[cmd]+CR+LF general command format
V0100 - {mV*10}set 1 V (V1000 set 10V)
I0500 - {mA}set 0500mA current limit
B0500 - {mV*10} set voltage protection to 5V
D0500 - {mA}set 0500mA voltage protection
E0200 - {W/10} 20W power protection
H01 - [hours] time protection
M20 - {min} time protection
S20 - {sec} time protection
X - enable time protection
Y - disable time protection
N - output ON
F - output off
Q - start reporting W - close reporting
When you send "Q" it starts periodic message from power supply
periodic message example:
0199A 0700A 0139A 0A 029A 0A 0A 1A - on
0000A 0000A 0000A 0A 029A 0A 0A 0A - off
0000A 0000A 0000A 0A 029A 0A 2A 0A - short Circuit
0058A 0098A 0005A 0A 028A 1A 0A 1A - current limit ON ()
Periodic mesage format:
0199A 0700A 0139A 0A 029A 0A 0A 1A
[voltage,{V/100}: 1.99]A [ampere{A/1000}:0.700]A [watt{W/10}:1.39W]A [unknown] 0A [temp:029deg] [CC/CV=0]0A [error type]0A [on/0ff:1]A
Error type:
0 - OK - non errors
1 - OV - Over voltage protection
2- OC - over current protection
3 - OT - over time protection
CC/CV - sourse type mode:
CC - constant current mode [CC/CV = 1]
CV - constant voltage mode [CC/CV = 0]