The response of DC motor was then calculated by Ziegler-Nichols method. We selected the following set of points (𝑡a, 𝑦a) and (𝑡b, 𝑦b). The first point corresponds to output of step response at a value of 35.3% and the second point corresponds to output of step response at a value of 85.3%. By using this method, we got open loop step response values of DC motor given as follows:
𝑡a = 8 sec, 𝑦a = 14.52
𝑡b = 37.7 sec, 𝑦b = 35.09
and dc gain 𝛽 = 41.1449
Using Ziegler-Nichols rules we derived PID controller parameters.
Kp = 0.8000
Ki = 0.6380
Kd = 0.2508
By using the above values of K𝑝, K𝑖, and K𝑑, PID controller was designed. PID controller was tuned keeping the objective that settling time ts and rise time tr should be minimum.