T16:04:49Z"
},
"escoBonusPercentage": {
"type": "Property",
"value": 477.8,
"observedAt": "2023-09-15T16:04:49Z"
},
"consumerBonusPercentage": {
"type": "Property",
"value": 241.0,
"observedAt": "2023-09-15T16:04:49Z"
},
"escoMalusPercentage": {
"type": "Property",
"value": 573.2,
"observedAt": "2023-09-15T16:04:49Z"
},
"consumerMalusPercentage": {
"type": "Property",
"value": 245.9,
"observedAt": "2023-09-15T16:04:49Z"
},
"fixedPrice": {
"type": "Property",
"value": 337.2,
"observedAt": "2023-09-15T16:04:49Z"
},
"energyPrice": {
"type": "Property",
"value": 116.4,
"observedAt": "2023-09-15T16:04:49Z"
},
"verifiedEnergySavings": {
"type": "Property",
"value": 34.6,
"observedAt": "2023-09-15T16:04:49Z"
},
"greenEuroBalance": {
"type": "Property",
"value": 343.6,
"observedAt": "2023-09-15T16:04:49Z",
"unitCode": "€G"
},
"userEmail": {
"type": "Property",
"value": "[email protected]",
"observedAt": "2023-09-15T16:04:49Z"
},
"recommendationEngineMessageId": {
"type": "Property",
"value": "adfd2123123t0",
"observedAt": "2023-09-15T16:04:49Z"
},
"recommendationEngineMessageType": {
"type": "Property",
"value": "WARNING",
"observedAt": "2023-09-15T16:04:49Z"
},
"recommendationEngineMessageText": {
"type": "Property",
"value": "Writer nor type throughout analysis. Every rest between personal bit.",
"observedAt": "2023-09-15T16:04:49Z"
},
"recommendationEngineMessageResponse": {
"type": "Property",
"value": {
"1": "To ensure proper functioning of electronic devices",
"2": "To prevent discomfort due to extreme temperatures",
"3": "To adjust indoor activities accordingly for comfort and health"
},
"observedAt": "2023-09-15T16:04:49Z"
},
"recommendationEngineMessageCorrectResponse": {
"type": "Property",
"value": "3",
"observedAt": "2023-09-15T16:04:49Z"
},
"recommendationEngineMessageTimeToShow": {
"type": "Property",
"value": "2023-09-15T16:04:49Z",
"observedAt": "2023-09-15T16:04:49Z"
},
"recommendationEngineChallengeStatus": {
"type": "Property",
"value": "WON",
"observedAt": "2023-09-15T16:04:49Z"
},
"recommendationEngineMessagePeriod": {
"type": "Property",
"value": "MONTH",
"observedAt": "2023-09-15T16:04:49Z"
},
"recommendationEngineMessageAppartmentId": {
"type": "Property",
"value": "urn:ngsi-ld:fortesie:demo-4:building_286:room_bn2",
"observedAt": "2023-09-15T16:04:49Z"
},
"challengeRewardValue": {
"type": "Property",
"value": 4,
"observedAt": "2023-09-15T16:04:49Z",
"unitCode": "€G"
}
}