Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathsage_boiler.py
615 lines (497 loc) · 20.4 KB
/
sage_boiler.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
import struct
import operator
from unicodedata import normalize
from functools import partial
# Uniform Modbus TCP and RTU interface library
from modbus_tk.modbus_rtu import RtuMaster
from modbus_tk.modbus_tcp import TcpMaster
import modbus_tk.defines as cst
# Used to pretty-print data tables (e.g. stdout)
from tabulate import tabulate
# Cache Modbus register values received for a few seconds, which makes for more
# consistent results in complicated scenarios and also avoids waiting for the
# slow serial interface
from cachetools import cachedmethod, TTLCache
# Full fat API for accessing statistics on Burnham/US Boiler Alpine boiler
# using modbus_tk (supports both Modbus/TCP and Modbus/RTU)
#
# Developed and tested to work with my ALP105BW-4T02
#
# References and other work
# * Simpler, minimalmodbus-based: https://github.com/alanmitchell/mini-monitor/blob/master/readers/sage_boiler.py
# * Sage2 Controller Modbus Interface Documentation (circa 2012): https://www.ccontrols.com/support/dp/Sage2.doc
class Sage2Reading(object):
multiplier, offset = 1, 0
default_format = '{self.title}: {self.value:d}'
units = None
def __init__(self, boiler, register, title, units=None, summary=False):
self.boiler = boiler
self.register = register
self.title = title
self.summary = summary
if units:
self.units = units
def __format__(self, fmt=None):
fmt = fmt or self.default_format
return fmt.format(self=self)
#def __unicode__(self):
# return format(self)
def __str__(self):
return normalize('NFKD', format(self)).encode('ascii', 'ignore')
@property
def value(self):
value = self.raw_value * self.multiplier + self.offset
return int(value) == value and int(value) or round(value, 1)
@property
def raw_value(self):
return self.boiler.read(self.register, 1)
class Sage2FiringRateReading(Sage2Reading):
units = '%'
@property
def value(self):
"Returns firing rate as a percentage, expressed as a integer 0-100"
raw_value = self.raw_value
value = raw_value & (2**15 - 1) # strip most significant bit
modulation_source = self.boiler.read(192, 1)
if (raw_value >> 15 == modulation_source):
if modulation_source == 0: # RPM
max_rpm = self.boiler.read(193, 1)
min_rpm = self.boiler.read(195, 1)
value = 100.0 * value / (max_rpm)
elif modulation_source == 1: # 0-10V
value = value / 10.0
else:
value = 0
return int(value)
class Sage2TemperatureReading(Sage2Reading):
multiplier, offset = 0.18, 32 # Fahrenheit
#multiplier, offset = 0.1, 0 # Celsius
default_format = u'{self.title}: {self.value:.1f}'
units = u'\N{DEGREE SIGN}F'
@property
def raw_value(self):
temperature = super(Sage2TemperatureReading, self).raw_value
# Docs say these are unsigned 16-bit integers, but temperatures appear
# to be signed, as described at:
#
# http://github.com/alanmitchell/mini-monitor/blob/master/readers/sage_boiler.py
return temperature if temperature < 2**15 else temperature - 2**16
class Sage2FlameSignalReading(Sage2Reading):
multiplier = 0.01
units = u'\N{MICRO SIGN}A'
class Sage2ModulationReading(Sage2Reading):
@property
def raw_value(self):
modulation = super(Sage2ModulationReading, self).raw_value
if modulation < 2**15:
self.units = 'rpm'
else:
self.units = '%'
self.offset = -2**15
return modulation
class Sage2EnumeratedReading(Sage2Reading):
default_format = '{self.title}: {self.value}'
possible_values = {}
@property
def raw_value(self):
from functools import reduce
