Notifications
You must be signed in to change notification settings - Fork 93
/
Copy pathPropOCD.spin
242 lines (176 loc) · 7.8 KB
/
PropOCD.spin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
{{
+-------------------------------------------------+
| OpenOCD Binary Protocol |
| Interface Object |
| |
| Authors: Ben Gardiner & Joe Grand |
| Copyright (c) 2020 Ben Gardiner & Joe Grand |
| |
| Distributed under a Creative Commons |
| Attribution 3.0 United States license |
| http://creativecommons.org/licenses/by/3.0/us/ |
+-------------------------------------------------+
Program Description:
This object provides the low-level communication interface for OpenOCD. It emulates
the binary protocol used by the Bus Pirate (http://dangerousprototypes.com/docs/Bus_Pirate#JTAG
and https://github.com/DangerousPrototypes/Bus_Pirate/blob/master/Firmware/OpenOCD.c)
}}
CON
' Serial terminal
BaudRate = 115_200
RxPin = |<31
TxPin = |<30
' Control characters
CAN = 24 ''CAN: Cancel (Ctrl-X)
MAX_RX_DELAY_MS = 100 ' Wait time (in ms) for the each byte in commands to be sent before aborting
CMD_UNKNOWN = $00
CMD_PORT_MODE = $01 ' port type
CMD_FEATURE = $02 ' hardware-specific configuration
CMD_READ_ADCS = $03 ' read A/Ds
'CMD_TAP_SHIFT = $04 ' shift TAP (old protocol)
CMD_TAP_SHIFT = $05 ' shift TAP
CMD_ENTER_OOCD = $06 ' enter binary (OCD) mode
CMD_UART_SPEED = $07 ' UART speed select
CMD_JTAG_SPEED = $08 ' JTAG speed select
CMD_RESET = $0F ' reset (from buspirate_jtag_reset in OpenOCD buspirate.c)
FEATURE_LED = $01 ' LED on/off
FEATURE_VREG = $02 ' voltage regulator on/off
FEATURE_TRST = $04 ' set TRST logic state
FEATURE_SRST = $08 ' set SRST logic state
FEATURE_PULLUP = $10 ' pull up resistors on/off
SERIAL_NORMAL = 0
SERIAL_FAST = 1 ' ~1 MHz
MODE_HIZ = 0 ' high impedance (hi Z), input
MODE_JTAG = 1 ' push-pull, output
MODE_JTAG_OD = 2 ' open drain, output
MAX_BIT_SEQUENCES = 8192 ' Maximum number of bit sequences allowed per CMD_TAP_SHIFT
VAR
long vCmd ' Address of global buffer from top object
OBJ
g : "JTAGulatorCon" ' JTAGulator global constants
u : "JTAGulatorUtil" ' JTAGulator general purpose utilities
pst : "JDCogSerial" ' UART/Asynchronous Serial communication engine (Carl Jacobs, http://obex.parallax.com/object/298)
jtag : "PropJTAG" ' JTAG/IEEE 1149.1 low-level methods
PUB Go(tdi, tdo, tck, tms, bufPtr) | ctr
pst.Start(RxPin, TxPin, BaudRate) ' Configure UART
vCmd := bufPtr
u.LEDRed ' We are initialized and ready to go
u.TXSEnable ' Enable level shifter outputs
u.Set_Pins_High(0, g#MAX_CHAN) ' In case there is a signal on the target that needs to be held HIGH, like TRST# or SRST#
jtag.Config(tdi, tdo, tck, tms) ' Configure JTAG
' Start command receive/process cycle
repeat
byte[vCmd][0]:=pst.Rx
case byte[vCmd][0]
CAN: ' If Ctrl-X (CAN) character received, exit OpenOCD mode
pst.Stop ' Stop serial communications
return ' Go back to main JTAGulator mode
