Notifications
You must be signed in to change notification settings - Fork 11
/
Copy pathcheck_cciss.pl
executable file
·448 lines (430 loc) · 17.5 KB
/
check_cciss.pl
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
#!/bin/sh
#
# HP Smart Array Hardware status plugin for Nagios | Written by Simone Rosa
# with HP Array Configuration Utility CLI | info [X]
# and HPE Smart Storage Administrator | simonerosa
# (hpacucli / hpssacli) | {X} it
#
#
# Description:
#
# This plugin checks hardware status for Smart Array Controllers,
# using the HP Array Configuration Utility CLI / HPE Smart Storage Administrator.
# (Array, controller, cache, battery, etc...)
#
#
# Usage: ./check_cciss [-v] [-p] [-e <number>] [-E <name>] [-b] [-s] [-d]
#
# -v = show status and informations about RAID
# -p = show detail for physical drives
# -e <number> = exclude slot number
# -E <name> = exclude chassis name
# -b = exclude battery/capacitor/cache status check
# -s = detect controller with HPSA driver (Hewlett Packard Smart Array)
# -d = use for debug (command line mode)
# -h = help information
# -V = version information
#
#
# !!!!!! NOTE: !!!!!!
#
# HP Array Configuration Utility CLI (hpacucli) and
# HPE Smart Storage Administrator (hpssacli) need administrator rights.
#
# Please add this line to /etc/sudoers :
# --------------------------------------------------
# nagios ALL=NOPASSWD: /usr/sbin/hpacucli, /usr/sbin/hpssacli
#
# !!!!!!! NOTE: !!!!!!
#
# - Please update the hpacucli to the current version (today 9.40) or >8.70
# - If you are using hpssacli (today HPE Smart Storage Administrator CLI 2.40.13.0) change hpssacli permissions:
# # chmod 555 /usr/sbin/hpssacli (default are 500 root:root)
# # chmod 555 /usr/sbin/hpacucli
# - HP Proliant G9 work correctly with "hpssacli". Please NOT install "hpacucli"
# - RHEL7 use "ssacli":
# # ln -s /usr/sbin/ssacli /usr/sbin/hpssacli
# # and check /etc/sudoers user (example: nrpe ALL=NOPASSWD: /usr/sbin/hpacucli, /usr/sbin/hpssacli)
#
# !!!!!!!!!!!!!!!!!!!
#
# Examples:
#
# ./check_cciss
# ----------------
# RAID OK
#
# ./check_cciss -v
# -------------------
# RAID OK: Smart Array 6i in Slot 0 array A logicaldrive 1 (67.8 GB, RAID 1+0, OK)
# [Controller Status: OK Cache Status: OK Battery Status: OK]
#
# RAID CRITICAL - HP Smart Array Failed: Smart Array 6i in Slot 0 (Embedded) \
# array A logicaldrive 1 (33.9 GB, RAID 1, Interim Recovery Mode) \
# physicaldrive 1:0 (port 1:id 0 , Parallel SCSI, --- GB, Failed)
#
# RAID WARNING - HP Smart Array Rebuilding: Smart Array 6i in Slot 0 (Embedded) \
# array A logicaldrive 1 (33.9 GB, RAID 1, Recovering, 26% complete) \
# physicaldrive 1:0 (port 1:id 0 , Parallel SCSI, 36.4 GB, Rebuilding)
#
# ./check_cciss -v -p
# --------------------
# RAID OK: Smart Array 6i in Slot 0 (Embedded) array A logicaldrive 1 (33.9 GB, RAID 1, OK)
# physicaldrive 2:0 (port 2:id 0 , Parallel SCSI, 36.4 GB, OK)
# physicaldrive 2:1 (port 2:id 1 , Parallel SCSI, 36.4 GB, OK)
# physicaldrive 1:5 (port 1:id 5 , Parallel SCSI, 72.8 GB, OK, spare)
# [Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK]
#
# RAID CRITICAL - HP Smart Array Failed: Smart Array 6i in Slot 0 (Embedded) \
# array A logicaldrive 1 (33.9 