"Returns largest matching key within enumeration of possible values"
raw_value = super(Sage2EnumeratedReading, self).raw_value
largest_match = lambda x, y: y <= raw_value and y or x
return reduce(largest_match, sorted(self.possible_values))
@property
def value(self):
"Returns largest matching value from enumeration of possible values"
return self.possible_values.get(self.raw_value, None)
class Sage2BurnerStateReading(Sage2EnumeratedReading):
possible_values = {
0: 'Initiate',
1: 'Standby Delay',
2: 'Standby',
3: 'Safe Startup',
4: 'Prepurge - Drive to Purge Rate',
5: 'Prepurge - Measured Purge Time',
6: 'Prepurge - Drive to Lightoff Rate',
7: 'Preigition Test',
8: 'Preigition Time',
9: 'Pilot Flame Establishing Period',
10: 'Main Flame Establishing Period',
11: 'Direct Burner Ignition',
12: 'Run',
13: 'Postpurge',
14: 'Lockout',
255: 'Safety Processor Offline'
}
class Sage2SensorStateReading(Sage2EnumeratedReading):
possible_values = {
0: 'None',
1: 'Normal',
2: 'Open',
3: 'Shorted',
4: 'Above High Range',
5: 'Below Low Range',
6: 'Not Reliable'
}
class Sage2ModulationStateReading(Sage2EnumeratedReading):
possible_values = {
0: 'No Active Sensor',
1: 'DHW Sensor (S6S7)',
2: 'Outlet Sensor (S3S4)',
3: 'Inlet Sensor (S1)',
4: '4-20mA Input (S2)',
5: 'Header Sensor (S5)', # 'S5 Sensor' in Sage2 docs
6: 'S10 Sensor (S10)',
7: 'Steam Sensor (S1)'
}
class Sage2SetpointSourceReading(Sage2EnumeratedReading):
possible_values = {
0: 'Unknown',
1: 'CH Setpoint',
2: 'CH Time of Day Setpoint',
3: 'Outdoor Reset Setpoint',
4: 'Remote Control Setpoint',
5: 'DHW Tap Setpoint',
6: 'DHW Preheat Setpoint',
7: 'Outdoor Reset Time of Day Setpoint',
8: 'Mix Setpoint'
}
class Sage2DemandReading(Sage2EnumeratedReading):
possible_values = {
0: 'Off',
1: 'On'
}
class Sage2PumpStatusReading(Sage2EnumeratedReading):
# Tables in Sage2 documentation are numbered 7 and 8
possible_values = {
92: 'Forced On, from manual pump control',
93: 'Forced On, due to Outlet high limit is active',
94: 'Forced On, from burner demand',
95: 'Forced On, due to Lead Lag slave has demand',
96: 'Forced Off, from local DHW priority service',
97: 'Forced Off, from Lead Lag DHW priority service',
98: 'Forced Off, from Central Heat anti-condensation',
99: 'Forced Off, from DHW anti-condensation',
100: 'Forced Off, due to DHW high limit is active',
101: 'Forced Off, from EnviraCOM DHW priority service',
102: 'On, due to local CH frost protection is active',
103: 'On, due to Lead Lag CH frost protection is active',
104: 'On, due to local DHW frost protection is active',
105: 'On, due to Lead Lag DHW frost protection is active',
106: 'On, from local Central Heat demand',
107: 'On, from Lead Lag Central Heat demand',
108: 'On, from local DHW demand',
109: 'On, from Lead Lag DHW demand',
110: 'On, from local Mix demand',
111: 'On, from Lead Lag Mix demand',
112: 'On, from local Central Heat service',
113: 'On, from Lead Lag Central Heat service',
114: 'On, from local DHW service',
115: 'On, from Lead Lag DHW service',
116: 'On, from local Mix service',
117: 'On, from Lead Lag Mix service',
118: 'On, from Lead Lag auxiliary pump X',
119: 'On, from Lead Lag auxiliary pump Y',
120: 'On, from Lead Lag auxiliary pump Z',
121: 'On, but inhibited by pump start delay',
122: 'On, from pump override',
123: 'Off, not needed',
124: 'On, from burner demand',
125: 'On, from exercise',
126: 'On, from local Lead Lag service',
127: 'On, from local Lead Lag pump demand',
}
class Sage2CounterReading(Sage2Reading):
@property
def raw_value(self):
reg = self.boiler.read(self.register, 2)