'the 'short' commands follow; all are 1 byte, no parameters
CMD_UNKNOWN: ' From buspirate_bbio_enable and buspirate_jtag_reset in OpenOCD buspirate.c
u.LEDRed ' Ensure LED turns back to red when OpenOCD is closed
pst.Str(@BBIO)
CMD_ENTER_OOCD:
pst.Str(@OCD)
CMD_READ_ADCS: ' Not supported
pst.Tx(CMD_READ_ADCS) ' Send acknowledgement
pst.Tx(8) ' Number of bytes
repeat 8
pst.Tx(0)
'remaining commands are 'long' commands, which take 1 or more parameters
CMD_PORT_MODE: ' Not supported
if (GetMoreParamBytes(1) == -1)
next
case byte[vCmd][1]
MODE_HIZ:
next
MODE_JTAG:
next
MODE_JTAG_OD:
next
CMD_FEATURE:
if (GetMoreParamBytes(2) == -1)
pst.Tx(0)
next
case byte[vCmd][1]
FEATURE_LED:
next
FEATURE_VREG:
next
FEATURE_TRST:
next
FEATURE_SRST:
next
FEATURE_PULLUP:
next
CMD_JTAG_SPEED: ' Not supported
if (GetMoreParamBytes(2) == -1)
next
CMD_UART_SPEED: ' Not supported
if (GetMoreParamBytes(1) == -1)
pst.Tx(0)
next
pst.Tx(CMD_UART_SPEED) ' Send acknowledgement
pst.Tx(SERIAL_NORMAL)
CMD_TAP_SHIFT:
if (++ctr // 10) == 0
!outa[g#LED_G] ' Toggle LED between red and yellow
if (GetMoreParamBytes(2) == -1)
pst.Tx(0)
Do_Tap_Shift
CMD_RESET:
next
other: ' Invalid byte
pst.Tx(0)
PRI Do_Tap_Shift | num_sequences, num_bytes, bits, value, i
' based on HydraBus implementation of Bus Pirate binary protocol
' https://github.com/hydrabus/hydrafw/blob/master/src/hydrabus/hydrabus_mode_jtag.c
' calculate number of requested bit sequences
num_sequences := byte[vCmd][1]
num_sequences <<= 8
num_sequences |= byte[vCmd][2]
if num_sequences > MAX_BIT_SEQUENCES ' Upper bounds check
num_sequences := MAX_BIT_SEQUENCES
pst.Tx(CMD_TAP_SHIFT) ' Send acknowledgement
pst.Tx(byte[vCmd][1])
pst.Tx(byte[vCmd][2])
' calculate number of bytes to read
num_bytes := ((num_sequences + 7) / 8) * 2
' get bytes from OpenOCD with the TDI and TMS data to shift into target
if (GetMoreParamBytes(num_bytes) == -1)
pst.Tx(0)
return ' exit if we don't receive the correct number of bytes
i := 0
repeat while (num_sequences > 0)
if (num_sequences > 8) ' Do 8 bits at a time until the last set
bits := 8
else
bits := num_sequences
value := OpenOCD_Shift(byte[vCmd][i+1] {TDI}, byte[vCmd][i+2] {TMS}, bits)
pst.Tx(value & $FF)
i += 2
num_sequences -= bits
PRI OpenOCD_Shift(ocd_tdi, ocd_tms, num_bits) : ocd_tdo | num ' Shift data from OpenOCD into target and receive result
num := num_bits
repeat while (num_bits > 0)
if (ocd_tms & 1)
jtag.TMS_High
else
jtag.TMS_Low
if (ocd_tdi & 1)
jtag.TDI_High
else
jtag.TDI_Low
ocd_tdo <<= 1
ocd_tdo |= jtag.TDO_Read
ocd_tdi >>= 1 ' Shift to the next bit in the sequence
ocd_tms >>= 1
num_bits -= 1 ' Adjust number of remaining bits
ocd_tdo ><= num ' Bitwise reverse since LSB came in first (we want MSB to be first)
PRI GetMoreParamBytes(num) : val | i
repeat i from 1 to num
if (byte[vCmd][i]:=pst.RxTime(MAX_RX_DELAY_MS)) < 0
val:=-1
DAT
ORG
BBIO byte "BBIO1", 0
OCD byte "OCD1", 0