Metadynamics does not work with small time step #802
Comments
We encountered this issue in metadynamics on the vanillin molecule with the coordinates
and the input
The result does not appear to be fully reproducible, though. I wonder if another issue is that atoms can be placed on top of each other in the random initialization. |
For instance, running
on my laptop with
after which xtb crashed. However, other runs worked fine. |
The biasing potential in metadynamics is controlled by the MD step number. This means that the biasing potential gets switched on instantaneously when a small time step is used, resulting in the system exploding. For instance, when running systems with hydrogens with
shake=0
and the usual 0.5 fs time step, one experiences an explosion already in the initial dynamics run since the starting configuration is included in the metadynamics potential.The correct way to switch on the biasing potential is to do it as a function of actual time.