Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathcontrol4_dimmer.groovy
149 lines (137 loc) · 5.4 KB
/
control4_dimmer.groovy
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
metadata {
definition(name: "Control4 Dimmer", namespace: "etrnls", author: "Shuai Wang") {
capability "Actuator"
capability "Sensor"
capability "Switch"
capability "Switch Level"
capability "Refresh"
capability "Health Check"
fingerprint endpointId: "01", profileId: "0104", inClusters: "0003"
}
}
def parse(String description) {
def evt = zigbee.getEvent(description)
if (evt) {
log.debug "parse event ${evt}"
return evt
}
if (description?.startsWith("catchall:")) {
def msg = zigbee.parse(description)
def data = msg.clusterId == 0x0001 ? new String(msg.data as byte[]) : ""
if (data.contains("sa c4.dmx.cc 01 01")) {
log.debug "parse switch on"
evt = createEvent(name: "switch", value: "on")
} else if (data.contains("sa c4.dmx.cc 05 01")) {
log.debug "parse switch off"
evt = createEvent(name: "switch", value: "off")
} else if (data.contains("sa c4.dmx.bp") || data.contains("sa c4.dmx.sc") ||
data.contains("sa c4.dmx.hc") || data.contains("sa c4.dmx.he") ||
data.contains("sa c4.dmx.cc")) {
// bp - button down
// sc - button up
// hc - button hold
// he - button hold end
// cc - button click
// params:
// 01 top button
// 05 bottom button
// bp 01 - top button down
// cc 05 02 - bottom button click twice
} else if (data.contains("sa c4.dmx.ls")) {
def level = zigbee.convertHexToInt(data.tokenize(" ")[5])
log.debug "parse level ${level}"
if (level >= 0 && level <= 100) {
evt = createEvent(name: "level", value: level)
} else {
log.error "parse level ${level} not within [0..100]"
}
} else if (data.contains("c4:control4_light:C4-APD120") ||
data.contains("c4:control4_light:C4-SW120277")) {
// firmware?
} else {
if (data.length() > 0 && data.charAt(data.length() - 1) == '\n') {
data = data.take(data.length() - 1)
}
log.warn "parse(data = '${data}' msg = '${msg}') not handled"
}
} else {
log.warn "parse(description = '${description}') not handled"
}
if (evt?.name == "level") {
if (evt.value == 0) {
return [evt, createEvent(name: "switch", value: "off")]
} else if (device.latestValue("switch") == "off") {
return [evt, createEvent(name: "switch", value: "on")]
}
}
evt
}
def on() {
log.trace "on()"
device.endpointId = 1
// zigbee.on() = [st cmd 0x${device.deviceNetworkId} 0x01 0x0006 0x01 {}, delay 2000]
// 0x01: endpointId
// 0x0006: zigbee On/Off cluster
// 0x01: put the light in the on state
zigbee.on()
}
def off() {
log.trace "off()"
device.endpointId = 1
// zigbee.off() = [st cmd 0x${device.deviceNetworkId} 0x01 0x0006 0x00 {}, delay 2000]
// 0x01: endpointId
// 0x0006: zigbee On/Off cluster
// 0x00: put the light in the off state
zigbee.off()
}
def setLevel(value) {
log.trace "setLevel(${value})"
device.endpointId = 1
def cmds = []
if (value == 0) {
cmds << off()
} else if (device.latestValue("switch") == "off") {
cmds << on()
}
def level = Math.round(value * 255 / 100);
// [st cmd 0x${device.deviceNetworkId} 0x01 0x0008 0x04 {<00~FF>0000}, delay 2000]
// 0x0008: zigbee Level Control cluster
// 0x04: set level
// "0000" is transition time
cmds << zigbee.command(0x0008, 0x04, zigbee.convertToHexString(level), "0000")
cmds
}
def configure() {
log.trace "configure()"
device.endpointId = 1
// zdo bind: zdo bind 0x${device.deviceNetworkId} <source endpoint> <dest endpoint> <cluster> <zigbee id>
// onOffConfig() = [
// zdo bind 0x${device.deviceNetworkId} 0x01 0x01 0x0006 {${device.zigbeeId}} {},
// delay 2000,
// st cr 0x${device.deviceNetworkId} 0x01 0x0006 0x0000 0x10 0x0000 0x0258 {},
// delay 2000]
// def onOffConfig(minReportTime=0, maxReportTime=600) {
// configureReporting(ONOFF_CLUSTER, 0x0000, DataType.BOOLEAN, minReportTime, maxReportTime, null)
// }
// levelConfig() = [
// zdo bind 0x${device.deviceNetworkId} 0x01 0x01 0x0008 {${device.zigbeeId}} {},
// delay 2000,
// st cr 0x${device.deviceNetworkId} 0x01 0x0008 0x0000 0x20 0x0001 0x0E10 {01},
// delay 2000]
// def levelConfig(minReportTime=1, maxReportTime=3600, reportableChange=0x01) {
// configureReporting(LEVEL_CONTROL_CLUSTER, 0x0000, DataType.UINT8, minReportTime, maxReportTime, reportableChange)
// }
// onOffRefresh() = [st rattr 0x${device.deviceNetworkId} 0x01 0x0006 0x0000, delay 2000]
// levelRefresh() = [st rattr 0x${device.deviceNetworkId} 0x01 0x0008 0x0000, delay 2000]
// zigbee.configureReporting(Integer Cluster, Integer attributeId, Integer dataType,
// Integer minReportTime, Integer MaxReportTime, [Integer reportableChange], Map additionalParams=[:])
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh()
}
def refresh() {
log.trace "refresh()"
configure()
}
def ping() {
log.trace "ping()"
refresh()
}