Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathplc2.py
116 lines (81 loc) · 3.11 KB
/
plc2.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
"""
swat-s1 plc2
"""
from minicps.devices import PLC
from utils import PLC2_DATA, STATE, PLC2_PROTOCOL
from utils import PLC_SAMPLES, PLC_PERIOD_SEC
from utils import IP
import time
import shlex
import subprocess
from cpppo.server.enip.get_attribute import proxy_simple
PLC1_ADDR = IP['plc1']
PLC2_ADDR = IP['plc2']
PLC3_ADDR = IP['plc3']
FIT201_2 = ('FIT201', 2)
class SwatPLC2(PLC):
def pre_loop(self, sleep=0.1):
print 'DEBUG: swat-s1 plc2 enters pre_loop'
print
time.sleep(sleep)
def main_loop(self):
"""plc2 main loop.
- read flow level sensors #2
- update interal enip server
"""
print 'DEBUG: swat-s1 plc2 enters main_loop.'
print
# TODO: stop original server from being hosted
# subprocess.Popen.kill()
# try:
# server.kill()
# except Exception as error:
# print 'ERROR stop enip server: ', error
# Start enip server with dummy values (to be updated for each "PLC_SAMPLE" loop)
tag_string = 'FIT201:2@22/1/1=REAL'
cmd = shlex.split(
'enip_server --print' +
' ' + tag_string
)
# print 'DEBUG enip _send cmd shlex list: ', cmd
# Start server in the background
try:
client = subprocess.Popen(cmd, shell=False)
# client.wait()
time.sleep(1) # wait for server to start
except Exception as error:
print 'ERROR plc2 error starting server: ', error
exit(1)
via = proxy_simple('192.168.1.20')
fit201_tag = '@22/1/1'
# with client.connector(host=PLC2_ADDR, port=44818) as conn:
# # Set the value of the tag
# tag_name = '@22/1/1'
# new_value = 10
# conn.write([(tag_name, new_value)])
count = 0
while(count <= PLC_SAMPLES):
fit201 = float(self.get(FIT201_2))
print "DEBUG PLC2 - get fit201: %f" % fit201
# self.send(FIT201_2, fit201, PLC2_ADDR) # updates value of fit201 hosted on PLC2's server (i think)
with via: result, = via.read([(fit201_tag + '=(REAL)' + str(fit201), fit201_tag)])
print 'this is the return value: %s' % result
# send_status = self.send(FIT201_2, fit201, PLC1_ADDR)
# if send_status == None or TypeError:
# print "\n\n\n\n\nDEBUG PLC2 - FAILED TO SEND FIT201 TO PLC1: FIT201_2 is not tuple\n\n\n\n\n"
# print "fit201: ", fit201
# else:
# print "\n\n\n\n\nDEBUG PLC2 - send fit201: %f\n\n\n\n\n" % fit201
# fit201 = self.receive(FIT201_2, PLC2_ADDR)
# print "DEBUG PLC2 - receive fit201: ", fit201
time.sleep(PLC_PERIOD_SEC)
count += 1
print 'DEBUG swat plc2 shutdown'
if __name__ == "__main__":
# notice that memory init is different form disk init
plc2 = SwatPLC2(
name='plc2',
state=STATE, # plc state, from sqlite database
protocol=PLC2_PROTOCOL,
memory=PLC2_DATA,
disk=PLC2_DATA)