HVAC Autosizing Limits #152

Open
12 of 20 tasks
willf opened this issue Feb 12, 2025 · 0 comments
Open
12 of 20 tasks

HVAC Autosizing Limits #152

willf opened this issue Feb 12, 2025 · 0 comments

Comments

@willf
Copy link

willf commented Feb 12, 2025

Pull Request Description

Addresses NREL#1154.
Tests NREL/OpenStudio-HPXML#1584 and NREL/OpenStudio-HPXML#1558.
Supersedes NREL#1179.

Add sample files:

  • national_upgrades_HPs_TMY3.yml and national_upgrades_HPs_AMY2018.yml
    • Case 1: Baseline Stock - TMY3
    • Case 2: Baseline Upgrade - EnergyStar Heat Pump, Existing System Backup
    • Case 3: Baseline Upgrade - EnergyStar Heat Pump, Electric Backup
    • Case 4: Baseline Upgrade - EnergyStar Heat Pump, Existing System Backup, Compressor Lockout
      • A: 20F
      • B: 30F
      • C: 40F
    • Case 5: New Dual-Fuel System, Backup Lockout
      • A: 1.67F
      • B: 18.33F
      • C: 35F
    • Case 7: Heat Pump Selection – EnergyStar Mid Efficiency, Electric Backup
    • Case 8: Heat Pump Selection – Typical Cold Climate
    • Case 9: Heat Pump Selection – High COP, Cold-Temperature
    • Case 10: Heat Pump Selection – High COP, Part Load
    • Case 11: Heat Pump Selection – High Capacity, Cold Temperature
    • Case 12: Heat Pump Selection - DOE CCHP Challenge
    • Case 13: Heat Pump Selection - TBD
    • Case 14: Heat Pump Sizing – Typical Cold Climate (Case 8)
      • A
        • Ducted: 25% between Autosize Limit and MaxLoad
        • Ductless: 25% between ACCA and MaxLoad
      • B
        • Ducted: 50%
        • Ductless: 50%
      • C
        • Ducted: MaxLoad
        • Ductless: ACCA
      • D
        • Ducted: ACCA
        • Ductless: skip
    • Case 15: Heat Pump Sizing - EnergyStar Heat Pump, Electric Backup (Case 3)
      • A
        • Ducted: 25% between Autosize Limit and MaxLoad
        • Ductless: 25% between ACCA and MaxLoad
      • B
        • Ducted: 50%
        • Ductless: 50%
      • C
        • Ducted: MaxLoad
        • Ductless: ACCA
      • D
        • Ducted: ACCA
        • Ductless: skip

Add cost multipliers:

  • upgrade_costs.air_flow_rate_heating_system_primary_cfm
  • upgrade_costs.air_flow_rate_heating_system_secondary_cfm
  • upgrade_costs.air_flow_rate_cooling_system_primary_cfm
  • upgrade_costs.air_flow_rate_heat_pump_backup_primary_cfm

Checklist

Not all may apply:

  • Tests (and test files) have been updated
  • Documentation has been updated
  • Changelog has been updated
  • openstudio tasks.rb update_measures has been run
  • No unexpected regression test changes on CI (checked comparison artifacts)