GB, RAID 1, Interim Recovery Mode) \
# physicaldrive 1:0 (port 1:id 0 , Parallel SCSI, --- GB, Failed) \
# physicaldrive 1:1 (port 1:id 1 , Parallel SCSI, 36.4 GB, OK)
#
# RAID WARNING - HP Smart Array Rebuilding: Smart Array 6i in Slot 0 (Embedded) \
# array A logicaldrive 1 (33.9 GB, RAID 1, Recovering, 26% complete) \
# physicaldrive 1:0 (port 1:id 0 , Parallel SCSI, 36.4 GB, Rebuilding) \
# physicaldrive 1:1 (port 1:id 1 , Parallel SCSI, 36.4 GB, OK)
#
# ./check_cciss -v -b
# ----------------
#
# RAID OK: Smart Array 6i in Slot 0 (Embedded) array A logicaldrive 1 (33.9 GB, RAID 1, OK) [Controller Status: OK]
#
# [insted of]
# RAID CRITICAL - HP Smart Array Failed: Smart Array 6i in Slot 0 (Embedded) \
# Controller Status: OK Cache Status: Temporarily Disabled \
# Battery/Capacitor Status: Failed (Replace Batteries/Capacitors)
#
#
# ChangeLog:
#
# 2017/04/28 (1.15)
# - Added debug for hpacucli/hpssacli section
# - Added note for hpssacli (today HPE Smart Storage Administrator CLI)
# # chmod 555 /usr/sbin/hpssacli (default are 500 root:root)
# # chmod 555 /usr/sbin/hpacucli
# - Added note for RHEL7 (ssacli and sudoers user)
# - Script tested with HP Proliant G9
#
# 2017/02/25 (1.14)
# - Updated headers for versions from 1.8 to 1.13
#
# 2017/01/23 (1.13)
# - Support hpssacli in addition to hpacucli
# - Added cli flag '-b' to exclude battery/capacitor/cache status check
#
# 2013/11/20 (1.12)
# - Auto-detect the HPSA driver (tested with DL360/380 G6 with Ubuntu 12.04 LTS)
#
# 2012/07/16 (1.11)
# - Fixed little NRPE description output issue (only in one physicaldrive critical output)
#
# 2012/04/04 (1.10)
# - Critical states have priority over warning states
# - Fixed check physical drives for predicted failures without show detail (-p)
# - Fixed check physical drives for predicted failures in "chassis name" mode
#
# 2012/03/06 (1.9)
# - Increased debug verbosity
# - Added arguments to detect controller with HPSA driver (Hewlett Packard Smart Array) (-s)
# - Recognize required firmware upgrades
# - Don't confuse messages about a new fimrware with a chassis-error
# - Check physical drives for predicted failures
# - Added arguments to show detail for physical drives (-p)
# - Check the state of the cache (a dead battery will turn the cache off)
# (thanks to Casper Gielen and Kim Hagen)
#
# 2008/10/06 (1.8)
# - Added support for chassis name (example MSA500)
# - Added arguments to exclude slot number (-e <n>) and chassis name (-E <name>)
# - Added "Recovering" status reporting
# - Updated for hpacucli 8.10 version
#
# 2008/07/12 (1.7)
# - Changed command argument support to use getopts and dropped the now unnecessary -N and -c options
# (thanks to Reed Loden)
#
# 2008/07/06 (1.6)
# - Added support for multiple arrays
# (thanks to Reed Loden)
#
# 2008/05/30 (1.5)
# - Added support for checking cache and battery status; added autodetection of slot number; corrected typo
# (thanks to Reed Loden)
#
# 2006/01/25 (1.4)
# - Changed "Rebuilding" grep with "Rebuild" for capture "Ready for Rebuild" status
# (thanks to Loris A.)
#
# 2005/12/24 (1.3)
# - Added STATE_UNKNOWN when hpacucli command failed (if sudo exit with error)
# (thanks to Tim Hughes)
#
# 2005/10/10 (1.2)
# - Now it's compatible with "Compaq Smart Array"
# (suggested by Hans Engelen)
#
# 2005/10/07 (1.1)
# - Debug messages
#
# 2005/10/06 (1.0)
# - First production version
#
PATH=/bin:/sbin:/usr/bin:/usr/sbin:/usr/local/bin:/usr/local/sbin