#return reg[0] * 2**8 + reg[1] # unsigned 32-bit result
return reg
class Sage2Boiler(object):
def __init__(self, slave=1, host='localhost', port=502, serial=None):
self.cache = TTLCache(maxsize=128, ttl=10)
self.__slave = slave
self.boiler = slave
if serial:
self.__master = RtuMaster(serial, t0=0.01)
else:
self.__master = TcpMaster(host, port)
#self.__master.set_verbose(True)
def tabulate(self, summary=True):
import inspect
def is_reading(prop):
""""Returns True when prop is a property and value of the property
is a Sage2Reading"""
return isinstance(prop, property) \
and isinstance(prop.__get__(self), Sage2Reading)
def readings():
for prop, reading in inspect.getmembers(self.__class__, is_reading):
# Hack below invokes the property object so the descriptor
# calls its wrapped get method, (hopefully) returning a
# Sage2Reading object)
#
# https://docs.python.org/2/howto/descriptor.html
reading = reading.__get__(self)
if summary and not reading.summary:
continue
yield (reading.title, reading.raw_value, reading.value, reading.units,)
#yield (reading.title, reading.value, reading.units,)
return tabulate(readings(), headers=['Reading', 'Raw', 'Value', 'Units'])
#def __unicode__(self):
# return self.tabulate()
def __str__(self):
return normalize('NFKD', self.tabulate()) #.encode('ascii', 'ignore')
def read(self, register, count=1):
assert count <= 2 and count > 0
#reg = self.__master.execute(
# self.__slave, cst.READ_HOLDING_REGISTERS, register, count)
reg = self.dump()[register:register+count]
# Pad 16-bit values with a zero byte
if len(reg) == 1:
reg = (0, reg[0],)
return struct.unpack('>I', struct.pack('>HH', *reg))[0]
@cachedmethod(operator.attrgetter('cache'))
def dump(self):
"""Dump all register values in large batches
Extracting all interesting register values in bulk is up to 12.8x
faster than accessing each register individually, depending on the
number registers accessed.
Returns a tuple of 194 contiguous registers (0-193)
"""
function_code = cst.READ_HOLDING_REGISTERS # aka "3"
get = partial(self.__master.execute, *[self.__slave, function_code])
# Hardcoded register extract for registers 0-177 and 192-209
#
# N.B. Up to 125 registers that can be retrieved in a single request
return get(0, 100) + get(100, 77) + (None,) * 15 + get(192, 36)
def identify_valid_registers(self, min, max):
from operator import itemgetter
from itertools import groupby
def register_walk():
for id in xrange(min, max):
try:
self.__master.execute(self.__slave, cst.READ_HOLDING_REGISTERS, id, 1)
except:
continue
yield id
# clever recipe: https://docs.python.org/2.6/library/itertools.html#examples
ranges = []
data = register_walk()
#for k, g in groupby(enumerate(data), lambda (i,x): i-x):
# group = map(itemgetter(1), g)
# ranges.append((group[0], group[-1],))
#return ranges
# Results for scanning registers 0-10000 on my ALP105 boiler
# [(0, 182), (188, 1122), (1126, 1128), (1132, 1134), (1138, 1140),
# (1144, 1146), (1150, 1152), (1156, 1158), (1162, 1164), (1168, 1170),
# (1174, 1176), (1180, 1182), (1186, 1188), (1192, 1194), (1198, 1200),
# (1204, 1206), (1210, 1344), (1355, 1369), (2048, 2071), (4096, 4108),
# (4110, 4122), (4124, 4148), (4152, 4160), (4162, 4177), (8192, 8212),
# (9219, 9219), (9222, 9224)]
@property
def supply_sensor(self):
return Sage2TemperatureReading(self, 7, 'Supply Sensor', summary=True)
@property
def firing_rate_requested(self):
return Sage2FiringRateReading(self, 8, 'Firing Rate (Actual)', summary=True)
@property
def fan_speed(self):
