forked from baycom/tfrec
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathsensors.txt
136 lines (113 loc) · 5.4 KB
/
sensors.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
## tfrec - A SDR tool for receiving wireless sensor data
(c) 2017-2018 Georg Acher & Deti Fliegl, {acher|fliegl}(at)baycom.de
tfrec-supported sensors overview (TFA, LaCrosse, etc.)
(see todo.txt for unknown/unsupported sensors)
*) educated guess, not tested/verified. Please let me know if other sensors also work!
#) Success reported by users
X) Probably never supported
Type Temp1 Temp2 Humid ID LCD Baudrate Mod Sync Period Init-Msg Notes
30.3180.IT TFA_1 X - X Unique 15bit X 38400 FM-NRZS 2d d4 10s b26-00-56
30.3181.IT TFA_1 X - - Unique 15bit X 38400 FM-NRZS 2d d4 10s b26-00-56 External temp sensor
30.3199.IT TFA_1 X - - Unique 15bit X 38400 FM-NRZS 2d d4 10s ? Pool sensor
30.3143.IT TFA_2 X X - Random 6bit X 17240 FM-NRZ 2d d4 4s 301 External temp sensor
30.3144.IT TFA_2 X - X Random 6bit X 17240 FM-NRZ 2d d4 4s 302
30.3146.IT* TFA_2 X - - Random 6bit - 17240 FM-NRZ 2d d4 4s -
30.3147.IT# TFA_2 X - - Random 6bit - 17240 FM-NRZ 2d d4 4s -
30.3159.IT# TFA_2 X - - Random 6bit - 17240 FM-NRZ 2d d4 4s -
30.3155.WD TFA_3 X - X Random 6bit X 9600 FM-NRZ 2d d4 4s p32
30.3156.WD# TFA_3 X - - Random 6bit - 9600 FM-NRZ 2d d4 4s -
30.3183.IT TFA_3 X - X ? X 9600 temp/humidity sensor with display for device 30.3042.IT
30.3303.02 TFA_WHB X - X 6Byte X 6000 PSK-NRZM 4b2dd42b 420s? ? WeatherHub temp/humidity sensor
30.3305.02 TFA_WHB X - X 6Byte X 6000 PSK-NRZM 4b2dd42b 420s+ P58-r19 WeatherHub temp/humidity/wetness sensor
30.3306.02X TFA_WHP - - - none - ~4000 FM-NRZ (ea 44) - - WeatherHub rain sensor, simple mode
30.3306.02 TFA_WHB X - - 6Byte - 6000 PSK-NRZM 4b2dd42b 7200s+ - WeatherHub rain sensor (= MA10650)
30.3307.02 TFA_WHB - - - 6Byte - 6000 PSK-NRZM 4b2dd42b 420s - WeatherHub wind sensor (= MA10660)
30.3311.02 TFA_WHB - - - 6Byte - 6000 PSK-NRZM 4b2dd42b 21600s+ - WeatherHub door sensor
35.1147.01 TFA_WHB X X 2 6Byte X 6000 PSK-NRZM 4b2dd42b ? - WeatherHub station, indoor + outdoor sensor
30.3060.01 TFA_WHB X +3 4 6Byte X 6000 PSK-NRZM 4b2dd42b ? - WeatherHub station, indoor + 3*outdoor sensors
30.3302.02 TFA_WHB X X X 6Byte X 6000 PSK-NRZM 4b2dd42b 120 - WeatherHub temp/humidity + cable temp sensor (extended range -50...+110C)
30.3304.02 TFA_WHB X X X 6Byte X 6000 PSK-NRZM 4b2dd42b ? - WeatherHub temp/humidity + cable temp sensor
30.5043.01 TFA_WHB X - X 6Byte X 6000 PSK-NRZM 4b2dd42b ? - WeatherHub Cosy Radar (3h/24h/7d/24h humidity average)
Notes:
30.3181/Temp1, 30.3143/Temp2, 30.3304.02/Temp2: External temperature sensor (NTC 10k @ 25 degC)
30.3305 (WeatherHub wetness sensor)
(+) value changes for temperature/humidity trigger message after 60s, wetness events sends immediately,
otherwise messages are repeated every 420s.
30.3306.02 (WeatherHub door sensor):
... has two transmission modes:
- 16 fixed content packets (NRZ) with 5 bytes per pulse with zig-zagged center frequency per telegram (not supported)
- 2 packets in PSK/NRZS/G3RUH with 41 bytes each, containing ID, values, etc.
- 2.5ml/pulse @ area 100cm^2 -> 250ml/m^2 = 0.25mm/m^2 per pulse
- Internal temperature sensor is not very precise
(+) Messages are repeated every 2h without rains pulses
30.3311.02 (WeatherHub door sensor):
- State open (0): magnet not near sensor
(+) If no open/close events occur, messages are repeated every 6h (21600s)
35.1147.01 (station, "Coloris", uses external sensor 30.3224.02.IT)
- Sends internal and outdoor TH values
30.3060.01 (station, "Klima@Home", uses 3* external sensor KlimaLoggPro 30.3180.IT)
- Sends internal and three outdoor TH values
30.5043.01 (station)
- Has internal temperatur and humidity, averages humidity over 3h/24h/7d/30d
-----------------------------------------------------------------------------
Sensor vs. station zoo (according to TFA website chaos + own googling, not verified)
Stations for TFA1-sensors ("KlimaLogg Pro")
30.3039.IT
30.3053.IT
30.3060.01 ("Klima@Home"/WeatherHub collector)
Stations for TFA2-sensors (type 1)
30.3009.IT
30.3018.IT
30.3032.IT
35.1026.IT
35.1044.IT
35.1048.IT
35.1064.IT
35.1068.IT
35.1070.IT
35.1076.IT
35.1089.IT
Stations for TFA2-sensors (type 2?)
30.3013.IT
30.3030.IT
35.1036.IT
35.1045.IT
35.1070.IT
35.1078.IT
35.1115 "Square" (sensors 30.3188, 30.3187, 30.3159)
35.1117 "Quantia" (sensors 30.3188, 30.3187, 30.3159)
35.1121 "Square+" (sensors 30.3188, 30.3187, 30.3159)
Stations for TFA3-sensors (Weather direct)
35.5000.IT
35.5001.IT
35.5002.IT
35.5003.IT
35.5010.IT
35.5011.IT
35.5012.IT
35.5014.IT
35.5015.IT
35.5016.IT
35.5017.IT
35.5018.IT
35.5019.IT
35.5020.IT
35.5022.IT
35.5024.IT
35.5025.IT
35.5027.IT
35.5028.IT
35.5030.IT
35.5031.IT
35.5034.IT
35.5035.IT
35.5036.IT
35.5037.IT
35.5038.IT
35.5039.IT
35.5040.IT
35.5041.IT
35.5042.IT
35.5045.IT
35.5049.IT
35.5051.IT