PROGNAME=`basename $0`
PROGPATH=`echo $0 | sed -e 's,[\\/][^\\/][^\\/]*$,,'`
REVISION=`echo '$Revision: 1.15 $' | sed -e 's/[^0-9.]//g'`
HPSA="0"
DEBUG="0"
VERBOSE="0"
HPPROC="/proc/driver/cciss/cciss"
HPSCSIPROC="/proc/scsi/scsi"
COMPAQPROC="/proc/driver/cpqarray/ida"
hpacucli="/usr/sbin/hpacucli"
hpssacli="/usr/sbin/hpssacli"
. /usr/lib/nagios/plugins/utils.sh
print_usage() {
echo ""
echo "Usage: $PROGNAME [-v] [-p] [-e <number>] [-E <name>] [-b] [-s] [-d]"
echo "Usage: $PROGNAME [-h]"
echo "Usage: $PROGNAME [-V]"
echo ""
echo " -v = show status and informations about RAID"
echo " -p = show detail for physical drives"
echo " -e <number> = exclude slot number"
echo " -E <name> = exclude chassis name"
echo " -b = exclude battery/capacitor/cache status check"
echo " -s = detect controller with HPSA driver (Hewlett Packard Smart Array)"
echo " -d = use for debug (command line mode)"
echo " -h = help information"
echo " -V = version information"
echo ""
echo " === NOTE: ==="
echo ""
echo " HP Array Configuration Utility CLI (hpacucli) and"
echo " HPE Smart Storage Administrator (hpssacli) need administrator rights."
echo ""
echo " Please add this line to /etc/sudoers"
echo " --------------------------------------------------"
echo " nagios ALL=NOPASSWD: /usr/sbin/hpacucli, /usr/sbin/hpssacli"
echo ""
echo " - Please update the hpacucli to the current version (today 9.40) or >8.70"
echo " - If you are using hpssacli (today HPE Smart Storage Administrator CLI 2.40.13.0) change hpssacli permissions:"
echo " # chmod 555 /usr/sbin/hpssacli (default are 500 root:root)"
echo " # chmod 555 /usr/sbin/hpacucli"
echo " - HP Proliant G9 work correctly with \"hpssacli\" Please NOT install \"hpacucli\""
echo " - RHEL7 use \"ssacli\":"
echo " # ln -s /usr/sbin/ssacli /usr/sbin/hpssacli"
echo " # and check /etc/sudoers user (example: nrpe ALL=NOPASSWD: /usr/sbin/hpacucli, /usr/sbin/hpssacli)"
echo ""
echo " ============="
}
print_help() {
print_revision $PROGNAME $REVISION
echo ""
print_usage
echo ""
echo "This plugin checks hardware status for Smart Array Controllers,"
echo "using the HP Array Configuration Utility CLI / HPE Smart Storage Administrator."
echo ""
support
exit 0
}
while getopts "N:cvpbsde:E:Vh" options
do
case $options in
N) ;;
c) ;;
v) VERBOSE=1;;
p) PHYSICAL_DRIVE=1;;
s) HPSA=1;;
d) DEBUG=1;;
e) EXCLUDE_SLOT=1
excludeslot="$OPTARG";;
E) EXCLUDE_CH=1
excludech="$OPTARG";;
b) EXCLUDE_BATTERY=1;;
V) print_revision $PROGNAME $REVISION
exit 0;;
h) print_help
exit 0;;
\?) print_usage
exit 0;;
*) print_usage
exit 0;;
esac
done
# Use HPSA driver (Hewlett Packard Smart Array)
if [ "$HPSA" = "1" -o -d /sys/bus/pci/drivers/hpsa ]; then
COMPAQPROC="/proc/scsi/scsi"
fi
# Check if "HP Smart Array" is present
raid=`cat $HPPROC* 2>&1`
status=$?
if [ "$DEBUG" = "1" ]; then
echo "### Check if \"HP Smart Array\" ($HPPROC) is present >>>\n"${raid}"\n"
fi
if test ${status} -eq 1; then
raid=`cat $COMPAQPROC* 2>&1`
status=$?