return Sage2Reading(self, 9, 'Fan Speed (Requested)', 'rpm', summary=True)
@property
def flame_signal(self):
return Sage2FlameSignalReading(self, 10, 'Flame Signal')
@property
def return_sensor(self):
return Sage2TemperatureReading(self, 11, 'Return Sensor', summary=True)
@property
def header_sensor(self):
return Sage2TemperatureReading(self, 13, 'Header Sensor', summary=True)
@property
def stack_sensor(self):
return Sage2TemperatureReading(self, 14, 'Stack Sensor', summary=True)
@property
def active_ch_setpoint(self):
return Sage2TemperatureReading(self, 16, 'Active CH Setpoint')
@property
def active_dhw_setpoint(self):
return Sage2TemperatureReading(self, 17, 'Active DHW Setpoint')
@property
def active_ll_setpoint(self):
return Sage2TemperatureReading(self, 18, 'Active LL Setpoint')
@property
def active_ch_operating_point(self):
return Sage2TemperatureReading(self, 25, 'Active CH Operating Point')
@property
def active_dhw_operating_point(self):
return Sage2TemperatureReading(self, 26, 'Active DHW Operating Point')
@property
def active_ll_operating_point(self):
return Sage2TemperatureReading(self, 27, 'Active LL Operating Point')
@property
def active_system_operating_point(self):
return Sage2TemperatureReading(self, 28, 'Active System Operating Point', summary=True)
@property
def active_system_setpoint(self):
return Sage2TemperatureReading(self, 29, 'Active System Setpoint', summary=True)
@property
def active_system_on_hysteresis(self):
return Sage2TemperatureReading(self, 30, 'Active System Hysteresis (on)')
@property
def active_system_off_hysteresis(self):
return Sage2TemperatureReading(self, 31, 'Active System Hysteresis (off)')
# BURNER CONTROL STATE
@property
def burner_state(self):
return Sage2BurnerStateReading(self, 33, 'Burner State', summary=True)
# @property
# def lockout_code(self):
# pass # 34
# @property
# def lockout_code(self):
# pass # 40
# SENSOR STATUS
@property
def supply_sensor_state(self):
return Sage2SensorStateReading(self, 48, 'Supply Sensor State')
@property
def return_sensor_state(self):
return Sage2SensorStateReading(self, 49, 'Return Sensor State')
@property
def stack_sensor_state(self):
return Sage2SensorStateReading(self, 51, 'Stack Sensor State')
@property
def header_sensor_state(self):
return Sage2SensorStateReading(self, 52, 'Header Sensor State')
@property
def remote_control_input_state(self):
return Sage2SensorStateReading(self, 53, '4-20mA Remote Control Input State')
# DEMAND & MODULATION STATUS
@property
def active_system_sensor(self):
return Sage2ModulationStateReading(self, 61, 'Active System Sensor', summary=True)
@property
def active_ll_sensor(self):
return Sage2ModulationStateReading(self, 62, 'Active LL Sensor')
# CENTRAL HEAT (CH) STATUS
@property
def setpoint_source_ch(self):
return Sage2SetpointSourceReading(self, 65, 'Setpoint Source (CH)')
@property
def demand_ch(self):
return Sage2DemandReading(self, 66, 'Demand (CH)', summary=True)
@property
def requested_rate_ch(self):
return Sage2FiringRateReading(self, 68, 'Requested Rate (CH)', summary=True)
@property
def demand_frost(self):
return Sage2DemandReading(self, 70, 'Demand (Frost)', summary=True)
@property
def active_ch_on_hysteresis(self):
return Sage2TemperatureReading(self, 71, 'Active CH Hysteresis (on)')
@property
def active_ch_off_hysteresis(self):
return Sage2TemperatureReading(self, 72, 'Active CH Hysteresis (off)')
@property
def active_sensor_ch(self):
return Sage2ModulationStateReading(self, 76, 'Active Sensor (CH)')
# DHW STATUS
@property
def active_sensor_dhw(self):
return Sage2ModulationStateReading(self, 79, 'Active Sensor (DHW)')
