After flashing Benisphere, Modules no longer Output #78

Open
velvetwafer opened this issue Jul 16, 2023 · 2 comments
Open

After flashing Benisphere, Modules no longer Output #78

velvetwafer opened this issue Jul 16, 2023 · 2 comments

Comments

@velvetwafer
Copy link

velvetwafer commented Jul 16, 2023

I tried Benisphere on my 1u O&C Modules, which were working fine with Stock Firmware and regular Hemisphere... but with Benisphere, suddenly there is no Output on the A to D Jacks...Output doesnt even return after i flashed Stock Firmware, or regular hemisphere. i have two paperweights now. (both worked fine before flashing...Id appreciate some Help with this. i tried recalibrating in stock firmware...output is stuck at -11 volt

@djphazer
Copy link

djphazer commented Jul 16, 2023

If they are Plum Audio or 4ROBOTS units, you probably need a +VOR firmware build!
Try one of my newer builds - https://github.com/djphazer/O_C-BenisphereSuite/releases

@velvetwafer
Copy link
Author

Youre heaven sent...this worked! Thank you for the quick Solution (i was already freaking out, reflowing most of the connections :D