if [ "$DEBUG" = "1" ]; then
echo "### Check if \"HP Smart Array\" ($COMPAQPROC) is present >>>\n"${raid}"\n"
fi
if test ${status} -eq 1; then
echo "RAID UNKNOWN - HP Smart Array not found"
exit $STATE_UNKNOWN
fi
fi
# Check if "HP Array Utility CLI" is present
if [ "$DEBUG" = "1" ]; then
echo "### Check if \"hpacucli\" is present >>>\n"
fi
if [ ! -x $hpacucli ]; then
if [ "$DEBUG" = "1" ]; then
echo "### \"hpacucli\" is NOT present >>>\n"
echo "### Check if \"hpssacli\" is present >>>\n"
fi
if [ -x $hpssacli ]; then
if [ "$DEBUG" = "1" ]; then
echo "### \"hpssacli\" is present >>>\n"
fi
hpacucli='/usr/sbin/hpssacli'
else
echo "ERROR: hpacucli or hpssacli tools should be installed and check sudoers/permissions (see the notes above)"
exit $STATE_UNKNOWN
fi
fi
# Check if "HP Controller" work correctly
check=`sudo -u root $hpacucli controller all show status 2>&1`
status=$?
if [ "$DEBUG" = "1" ]; then
echo "### Check if \"HP Controller\" work correctly >>>\n"${check}"\n"
fi
if test ${status} -ne 0; then
echo "RAID UNKNOWN - $hpacucli did not execute properly : "${check}
exit $STATE_UNKNOWN
fi
# Get "Slot" & exclude slot needed
if [ "$EXCLUDE_SLOT" = "1" ]; then
slots=`echo ${check} | egrep -o "Slot \w" | awk '{print $NF}' | grep -v "$excludeslot"`
else
slots=`echo ${check} | egrep -o "Slot \w" | awk '{print $NF}'`
fi
if [ "$DEBUG" = "1" ]; then
echo "### Get \"Slot\" & exclude slot not needed >>>\n"${slots}"\n"
fi
for slot in $slots
do
# Get "logicaldrive" for slot
check2b=`sudo -u root $hpacucli controller slot=$slot logicaldrive all show 2>&1`
status=$?
if test ${status} -ne 0; then
echo "RAID UNKNOWN - $hpacucli did not execute properly : "${check2b}
exit $STATE_UNKNOWN
fi
check2="$check2$check2b"
if [ "$DEBUG" = "1" ]; then
echo "### Get \"logicaldrive\" for slot >>>\n"${check2b}"\n"
fi
# Get "physicaldrive" for slot
if [ "$PHYSICAL_DRIVE" = "1" -o "$DEBUG" = "1" ]; then
check2b=`sudo -u root $hpacucli controller slot=$slot physicaldrive all show | sed -e 's/\?/\-/g' 2>&1 | grep "physicaldrive"`
else
check2b=`sudo -u root $hpacucli controller slot=$slot physicaldrive all show | sed -e 's/\?/\-/g' 2>&1 | grep "physicaldrive" | grep "\(Failure\|Failed\|Rebuilding\)"`
fi
status=$?
if [ "$PHYSICAL_DRIVE" = "1" -o "$DEBUG" = "1" ]; then
if test ${status} -ne 0; then
echo "RAID UNKNOWN - $hpacucli did not execute properly : "${check2b}
exit $STATE_UNKNOWN
fi
fi
check2="$check2$check2b"
if [ "$DEBUG" = "1" ]; then
echo "### Get \"physicaldrive\" for slot >>>\n"${check2b}"\n"
fi
done
# Get "Chassis" & exclude chassis not needed
if [ "$EXCLUDE_CH" = "1" ]; then
chassisnames=`echo ${check} | grep -v "in a scenario of" | egrep -o "in \w+" | egrep -v "Slot" | awk '{print $NF}' | grep -v "$excludech"`
else
chassisnames=`echo ${check} | grep -v "in a scenario of" | egrep -o "in \w+" | egrep -v "Slot" | awk '{print $NF}'`
fi
if [ "$DEBUG" = "1" ]; then
echo "### Get \"Chassis\" & exclude chassis not needed >>>\n"${chassisnames}"\n"
fi
for chassisname in $chassisnames
do
# Get "logicaldrive" for chassisname
check2b=`sudo -u root $hpacucli controller chassisname="$chassisname" logicaldrive all show 2>&1`
status=$?
