Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathhpe_oneview_synergy.rb
107 lines (97 loc) · 3.09 KB
/
hpe_oneview_synergy.rb
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
# coding: utf-8
#
# Copyright 2018 Chef Software, Inc.
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
chef_gem 'oneview-sdk' do
compile_time true
end
require 'oneview-sdk'
my_client = { url: 'https://ONEVIEW.example.com', user: 'Administrator', password: '*******', api_version: 500 }
# Create a new fiber channel network
oneview_fc_network 'FCNetwork1' do
data(
autoLoginRedistribution: true,
fabricType: 'FabricAttach'
)
client my_client
action :create
end
# Create a new fiber channel over ethernet network
oneview_fcoe_network 'FCoENetwork1' do
data(
vlanId: 2101,
bandwidth: {
typicalBandwidth: 2000,
maximumBandwidth: 9000,
}
)
associated_san 'VSAN2101'
client my_client
action :create
end
# Create a new ethernet network
oneview_ethernet_network 'EthernetNetwork1' do
client my_client
data(
vlanId: 1001,
purpose: 'General',
smartLink: false,
privateNetwork: false
)
end
# Create an enclosure group
oneview_enclosure_group 'EnclosureGroup1' do
data(
stackingMode: 'Enclosure',
portMappingCount: 8,
portMappings: [
{ midplanePort: 1, interconnectBay: 1 },
{ midplanePort: 2, interconnectBay: 2 },
{ midplanePort: 3, interconnectBay: 3 },
{ midplanePort: 4, interconnectBay: 4 },
{ midplanePort: 5, interconnectBay: 5 },
{ midplanePort: 6, interconnectBay: 6 },
{ midplanePort: 7, interconnectBay: 7 },
{ midplanePort: 8, interconnectBay: 8 },
],
interconnectBayMappingCount: 2,
interconnectBayMappings: [
{ interconnectBay: 3, logicalInterconnectGroupUri: '/rest/logical-interconnect-groups/02c6d1b0-e081-4da4-beb4-1991451ec5d4' },
{ interconnectBay: 6, logicalInterconnectGroupUri: '/rest/logical-interconnect-groups/02c6d1b0-e081-4da4-beb4-1991451ec5d4' },
],
ipAddressingMode: 'IpPool',
ipRangeUris: ['/rest/id-pools/ipv4/ranges/c8f08983-f55f-4894-99e5-497e57ff2081'],
powerMode: 'RedundantPowerFeed',
description: nil,
enclosureCount: 3,
associatedLogicalInterconnectGroups: ['/rest/logical-interconnect-groups/02c6d1b0-e081-4da4-beb4-1991451ec5d4']
)
logical_interconnect_groups ['MLAG-ImageStreamer']
client my_client
action :create
end
servers = 3
oneview_server_profile 'Chef-Node-1' do
client my_client
server_hardware 'BOT-CN75150107, bay 4'
server_hardware_type 'SY 480 Gen9 CNA Only'
enclosure_group 'EnclosureGroup1'
server_profile_template 'RedHat 7.3'
end
oneview_server_hardware 'BOT-CN75150107, bay 4' do
client my_client
power_state 'on'
# action [ :set_power_state, :update_ilo_firmware ]
action :set_power_state
end