From 1ca93a393e85a6779de3961851ad7e786a79deb4 Mon Sep 17 00:00:00 2001
From: Hugo Oliveira <ocehugo@gmail.com>
Date: Mon, 21 Oct 2019 12:07:03 +1100
Subject: [PATCH 1/2] Remove extra parenthesis

---
 Preprocessing/aquatrackaPP.m | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/Preprocessing/aquatrackaPP.m b/Preprocessing/aquatrackaPP.m
index d7c314a5f..dc99ab366 100644
--- a/Preprocessing/aquatrackaPP.m
+++ b/Preprocessing/aquatrackaPP.m
@@ -62,7 +62,7 @@
     offset(i)       = str2double(readProperty(['offset' analogAquatracka{i}], ParamFile));
 end
 
-commentsAquatracka = {[ getCPHLcomment('factory','430nm','685nm') ' Data converted from analogic input with scaleFactor=' num2str(scaleFactor(1)) ', offset=' num2str(offset(1))) ' .'], ...
+commentsAquatracka = {[ getCPHLcomment('factory','430nm','685nm') ' Data converted from analogic input with scaleFactor=' num2str(scaleFactor(1)) ', offset=' num2str(offset(1)) ' .'], ...
           ['Turbidity data in FTU '...
           'computed from bio-optical sensor raw counts measurements using factory calibration coefficient. The '...
           'fluorometre is used as a nephelometre equipped with a 440nm peak wavelength LED to irradiate. '], ...

From 84600a67e4efc9320e6d52c9e061f2bfff198767 Mon Sep 17 00:00:00 2001
From: Hugo Oliveira <ocehugo@gmail.com>
Date: Mon, 21 Oct 2019 12:24:47 +1100
Subject: [PATCH 2/2] add test for aquatrackaPP

---
 test/testOnlyCPHL.m | 20 ++++++++++++++++++++
 1 file changed, 20 insertions(+)

diff --git a/test/testOnlyCPHL.m b/test/testOnlyCPHL.m
index 6bf88baa3..e26ebbe9c 100644
--- a/test/testOnlyCPHL.m
+++ b/test/testOnlyCPHL.m
@@ -111,6 +111,26 @@ function test_wqmdat(testCase, wqmdat_reader, wqmdat_v000_param, mode)
             assert(check_cphl(data));
         end
 
+        function test_aquatrackapp(~,sbe19p_reader,sbe19p_v000_param,mode)
+            data = sbe19p_reader({sbe19p_v000_param},mode);
+            %fake volt_cphl variable
+            for k=1:length(data.variables)
+                if contains(data.variables{k}.name,'CPHL')
+                    newvar = data.variables{k};
+                    newvar.name = 'volt_CHL';
+                    data.variables{end+1} = newvar;
+                    break
+                end
+            end
+            output = aquatrackaPP({data},'qc',0);
+            data = output{1};
+            comment = data.variables{end}.comment;
+            assert(check_cphl(data));
+            assert(contains(comment,'analogic input'));
+            assert(contains(comment,'scaleFactor='));
+            assert(contains(comment,'offset='));
+        end
+
     end
 
 end