if test ${status} -ne 0; then
echo "RAID UNKNOWN - $hpacucli did not execute properly : "${check2b}
exit $STATE_UNKNOWN
fi
check2="$check2$check2b"
if [ "$DEBUG" = "1" ]; then
echo "### Get \"logicaldrive\" for chassisname >>>\n"${check2b}"\n"
fi
# Get "physicaldrive" for chassisname
if [ "$PHYSICAL_DRIVE" = "1" -o "$DEBUG" = "1" ]; then
check2b=`sudo -u root $hpacucli controller chassisname="$chassisname" physicaldrive all show | sed -e 's/\?/\-/g' 2>&1 | grep "physicaldrive"`
else
check2b=`sudo -u root $hpacucli controller chassisname="$chassisname" physicaldrive all show | sed -e 's/\?/\-/g' 2>&1 | grep "physicaldrive" | grep "\(Failure\|Failed\|Rebuilding\)"`
fi
status=$?
if [ "$PHYSICAL_DRIVE" = "1" -o "$DEBUG" = "1" ]; then
if test ${status} -ne 0; then
echo "RAID UNKNOWN - $hpacucli did not execute properly : "${check2b}
exit $STATE_UNKNOWN
fi
fi
check2="$check2$check2b"
if [ "$DEBUG" = "1" ]; then
echo "### Get \"physicaldrive\" for chassisname >>>\n"${check2b}"\n"
fi
done
# Check STATUS
if [ "$DEBUG" = "1" ]; then
echo "### Check STATUS >>>"
fi
# Omit battery/capacitor/cache status check if requested
if [ "$EXCLUDE_BATTERY" = "1" ]; then
check=`echo "$check" | grep -v 'Battery/Capacitor Status: Failed (Replace Batteries/Capacitors)'`
check=`echo "$check" | grep -v 'Cache Status: Temporarily Disabled'`
fi
if echo ${check} | egrep Failed >/dev/null; then
echo "RAID CRITICAL - HP Smart Array Failed: "${check} | egrep Failed
exit $STATE_CRITICAL
elif echo ${check} | egrep Disabled >/dev/null; then
echo "RAID CRITICAL - HP Smart Array Problem: "${check} | egrep Disabled
exit $STATE_CRITICAL
elif echo ${check2} | egrep Failed >/dev/null; then
echo "RAID CRITICAL - HP Smart Array Failed: "${check2} | egrep Failed
exit $STATE_CRITICAL
elif echo ${check2} | egrep Failure >/dev/null; then
echo "RAID WARNING - Component Failure: "${check2} | egrep Failure
exit $STATE_WARNING
elif echo ${check2} | egrep Rebuild >/dev/null; then
echo "RAID WARNING - HP Smart Array Rebuilding: "${check2} | egrep Rebuild
exit $STATE_WARNING
elif echo ${check2} | egrep Recover >/dev/null; then
echo "RAID WARNING - HP Smart Array Recovering: "${check2} | egrep Recover
exit $STATE_WARNING
elif echo ${check} | egrep "Cache Status: Temporarily Disabled" >/dev/null; then
echo "RAID WARNING - HP Smart Array Cache Disabled: "${check}
exit $STATE_WARNING
elif echo ${check} | egrep FIRMWARE >/dev/null; then
echo "RAID WARNING - "${check}
exit $STATE_WARNING
else
if [ "$DEBUG" = "1" -o "$VERBOSE" = "1" ]; then
check3=`echo "${check}" | egrep Status`
check3=`echo ${check3}`
echo "RAID OK: "${check2}" ["${check3}"]"
else
echo "RAID OK"
fi
exit $STATE_OK
fi
exit $STATE_UNKNOWN