@property
def setpoint_source_dhw(self):
return Sage2SetpointSourceReading(self, 81, 'Setpoint Source (DHW)')
@property
def dhw_priority_counter(self):
return Sage2Reading(self, 82, 'DHW Priority Timer', 'sec')
@property
def demand_dhw(self):
return Sage2DemandReading(self, 83, 'Demand (DHW)', summary=True)
@property
def active_dhw_on_hysteresis(self):
return Sage2TemperatureReading(self, 88, 'Active DHW Hysteresis (on)')
@property
def active_dhw_off_hysteresis(self):
return Sage2TemperatureReading(self, 89, 'Active DHW Hysteresis (off)')
@property
def dhw_storage_time(self):
return Sage2Reading(self, 90, 'DHW Storage Time', 's')
# PUMP STATUS
@property
def pump_status_ch(self):
return Sage2PumpStatusReading(self, 96, 'Pump Status (CH)', summary=True)
@property
def pump_status_dhw(self):
return Sage2PumpStatusReading(self, 100, 'Pump Status (DHW)', summary=True)
@property
def pump_status_boiler(self):
return Sage2PumpStatusReading(self, 108, 'Pump Status (Boiler)', summary=True)
# STATISTICS
@property
def counter_burner(self):
return Sage2CounterReading(self, 128, 'Cycle Count (Burner)', 'cycles', summary=True)
@property
def counter_burner_hours(self):
return Sage2CounterReading(self, 130, 'Burner Run Time', 'hours', summary=True)
@property
def counter_ch_pump(self):
return Sage2CounterReading(self, 132, 'Cycle Count (CH Pump)', 'cycles', summary=True)
@property
def counter_dhw_pump(self):
return Sage2CounterReading(self, 134, 'Cycle Count (DHW Pump)', 'cycles', summary=True)
@property
def counter_boiler_pump(self):
return Sage2CounterReading(self, 138, 'Cycle Count (Boiler Pump)', 'cycles', summary=True)
@property
def counter_controller(self):
return Sage2CounterReading(self, 142, 'Cycle Count (Controller)', 'cycles', summary=True)
@property
def counter_controller_hours(self):
return Sage2CounterReading(self, 144, 'Controller Run Time', 'hours', summary=True)
# LEAD LAG STATUS
@property
def setpoint_source_ll(self):
return Sage2SetpointSourceReading(self, 162, 'Setpoint Source (LL)')
@property
def demand_ll(self):
return Sage2DemandReading(self, 164, 'Demand (LL)')
# EXTENDED SENSOR STATUS
@property
def outdoor_sensor(self):
return Sage2TemperatureReading(self, 170, 'Outdoor Sensor', summary=True)
@property
def outdoor_sensor_state(self):
return Sage2SensorStateReading(self, 171, 'Outdoor Sensor State', summary=False)
@property
def modulation_output(self):
return Sage2Reading(self,192, 'Modulation Output', 'enum', summary=False)
@property
def max_ch_rate(self):
return Sage2ModulationReading(self, 193, 'Maximum rate (CH)', summary=True)
@property
def max_dhw_rate(self):
return Sage2ModulationReading(self, 194, 'Maximum rate (DHW)', summary=True)
@property
def min_rate(self):
return Sage2ModulationReading(self, 195, 'Minimum rate', summary=True)
@property
def p_gain_ch(self):
return Sage2Reading(self, 216, 'CH P-gain', 'gain', summary=False)
@property
def i_gain_ch(self):
return Sage2Reading(self, 217, 'CH I-gain', 'gain', summary=False)
@property
def d_gain_ch(self):
return Sage2Reading(self, 218, 'CH D-gain', 'gain', summary=False)
# Implement this function. PRs welcome!
#
# @property
# def software_version(self):
# "Retrieve variable length OS version"
# return Sage2Reading(self, 186, 'OS Version', summary=True)
if __name__ == '__main__':
import serial
import sys
# Modbus/TCP bridge can be specified as an argument
host = len(sys.argv) == 2 and sys.argv[1] or 'localhost'
boiler = Sage2Boiler(slave=1, host=host, port=502)
print(boiler.tabulate(summary=True))