radiance_measure requires glare sensor #93
Comments
To work with the case where there are none, looks like it should be
or the same construct as this one: openstudio-model-articulation-gem/lib/measures/radiance_measure/measure.rb Lines 1282 to 1283 in e304679
or move that inside that block that starts on L1282 actually |
This seems to work. It allows radiance to run without a glare sensor. |
I am not sure if this is an issue, but it appears that the radiance_measure requires a glare sensor to properly execute. If the OpenStudio model does not have a glare sensor installed, it will run radiance, but it seems the information is never passed to EnergyPlus for simulation.
The text was updated successfully, but these errors were encountered: